1 February 2019 in Medicine
Optimizing surgical instrumentation may contribute to value-based care, particularly in commonly performed procedures. We report our experience in implementing a perioperative efficiency program in 2 types of orthopedic surgery (primary total-knee arthroplasty, TKA, and total-hip arthroplasty, THA). A comparative before-and-after study with 2 participating surgeons, each performing both THA and TKA, was conducted. Our objective was to evaluate the effect of surgical tray optimization on operating and processing time, cost, and waste associated with preparation, delivery, and staging of sterile surgical instruments. The study was designed as a prospective quality improvement initiative with pre- and postimplementation operational measures and a provider satisfaction survey. A total of 96 procedures (38 preimplementation and 58 postimplementation) were assessed using time-stamped performance endpoints. The number and weight of trays and instruments processed were reduced substantially after the optimization intervention, particularly for TKA. Setup time was reduced by 23% (6 minutes, P = .01) for TKA procedures but did not differ for THA. The number of survey respondents was small, but satisfaction was high overall among personnel involved in implementation. Optimizing instrumentation trays for orthopedic procedures yielded reduction in processing time and cost. Future research should evaluate patient outcomes and incremental/additive impact on institutional quality measures.
23 June 2022 in Spine Deformity
Purpose: To assess surgical and safety outcomes associated with different rod materials and diameters in adolescent idiopathic scoliosis (AIS) surgery. Methods: A systematic literature review and meta-analysis evaluated the surgical management of AIS patients using pedicle screw fixation systems (i.e., posterior rods and pedicle screws) with rods of different materials and sizes. Postoperative surgical outcomes (e.g., kyphosis and coronal correction) and complications (i.e., hyper/hypo-lumbar lordosis, proximal junctional kyphosis, revisions, reoperations, and infections) were assessed. Random-effects models (REMs) pooled data for outcomes reported in ≥ 2 studies. Results: Among 75 studies evaluating AIS surgery using pedicle screw fixation systems, 46 described rod materials and/or diameters. Two studies directly comparing titanium (Ti) and cobalt–chromium (CoCr) rods found that CoCr rods provided significantly better postoperative kyphosis angle correction vs. Ti rods during a shorter follow-up (0–3 months, MD = − 2.98°, 95% CI − 5.79 to − 0.17°, p = 0.04), and longer follow-up (≥ 24 months, MD = − 3.99°, 95% CI − 6.98 to − 1.00, p = 0.009). Surgical infection varied from 2% (95% CI 1.0–3.0%) for 5.5 mm rods to 4% (95% CI 2.0–7.0%) for 6 mm rods. Reoperation rates were lower with 5.5 mm rods 1% (95% CI 0.0–3.0%) vs. 6 mm rods [6% (95% CI 2.0–9.0%); p = 0.04]. Differences in coronal angle, lumbar lordosis, proximal junctional kyphosis, revisions, and infections did not differ significantly (p > 0.05) among rods of different materials or diameters. Conclusion: For AIS, CoCr rods provided better correction of thoracic kyphosis compared to Ti rods. Patients with 5.5 mm rods had fewer reoperations vs. 6.0 and 6.35 mm diameter rods. Level of evidence: III.
