Kaio Vinicius Vilera

Kaio Vinicius Vilera

Auto-generated profile, based on publicly available information

Kaio Vinicius Vilera

Technical University of Denmark (DTU), Denmark

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Energies
Verified
Journal Article
Open access
PDF file
STSilvio Antonio Teston
Silvio Antonio Teston
KVKaio Vinicius Vilerá
Kaio Vinicius Vilerá
MMMarcello Mezaroba
Marcello Mezaroba
CRCassiano Rech
Cassiano Rech
This paper proposes a control system for the single-phase Three-Ports Active Neutral- Point-Clamped (ANPC-3P) converter, which can inject a sinusoidal current into the grid, balance the neutral point voltage, and regulate the energy storage system (ESS) current with reduced low-frequency ripple. Despite other applications, ANPC-3P inverter can be used in grid-tied renewable generation to allow the simultaneous connection of a photovoltaic (PV) energy source and an ESS to the AC grid. The ESS is connected directly to the inverter circuit without any auxiliary DC-DC converter, but due to the DC bus pulsed power, it can be subjected to low-frequency current ripple. This undesired current ripple is difficult to filter and can lead to shorter battery life. A control system based on well-known controllers is analyzed and designed. Theoretical analysis is validated experimentally using a single-phase 1-kW prototype.

20 March 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
GSGabriel Avila Saccol
Gabriel Avila Saccol
KVKaio Vinícius Vilerá
Kaio Vinícius Vilerá
Fernanda CarnieluttiFernanda Carnielutti
Fernanda Carnielutti
CRCassiano Rech
Cassiano Rech
Cascaded H-bridge converters are interesting candidates for photovoltaic (PV) and energy storage systems, since PV panels and/or batteries can be directly connected to the input dc-side of each converter module. However, differences in the parameters of the batteries or variable ambient conditions may result in energy imbalances among the power modules. In these cases, conventional modulation strategies will lead to an increased distortion on the converter output voltage. Therefore, this paper proposes a generalized space vector modulation for single-phase cascaded H-bridge converters considering the power processed by each power module and maintaining a low-THD multilevel output voltage waveform. The proposed method improves the converter output voltage harmonic spectrum compared to the conventional phase-shifted modulation strategy in cases of power imbalance among modules. Experimental results are included to demonstrate the performance of the proposed method.

27 June 2024 in Electric Power Systems Research
Verified
Journal Article
Open access
GGGabriel M.G. Guerreiro
Gabriel M.G. Guerreiro
Ramon Abritta Aguiar SantosRamon Abritta Aguiar Santos
Ramon Abritta Aguiar Santos
KVKaio V. Vilerá
Kaio V. Vilerá
RSRanjan Sharma
Ranjan Sharma
FMFrank Martin
Frank Martin
GYGuangya Yang
Guangya Yang
Given the increasing penetration of converter-interfaced resources in power systems, properly estimating the short-circuit current (SCC) contribution in large networks has become a growing challenge and necessity to ensure the security and stability of the systems and assets. This paper presents two novel methods to estimate the SCC contribution of type IV wind turbines at both the transient and steady-state stages of unbalanced and balanced faults: (1) a machine learning-based method trained with electromagnetic transient (EMT) simulations and capable of estimating some of the initial peak and transient current magnitudes; (2) an analytical approach to estimate the steady-state SCC based on the voltage and grid code dependency of the converter during the fault. The methods are coupled into a single framework and compared to field-validated EMT models of a real turbine. The results show that the majority of the estimated currents in the transient stages present errors below 5%. In steady-state, the errors are not greater than 1.21%. Given the complexity of the problem, these margins may be deemed acceptable for short-circuit studies.

1 December 2019
Verified
Conference Paper
Closed access
KVKaio Vinicius Vilera
Kaio Vinicius Vilera
CRCassiano Rech
Cassiano Rech
STSilvio Antonio Teston
Silvio Antonio Teston
This paper investigates the neutral-point (NP) voltage balancing problem from the perspective of the space vector modulation for different operating conditions of the recently proposed Three-ports Active Neutral-Point-Clamped (ANPC-3P) topology, which can integrate one energy storage system per inverter leg. Some scenarios to reduce the low-frequency voltage ripple in the NP are analyzed and the effects on the NP current due to the integration are reported. Theoretical propositions were validated by simulation results.