22 June 2023 in IEEE Access
Verified
Journal Article
Open access
GGGabriel Miguel Gomes Guerreiro
Gabriel Miguel Gomes Guerreiro
RSRanjan Sharma
Ranjan Sharma
FMFrank Martin
Frank Martin
PGPramod Ghimire
Pramod Ghimire
GYGuangya Yang
Guangya Yang
The calculation of short-circuit current contributions from full-converter based type IV wind turbines and other inverter-based power plants are often simplified. They are represented as simple fixed current sources for the steady-state stage of the fault during short-circuit evaluations. As wind power penetration increases, it becomes increasingly important to factor the details of short-circuit contribution from such inverter-based power plants for long-term planning as well as equipment and protection system design. The challenge lies in the fact that this type of inverter-based power plants is fully connected through power electronics, and their short-circuit contributions cannot be easily represented and calculated based on traditional physical laws developed for synchronous generators. This paper addresses the main challenges and limitations of the current accepted practices in the industry. The challenges are discussed for all three stages during a fault referring to the stages of more traditional power plants, namely sub-transient, transient and steady-state. An electromagnetic transient (EMT) model validated through field tests on a full-scale prototype wind turbine was used to simulate over 20,000 scenarios and examine the three stages in detail. Results show that during the sub-transient stage, in the first milliseconds of the fault, the converter exhibits a so-called quasi-voltage source behavior with high currents limited by transient hardware limitations and high negative sequence current injection for unbalanced faults, regardless of the current priority chosen. During the transient stage, the converter starts transitioning to a grid code/voltage-dependent current source until reaching the steady-state stage of the fault. This paper sheds light on various aspects of the three stages of the short-circuit and identifies novel behaviors and correlations through time-domain simulations and statistical analysis. At the end, it provides suggestions for best practices with EMT and analytical models, and possible future solutions and research.

13 February 2024 in IEEE Access
Verified
Journal Article
Open access
GGGabriel Miguel Gomes Guerreiro
Gabriel Miguel Gomes Guerreiro
FMFrank Martin
Frank Martin
TDThomas Dreyer
Thomas Dreyer
GYGuangya Yang
Guangya Yang
BABjörn Andresen
Björn Andresen
The rapid expansion of wind power needs increased efforts in establishing rules for connecting wind power plants (WPPs) through grid codes and standards. This makes grid compliance testing and model validation more complex for wind turbine generator (WTG) manufacturers and WPP developers. This paper explores various challenges and solutions within the wind industry concerning grid compliance and the integration of large-scale WPPs. Traditionally, WTG original equipment manufacturers (OEMs) conduct grid compliance tests on full-scale prototype turbines, while WPP developers predominantly engage in studies for new WPPs based on offline EMT and RMS simulations. Up to this point, these approaches have sufficed to ensure grid compliance for WTGs and WPPs. However, as the wind sector progresses, new testing methods are required to meet the growing WT capacity, WPP complexity, and deployment pace, aiming to achieve society’s sustainability targets. The industry is actively exploring methodologies that address these challenges by testing new turbine subsystems and components at the development level, employing software-/hardware-in-the-loop real-time simulation for WTG/WPP interoperability assessment, and ensuring control and protection performance verification during design and operation. Additionally, digital twin approaches are being considered, encompassing the entire development and operation chain for grid compliance and connection aspects. Ultimately, this paper presents a fresh overview of these strategies, outlining definitions and the pros/cons for the stakeholders involved in the process.

27 June 2024 in Electric Power Systems Research
Verified
Journal Article
Open access
GGGabriel M.G. Guerreiro
Gabriel M.G. Guerreiro
Ramon Abritta Aguiar SantosRamon Abritta Aguiar Santos
Ramon Abritta Aguiar Santos
KVKaio V. Vilerá
Kaio V. Vilerá
RSRanjan Sharma
Ranjan Sharma
FMFrank Martin
Frank Martin
GYGuangya Yang
Guangya Yang
Given the increasing penetration of converter-interfaced resources in power systems, properly estimating the short-circuit current (SCC) contribution in large networks has become a growing challenge and necessity to ensure the security and stability of the systems and assets. This paper presents two novel methods to estimate the SCC contribution of type IV wind turbines at both the transient and steady-state stages of unbalanced and balanced faults: (1) a machine learning-based method trained with electromagnetic transient (EMT) simulations and capable of estimating some of the initial peak and transient current magnitudes; (2) an analytical approach to estimate the steady-state SCC based on the voltage and grid code dependency of the converter during the fault. The methods are coupled into a single framework and compared to field-validated EMT models of a real turbine. The results show that the majority of the estimated currents in the transient stages present errors below 5%. In steady-state, the errors are not greater than 1.21%. Given the complexity of the problem, these margins may be deemed acceptable for short-circuit studies.

