Axial flux permanent magnet synchronous motors (AFPMSMs) have been widely used in wind-power generation, electric vehicles, aircraft, and other renewable-energy applications owing to their high power density, operating efficiency, and integrability. To facilitate comprehensive research on AFPMSM, this article reviews the developments in the research on the design and control optimization of AFPMSMs. First, the basic topologies of AFPMSMs are introduced and classified. Second, the key points of the design optimization of core and coreless AFPMSMs are summarized from the aspects of parameter design, structure design, and material optimization. Third, because efficiency improvement is an issue that needs to be addressed when AFPMSMs are applied to electric or other vehicles, the development status of efficiency-optimization control strategies is reviewed. Moreover, control strategies proposed to suppress torque ripple caused by the small inductance of disc coreless permanent magnet synchronous motors (DCPMSMs) are summarized. An overview of the rotor-synchronization control strategies for disc contra-rotating permanent magnet synchronous motors (CRPMSMs) is presented. Finally, the current difficulties and development trends revealed in this review are discussed.
16 June 2021 in IEEE Transactions on Instrumentation and Measurement
Busbar current sensor without magnetic core is used more and more in compact power electronic equipment due to its small size and lightweight. The differential measurement technique is generally adopted to resist external magnetic interference. The sensitivity of busbar current sensors varies with the frequency of the sensed current due to the skin effect in the busbar. Traditional coreless busbar current sensors can accurately measure dc current, but the measurement error increases when sensing high-frequency ac current. A coreless sensor configuration based on four tunneling magnetoresistance (TMR) chips is proposed in this article with high measurement accuracy for both dc and high-frequency ac currents while eliminating the effect of magnetic stray field. An optimization method is introduced for the layout of the TMR chips around the busbar in order to obtain a current error below 1.5% up to 1 kHz. The effectiveness of the proposed sensor configuration and layout optimization method are verified by finite element simulation and prototype tests.
10 October 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
To achieve robust control against parameter variations for dual three-phase permanent magnet synchronous motor (DTP-PMSM), an improved model-free predictive current control (MFPCC) based on the ultra-local model is proposed in this paper. First, the parameter mismatch on conventional predictive control is analyzed, and it’s worth noting that the back-electromotive force (back EMF) harmonics have a huge impact on the current harmonics. Therefore, unlike the conventional schemes, the ultra-local model considering back EMF harmonics is employed to replace the fundamental and harmonic subspace current prediction models. Then, to meet the fast response and reduce chattering, a slide mode observer (SMO) based on improved reaching law is designed to estimate the disturbance and currents. And 12 virtual voltage vectors are synthesized for further suppressing currents in harmonic subspace. Finally, simulation and experimental results both show that the proposed method has the preferable robust performance and can reduce the phase current harmonics under parameter mismatches.
11 June 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
A predictive current control with parameter robustness (PR-PCC) method of permanent magnet synchronous motor (PMSM) is proposed in this article. First, a cost function is designed to calculate the increment of the optimal voltage vector at the current instant, which is based on incremental PMSM model. The incremental PMSM model is used to eliminate the influence of the motor flux parameter. Second, the optimal voltage vector that minimizes the cost function is obtained by combining the increment of the optimal voltage vector with the idea of iteration. At the same time, a current observer based on the incremental model is designed to compensate one-step sampling delay. In this way, the feedback current of $dq$ -axis accurately followed the reference current. In comparison with the conventional pulse width modulation predictive current control (PWM-PCC) method, the proposed method can significantly reduce the steady-state error of $dq$ -axis current caused by inductance, flux, and resistance parameters mismatch quickly. Finally, experimental results of the proposed method and the conventional PWM-PCC are presented in this article to verify the validity of the proposed method.
In this paper, an adaptive robust drive control system for an axial flux permanent magnet synchronous motor of an electric medium-sized bus based on the optimal torque distribution method is studied. The drive control system is mainly divided into two parts. First, a torque distribution method is proposed. The optimal torque distribution method based on particle swarm optimization algorithm is used to increase the high efficiency interval of the system and apply it to the energy feedback braking. Secondly, in order to reduce the nonlinear disturbance of the system and improve the accuracy of the unified control, this paper models and studies the vector system based on adaptive robust control. Finally, the whole drive control system is modeled, simulated and experimented. The simulation and experimental results show that the torque distribution method proposed in this paper can effectively increase the high-efficiency running time of the electric medium bus, and improve the shortcomings of insufficient mileage of the electric medium-sized bus. The use of a current controller based on adaptive robust control improves the control accuracy of the drive system and can effectively suppress the disturbances generated by it.
20 July 2022 in IEEE Transactions on Industrial Electronics
In surface-mounted permanent magnet synchronous motor (SPMSM) low-speed sensorless control, the high-frequency sinusoidal voltage injection method for rotor position estimation is affected by the low saturation salient rate of SPMSM and the system delay, resulting in estimation error. This article proposes a dual-demodulation method utilizing the high-frequency positive- and negative-sequence stator current of the motor. This method is based on the principle of maximizing the effect of the salient inductance component and minimizing the significant component of noise, which improves the utilization of the current containing angle information and increases the signal-to-noise ratio of the position angle error fed to the rotor position observer. The dc bias of the current caused by system delay is also eliminated so that the accuracy of position estimation is improved. The proposed method is verified by experiment, and the results show that the accuracy of the estimated rotor position and dynamic performance of the estimator is greatly improved compared to existing methods.