1 March 2010 in Eating and Weight Disorders - Studies on Anorexia, Bulimia and Obesity
29 July 2022 in Spine Deformity
Purpose: To assess clinical and safety outcomes associated with different rod materials and diameters in adult spinal deformity (ASD) surgery. Methods: A systematic literature review and meta-analysis evaluated ASD surgery using pedicle screw fixation systems with rods of different materials and sizes. Postoperative outcomes (i.e., Cobb, sagittal vertical axis, and pelvic tilt angle) and complications (i.e., pseudarthrosis and rod breakage) were assessed. Random effects models (REMs) pooled data for outcomes reported in ≥ 2 studies. Results: Among 50 studies evaluating ASD surgery using pedicle screw fixation systems, 17 described rod material/diameter. Postoperative outcomes did not statistically differ between cobalt–chromium (CoCr) vs. titanium (Ti) rods (n = 2 studies; mean [95% confidence interval (CI)] sagittal vertical axis angle: CoCr 37.00° [18.58°–55.42°] and Ti 32.58° [24.62°–40.54°]; mean [95% CI] pelvic tilt angle: CoCr 26.20° [22.87°–29.53°] and Ti 20.15° [18.0°–22.31°]). The pooled proportion (95% CI) of pseudarthrosis was 15% (7–22%) for CoCr and 12% (− 8–32%) for stainless steel (SS) (n = 2 studies each; Chi2 = 0.07, p = 0.79). The pooled proportion (95% CI) of broken rods was 12% (1–22%) for Ti (n = 3 studies) and 10% (2–19) for CoCr (n = 1 study). Among 6.0–6.35 mm rods, the pooled (95% CI) postoperative Cobb angle (n = 2) was 12.01° (9.75°–14.28°), sagittal vertical axis angle (n = 4) was 35.32° (30.02°–40.62°), and pelvic tilt angle was 21.11° (18.35°–23.86°). Conclusions: For ASD patients undergoing posterior fixation and fusion, there are no statistically significant differences in postoperative outcomes or complications among rods of varying materials and diameters. Benchmark postsurgical outcomes and complication rates by rod material and diameter are provided. Level of Evidence: III
1 January 2019 in Geriatric Orthopaedic Surgery & Rehabilitation
Hip fractures are common and costly in the elderly population, often contributing to loss of function and independence. Prompt, coordinated surgical care may improve clinical and economic outcomes for this population. We created an interdisciplinary care program focused on minimizing time spent immobilized awaiting surgery and streamlining the care pathway for hip fracture. Patients older than 65 years with any hip fracture type including hip fracture repair Diagnosis-Related Group codes (MS-DRG 480, 481, or 482) and MS-DRG 469 and 470 with a hip fracture diagnosis were included in the study. The Hip Fracture Care program (HFCP) was implemented on a staggered basis in 3 hospitals in the HonorHealth system. Time to surgery, length of stay, and discharge location (home/skilled nursing facility) were compared pre- and post-intervention, utilizing an interrupted time series analysis to account for background trends. More than 2000 patients across the 3 facilities received HFCP care; demographics were similar for the 826 patients serving as the pre-implementation comparison group. Mean (standard deviation [SD]) length of stay decreased from 5.6 (4.0) to 4.7 (2.9) days (mean difference 0.9 days; P < .05). Mean (SD) time from admission to the operating room decreased from 30.8 (21.1) to 25.6 (20.5) hours (mean difference 5.2 hours; P < .05). There was no change in the proportion of patients discharged to home versus skilled nursing facility. Optimal care of this vulnerable population can significantly reduce the time to surgery and length of stay. Length of stay was reduced by nearly 1 day with implementation of a multifactorial program for hip fracture care.
6 October 2014 in Leadership in Health Services
Purpose: – This paper aims to present a two-decade effort to improve team functioning and patient outcomes in inpatient stroke rehabilitation settings.Design/methodology/approach: – The principal improvement effort was conducted over a nine-year period in 50 Veterans Administration Hospitals in the USA. A comprehensive team-based model was developed and tested in a series of empirical studies. A leadership development intervention was used to improve team functioning, and a follow-up cluster-randomized trial documented patient outcome improvements associated with the leadership training.Findings: – Iterative team and leadership improvements are presented in summary form, and a set of practice-proven development observations are derived from the results. Details are also provided on the leadership training intervention that improved teamwork processes and resulted in improvements in patient outcomes that could be linked to the intervention itself.Research limitations/implications: – The practice-proven development observations are connected to leadership development theory and applied in the form of suggestions to improve leadership development and teamwork in a broad array of medical treatment settings.Practical implications: – This paper includes suggestions for leadership improvement in medical treatment settings using interdisciplinary teams to meet the customized needs of the patient populations they serve.Originality/value: – The success of the team effectiveness model and the team-functioning domains provides a framework and best practice for other health care organizations seeking to improve teamwork effectiveness.