25 February 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
GGGabriel Miguel Gomes Guerreiro
Gabriel Miguel Gomes Guerreiro
RSRanjan Sharma
Ranjan Sharma
FMFrank Martin
Frank Martin
NGNikolaus Goldenbaum
Nikolaus Goldenbaum
GYGuangya Yang
Guangya Yang
This letter presents a field-verified passive method to estimate the equivalent fundamental frequency grid impedance. The method requires reactive power, active power, and root-mean-square voltage measurements as inputs and is based on a mathematical derivation independent of the angle and frequency estimation. A thorough verification process was adopted, comprising simulations in EMT utilizing a wind turbine with actual control code, field wind turbine measurements, and an operational wind power plant where the transmission system operator agreed to change grid configurations to allow testing of the algorithm for two grid scenarios. Results show good agreement between expectations and estimation from the proposed method.

10 July 2025 in IEEE Power and Energy Magazine
Verified
Journal Article
Closed access
NMNilesh Modi
Nilesh Modi
MFMartin Fecteau
Martin Fecteau
LULukas Unruh
Lukas Unruh
GGGabriel M. Gomes Guerreiro
Gabriel M. Gomes Guerreiro
JRJonathan Rose
Jonathan Rose
QZQiang Zhang
Qiang Zhang
Electromagnetic transient (EMT) models are becoming vital for understanding the power systems performance with growing penetrations of inverter-based resources (IBR). However, without appropriate model testing and validation, the accuracy of the power system analysis is far from guaranteed. A thorough model examination process that utilizes a combination of approaches to ensure model accuracy, robustness, and usability provides confidence in the EMT models and the outcome of the power system assessment using these models. Model testing ensures that the model is of good quality, numerically robust and has ability to appropriately represent plant's response to various operating conditions. During the model testing phase, a large number of simulation tests are applied to the model to check its usability, quality, performance, and consistency. While model testing provides confidence in the usability of the model, the accuracy of the model can be achieved through model validation process. There are various stages of model life cycle where model validation can be carried out using various approaches. Each stage of model validation has its own advantages and disadvantages. These approaches are generally divided in three categories: validating a single plant in a single-machine infinite-bus configuration, validating the full-scale system model consisting of many plants, and validating either a single plant or a group of plants using hardware-in-the-loop setup. When evaluating EMT models and validation outcomes, it is important to apply engineering judgment along with other metrics such as error tolerances and accuracy bands. Both model acceptance testing and validation are not straightforward and require time and resources, however, adequate and accurate models provide confidence to power system planners and operators to develop the power system operating envelope.

12 March 2026 in IEEE Open Access Journal of Power and Energy
Verified
Journal Article
Open access
Ramon Abritta Aguiar SantosRamon Abritta Aguiar Santos
Ramon Abritta Aguiar Santos
GGGabriel M. G. Guerreiro
Gabriel M. G. Guerreiro
APAlexey Pavlov
Alexey Pavlov
BBBørre Tore Børresen
Børre Tore Børresen
Elisabetta TedeschiElisabetta Tedeschi
Elisabetta Tedeschi
IJIvo C. da Silva Junior
Ivo C. da Silva Junior
The generator side of inverter-based resources (IBRs) interfaced with back-to-back converters is electrically decoupled from the grid. During electrical faults, grid-following IBRs behave as voltage-dependent current sources due to grid code requirements and converter control. This paper presents Newton-Raphson formulations for estimating short-circuit currents from IBRs using novel power flow modeling approaches to address voltage-dependent current sources. The work shows how to represent dq0 current injections, which are typically implemented in control architectures based on phase-locked loops. The power flow formulations are adapted to capture grid codes with different characteristics, such as the injection of negative-sequence currents during unbalanced faults. Comparisons against a field-validated electromagnetic transients (EMT) model reveal mean absolute errors of less than 0.5% for the proposed approach when estimating steady-state short-circuit currents from type IV wind turbine generators under grid-following control.