Vijay Katkar

Vijay Katkar

Auto-generated profile, based on publicly available information

Vijay Katkar

Department of Computer Engineering, Marwadi University, Rajkot, Gujarat, India

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in IEEE Access
Verified
Journal Article
Open access
Shobhit K. PatelShobhit K. Patel
Shobhit K. Patel
JSJaymit Surve
Jaymit Surve
VKVijay Katkar
Vijay Katkar
Juveriya ParmarJuveriya Parmar
Juveriya Parmar
Fahad Al-ZahraniFahad Al-Zahrani
Fahad Al-Zahrani
Francis BuiFrancis Bui
Francis Bui
We have investigated graphene-based three various refractive index sensors (split ring resonator (SRR), split ring resonator with thin wire (SRRTW), and thin wire (TW) refractive index sensors) for the encoding and sensing-based applications. The sensors are designed to detect the presence of hemoglobin biomolecules with high sensitivity. The results are analyzed in the form of transmittance, and electric field and detailed sensitivity analysis is also carried out for the proposed graphene-based refractive index sensors for four various concentrations of hemoglobin biomolecules. We have also investigated the sensor’s performance in terms of quality factor, Q, and figure of merit (FOM). The encoding of ‘0’ and ‘1’ is attained by varying the graphene chemical potential fulfilling the one-digit coding. An array of these sensors can then be used for encoding-based applications. The detailed analysis of reported sensors is also carried out by checking the effect of varying physical parameters such as substrate thickness, split ring gap, and thin wire width on tunability. These sensors can be applied in biomedical or encoding-based applications. Experiments are performed using XGBoost regressor to determine, whether simulation time and resources can be reduced by using regression analysis to predict the transmittance values of intermediate frequency or not. Experimental results prove that regression analysis using XGBoost Regressor can reduce the simulation time and resources by at least 70 percent.

2 March 2022 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
Juveriya ParmarJuveriya Parmar
Juveriya Parmar
Shobhit K. PatelShobhit K. Patel
Shobhit K. Patel
VKVijay Katkar
Vijay Katkar
ANAyyanar Natesan
Ayyanar Natesan
Rapid detection of mycobacterium tuberculosis bacteria is very important in reducing tuberculosis disease. We propose a label-free graphene-based refractive index sensor using a machine learning approach that detects mycobacterium tuberculosis bacteria. The biosensor is designed for higher sensitivity by analyzing different parameters like substrate thickness, resonator thickness, and angle of incidence. Machine learning is applied to predict the values of absorption for different wavelengths. The machine learning model is applied to four different parameters (angle of incidence, substrate thickness, resonator thickness, graphene chemical potential) of the biosensor. The plus shape metasurface is placed above the graphene-SiO2 hybrid layer to improve the sensitivity. The comparative analysis with other published designs is also presented. The proposed sensor with its higher sensitivity and ability to detect mycobacterium tuberculosis bacteria can be used in biomedical devices for diagnostic applications. Experiments are performed to check the K-Nearest Neighbors (KNN)-regressor model’s prediction efficiency for predicting absorption values of intermediate wavelengths. Different values of K and two test cases; R-50, U-50 are used to test the regressor models using the R2 Score as an evaluation metric. It is observed from the experimental results that, high prediction efficiency can be achieved using lower values of K in the KNN-Regressor model.

26 August 2022 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
Shobhit K. PatelShobhit K. Patel
Shobhit K. Patel
JSJaymit Surve
Jaymit Surve
Juveriya ParmarJuveriya Parmar
Juveriya Parmar
ANAyyanar Natesan
Ayyanar Natesan
VKVijay Katkar
Vijay Katkar
Machine learning is the latest approach to optimize the performance of absorbers, sensors, etc. A sensor with behavior prediction using polynomial regression is presented. Three different variations of metasurfaces namely double split-ring resonator, single split ring resonator, split ring resonator with thin wire are analyzed. The proposed design aims to achieve the highest sensitivity by observing different designs and different parameter variation. The highest sensitivity is achieved for double split-ring resonator and single split ring resonator designs. The change in thickness of different parameter affect the absorption and the highest sensitivity is calculated based on these variations. The polynomial regression (PR) model is employed to predict the absorption values for assorted combinations of intermediate wavelength values with angle variation, substrate thickness, substrate length, substrate width, graphene potential, and resonator thickness values. Test Cases R-30 and R-50 are evaluated using R2 score metric to assess the effectiveness of PR model for predicting the values of absorption. R2 score close to 1.0 is achieved for all the experiments at a higher (more than 5) polynomial degree, which proves the prediction efficiency of a regression model. The proposed biosensor designed with a PR model can be applied in biomedical applications for hemoglobin detection.


4 March 2024 in Discover Artificial Intelligence
Verified
Journal Article
Open access
PDF file
CVCharmy Vora
Charmy Vora
VKVijay Katkar
Vijay Katkar
MLMunindra Lunagaria
Munindra Lunagaria
In past several decades, gait biometrics has emerged as a viable alternative to traditional identification methods, offering advancements in surveillance, monitoring, and analysis techniques. However, determining gender based on gait remains a challenge, particularly in computer vision applications. This study proposes a robust and adaptable approach to address this issue by leveraging gait analysis. There is a growing need for datasets tailored to gait analysis and recognition to facilitate the extraction of relevant data. While most existing research relies on image-based gait datasets, this study utilizes the OULP-Age dataset from OU-ISIR, representing gait through gait energy images (GEIs). The methodology involves feature extraction from GEIs using pre-trained models, followed by classification with the XGBoost classifier. Gender prediction is enhanced through parameter fine-tuning of the XGBoost classifier. Comparative analysis of 11 pre-trained models for feature extraction reveals that DenseNet models, combined with optimized XGBoost parameters, demonstrate promising results for gender prediction. This study contributes to advancing gender prediction based on gait analysis and underscores the efficacy of integrating deep learning models with traditional classifiers for improved accuracy and reliability.