14 January 2014 in Rapid Prototyping Journal
Purpose: – The purpose of this paper is to describe a manufacturing methodology for a wrist orthosis. The case study aims to offer new approaches in the area of human orthoses. Design/methodology/approach: – The article describes the utilization of rapid prototyping (RP), passive stereo photogrammetry and software tools for the orthosis design process. This study shows the key points of the design and manufacturing methodology. The approach uses specific technologies, such as 3D digitizing, reverse engineering and polygonal-surface software, FDM RP and 3D printing. Findings: – The results show that the used technologies reflect the patient's requirements and also they could be an alternative solution to the standard method of orthosis design. Research limitations/implications: – The methodology provides a good position for further development issues. Practical implications: – The methodology could be usable for clinical practice and allows the manufacturing of the perfect orthosis of the upper limb. The usage of this methodology depends on the RP system and type of material. Originality/value: – The article describes a particular topical problem and it is following previous publications in the field of human orthoses. The paper presents the methodology of wrist orthosis design and manufacturing. The paper presents an alternative approach applicable in clinical practice.
1 August 2010 in Tribology International
20 July 2011 in Medical Engineering & Physics
The finite element analysis (FEA) has been identified as a useful tool for the stress and strain behaviour determination in lower limb prosthetics. The residual limb and prosthetic socket interface was the main subject of interest in previous studies. This paper focuses on the finite element analysis for the evaluation of structural behaviour of the Sure-flex™ prosthetic foot and other load-bearing components. A prosthetic socket was not included in the FEA. An approach for the finite element modelling including foot analysis, reverse engineering and material property testing was used. The foot analysis incorporated ground reaction forces measurement, motion analysis and strain gauge analysis. For the material model determination, non-destructive laboratory testing and its FE simulation was used. A new, realistic way of load application is presented along with a detailed investigation of stress distribution in the load-bearing components of the prosthesis. A novel approach for numerical and experimental agreement determination was introduced. This showed differences in the strain on the pylon between the experimental and the numerical model within 30% for the anteroposterior bending and up to 25% for the compression. The highest von Mises stresses were found on the foot-pylon connecting component at toe off. Peak stress of 216MPa occurred on the posterior adjusting screw and maximum stress of 156MPa was found at the neck of the male pyramid.
1 November 2011 in Tribology International
23 August 2018 in European Journal of Trauma and Emergency Surgery
7 January 2014 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
The aim of this study is to consider the relevance of in situ measurements of bovine serum film thickness in the optical test device that could be related to the function of the artificial hip joint. It is mainly focussed on the effect of the hydrophobicity or hydrophilicity of the transparent surface and the effect of its geometry. Film thickness measurements were performed using ball-on-disc and lens-on-disc configurations of optical test device as a function of time. Chromatic interferograms were recorded with a high-speed complementary metal-oxide semiconductor digital camera and evaluated with thin film colorimetric interferometry. It was clarified that a chromium layer covering the glass disc has a hydrophobic behaviour which supports the adsorption of proteins contained in the bovine serum solution, thereby a thicker lubricating film is formed. On the contrary, the protein film formation was not observed when the disc was covered with a silica layer having a hydrophilic behaviour. In this case, a very thin lubricating film was formed only due to the hydrodynamic effect. Metal and ceramic balls have no substantial effect on lubricant film formation although their contact surfaces have relatively different wettability. It was confirmed that conformity of contacting surfaces and kinematic conditions has fundamental effect on bovine serum film formation. In the ball-on-disc configuration, the lubricant film is formed predominantly due to protein aggregations, which pass through the contact zone and increase the film thickness. In the more conformal ball-on-lens configuration, the lubricant film is formed predominantly due to hydrodynamic effect, thereby the film thickness is kept constant during measurement.