1 October 2021 in Journal of Applied Geodesy
Since the development of GNSS techniques, the determination of a precise quasi-geoid model has become even more actual. In terms of this project the staff of the Institute of Geodesy and Geoinformatics (GGI) has developed a new quasi-geoid model based on DFHRS (Digital Finite-element Height Reference Surface) approach additionally using astrogeodetic measurements - vertical deflections (VD), which can be observed by a Digital zenith camera. This paper evaluates a quasi-geoid model results based on vertical deflections, as a study area using the territory of Latvia: the standard deviation of the solution is equal to 0.006 m with observation residuals after the adjustment of minimum and maximum differences - 0.012 and 0.012 accordingly. The standard deviation of quasi-geoid heights and h-H values from LGIA database is equal to 0.012 m with minimum and maximum differences - 0.026 and 0.025 accordingly. The post-processed terrestrial VD observations have been compared to VD derivatives from EGM2008 and GGMplus geopotential models. The developed quasi-geoid has been compared to the national quasi-geoid model LV'14 and to the Scandinavian NKG2015.
25 October 2017 in IOP Conference Series: Materials Science and Engineering
Over several years the Institute of Geodesy and Geoinformatics (GGI) was engaged in the design and development of a digital zenith camera. At the moment the camera developments are finished and tests by field measurements are done. In order to check these data and to use them for geoid model determination DFHRS (Digital Finite element Height reference surface (HRS)) v4.3. software is used. It is based on parametric modelling of the HRS as a continous polynomial surface. The HRS, providing the local Geoid height N, is a necessary geodetic infrastructure for a GNSS-based determination of physcial heights H from ellipsoidal GNSS heights h, by H=h-N. The research and this publication is dealing with the inclusion of the data of observed vertical deflections from digital zenith camera into the mathematical model of the DFHRS approach and software v4.3. A first target was to test out and validate the mathematical model and software, using additionally real data of the above mentioned zenith camera observations of deflections of the vertical. A second concern of the research was to analyze the results and the improvement of the Latvian quasi-geoid computation compared to the previous version HRS computed without zenith camera based deflections of the vertical. The further development of the mathematical model and software concerns the use of spherical-cap-harmonics as the designed carrier function for the DFHRS v.5. It enables - in the sense of the strict integrated geodesy approach, holding also for geodetic network adjustment - both a full gravity field and a geoid and quasi-geoid determination. In addition, it allows the inclusion of gravimetric measurements, together with deflections of the vertical from digital-zenith cameras, and all other types of observations. The theoretical description of the updated version of DFHRS software and methods are discussed in this publication.
25 October 2017 in IOP Conference Series: Materials Science and Engineering
The GNSS reference station ellipsoidal heights are of the mm precision quality due to their continuous operation and monitoring of their coordinates in the international terrestrial reference frame. The GNSS reference station data is mostly used for rover positioning. The reference stations are very important also as a fitting points for the geoid modelling developments. Unfortunately, the importance of the referencing of antenna heights to the national levelling network are sometimes neglected. Usually the antennas are fixed on the roof of high buildings in urban environment. It is quite difficult to make a high precision levelling procedures and sometimes the direct geodetic measurements of antenna normal heights are not performed. Actually, for the most of Latvian GNSS reference network antennas the normal heights are not tied to the national levelling network. The aim of this research is to use the collected data of GNSS/levelling points for the determination of the normal heights of continuously operating reference station antennas.
2 November 2015 in IOP Conference Series: Materials Science and Engineering
There is an urgent necessity for a highly accurate and reliable geoid model to enable prompt determination of normal height with the use of GNSS coordinate determination due to the high precision requirements in geodesy, building and high precision road construction development. Additionally, the Latvian height system is in the process of transition from BAS- 77 (Baltic Height System) to EVRS2007 system. The accuracy of the geoid model must approach the precision of about ~1 cm looking forward to the Baltic Rail and other big projects. The use of all the available and verified data sources is planned, including the use of enlarged set of GNSS/levelling data, gravimetric measurement data and, additionally, the vertical deflection measurements over the territory of Latvia. The work is going ahead stepwise. Just the issue of GNSS reference network stability is discussed. In order to achieve the ~1 cm precision geoid, it is required to have a homogeneous high precision GNSS network as a basis for ellipsoidal height determination for GNSS/levelling points. Both the LatPos and EUPOS® - Riga network have been examined in this article.
2 November 2015 in IOP Conference Series: Materials Science and Engineering
The GPS observations of both Latvian permanent GNSS networks - EUPOS®-Riga and LatPos, have been collected for a period of 8 years - from 2007 to 2014. Local surface displacements have been derived from the obtained coordinate time series eliminating different impact sources. The Bernese software is used for data processing. The EUREF Permanent Network (EPN) stations in the surroundings of Latvia are selected as fiducial stations. The results have shown a positive tendency of vertical displacements in the western part of Latvia - station heights are increasing, and negative velocities are observed in the central and eastern parts. Station vertical velocities are ranging in diapason of 4 mm/year. In the case of horizontal displacements, site velocities are up to 1 mm/year and mostly oriented to the south. The comparison of the obtained results with data from the deformation model NKG_RF03vel has been made. Additionally, the purpose of this study is to analyse GPS time series obtained using two different data processing strategies: Precise Point Positioning (PPP) and estimation of station coordinates relatively to the positions of fiducial stations also known as Differential GNSS.
1 November 2023 in Journal of Surveying Engineering