Purpose: – The purpose of this paper is to describe a manufacturing methodology for a wrist orthosis. The case study aims to offer new approaches in the area of human orthoses. Design/methodology/approach: – The article describes the utilization of rapid prototyping (RP), passive stereo photogrammetry and software tools for the orthosis design process. This study shows the key points of the design and manufacturing methodology. The approach uses specific technologies, such as 3D digitizing, reverse engineering and polygonal-surface software, FDM RP and 3D printing. Findings: – The results show that the used technologies reflect the patient's requirements and also they could be an alternative solution to the standard method of orthosis design. Research limitations/implications: – The methodology provides a good position for further development issues. Practical implications: – The methodology could be usable for clinical practice and allows the manufacturing of the perfect orthosis of the upper limb. The usage of this methodology depends on the RP system and type of material. Originality/value: – The article describes a particular topical problem and it is following previous publications in the field of human orthoses. The paper presents the methodology of wrist orthosis design and manufacturing. The paper presents an alternative approach applicable in clinical practice.
This paper deals with various selective laser melting (SLM) processing strategies for aluminum 2618 powder in order to get material densities and properties close to conventionally-produced, high-strength 2618 alloy. To evaluate the influence of laser scanning strategies on the resulting porosity and mechanical properties a row of experiments was done. Three types of samples were used: single-track welds, bulk samples and samples for tensile testing. Single-track welds were used to find the appropriate processing parameters for achieving continuous and well-shaped welds. The bulk samples were built with different scanning strategies with the aim of reaching a low relative porosity of the material. The combination of the chessboard strategy with a 2 × 2 mm field size fabricated with an out-in spiral order was found to eliminate a major lack of fusion defects. However, small cracks in the material structure were found over the complete range of tested parameters. The decisive criteria was the elimination of small cracks that drastically reduced mechanical properties. Reduction of the thermal gradient using support structures or fabrication under elevated temperatures shows a promising approach to eliminating the cracks. Mechanical properties of samples produced by SLM were compared with the properties of extruded material. The results showed that the SLM-processed 2618 alloy could only reach one half of the yield strength and tensile strength of extruded material. This is mainly due to the occurrence of small cracks in the structure of the built material.
The finite element analysis (FEA) has been identified as a useful tool for the stress and strain behaviour determination in lower limb prosthetics. The residual limb and prosthetic socket interface was the main subject of interest in previous studies. This paper focuses on the finite element analysis for the evaluation of structural behaviour of the Sure-flex™ prosthetic foot and other load-bearing components. A prosthetic socket was not included in the FEA. An approach for the finite element modelling including foot analysis, reverse engineering and material property testing was used. The foot analysis incorporated ground reaction forces measurement, motion analysis and strain gauge analysis. For the material model determination, non-destructive laboratory testing and its FE simulation was used. A new, realistic way of load application is presented along with a detailed investigation of stress distribution in the load-bearing components of the prosthesis. A novel approach for numerical and experimental agreement determination was introduced. This showed differences in the strain on the pylon between the experimental and the numerical model within 30% for the anteroposterior bending and up to 25% for the compression. The highest von Mises stresses were found on the foot-pylon connecting component at toe off. Peak stress of 216MPa occurred on the posterior adjusting screw and maximum stress of 156MPa was found at the neck of the male pyramid.
The Co-Cr-Mo alloy is a biomaterial with very good corrosion resistance and wear resistance; thus, it is widely applied for knee replacements. The wear resistance is influenced by the amount of hcp phase and morphology of carbidic precipitates, which can both be altered by heat treatment. This study compares a conventional knee replacement manufactured by investment casting with a material prepared by the progressive technology of 3D printing. The first set of results shows a different response of both materials in increasing hardness with annealing at increasing temperatures up to the transformation temperature. Based on these results, solution treatment and subsequent aging at conditions to reach the maximum hardness was applied. Microstructural changes were studied thoroughly by means of optical, scanning electron and transmission electron microscopy. While increased hardness in the conventional material is caused by the precipitation of fine hard carbides combined with an increase in the hcp phase by isothermal transformation, a massive fcc → hcp transformation is the main cause for the hardness increase in the 3D-printed material.