1 January 2015 in Journal of Conservative Dentistry
Background: There is a growing interest about electronic apex locators for working length determination. There are several studies dealing with their performance in different conditions. Aims: The aim of this study is to evaluate the accuracy of Root ZX and Raypex 6 in teeth with different apical diameters. Materials and Methods: Actual working length (AWL) of 80 single rooted teeth were determined as 0.5 mm short of apical foramen. The teeth were divided into 4 groups (n = 20). First group (G 0) included teeth with mature apices. Root canals of the other groups (G 32, G 57 and G 72) were enlarged until apical sizes of 0.32, 0.57 and 0.72 mm were obtained. Samples were embedded in alginate and electronic measurements (EM) were performed. Statistical analysis: was achieved with Fisher exact test. Results: Both devices revealed a high rate of success in G 0 and G 32. Their accuracy decreased significantly in G 57 and G 72 groups (P < 0.05). Intra-group results of Root ZX and Raypex 6 were similar (P > 0.05). Conclusions: Root ZX and Raypex 6 are reliable in teeth with mature apices. At foramen diameters exceeding 0.57 mm, their accuracy is susceptible.
1 January 2021 in Journal of Dental Sciences
During root canal preparation apical extrusion is an undesirable situation that can cause postoperative complications. The aim of the present study is to evaluate the effect of the presence of different chelators in root canals during preparation on the amount of apically extruded debris and to investigate the effect of surface tension of irrigant on the apical extrusion. Ninety extracted mandibular incisor teeth were included. Prior to canal preparation, the teeth were mounted to Eppendorf tubes. Root canals of the samples were prepared with Reciproc instruments in the presence of different chelating agents (17% EDTA-liquid, 17% EDTA-gel, 7% maleic acid, 2.25% peracetic acid, 10% citric acid) and 5% NaOCl. Apically extruded debris was collected in Eppendorf tubes and weighted with an electronic balance. The surface tension of solutions was calculated with the ring method using a du Noüy ring digital tensiometer. The statistical analysis was performed with Tamhane's T2 test for apical extrusion and the Tukey for surface tension. The correlation between apical extrusion and surface tension was compared using Pearson's coefficient. The least amount of apically extruded debris was with EDTA-gel, peracetic acid and citric acid which were similar to each other. NaOCl had the highest surface tension whereas peracetic acid and EDTA-liquid had the lowest. There was no significant correlation exists between apical extrusion and surface tension. The presence of EDTA-gel, citric acid and peracetic acid in root canals during preparation decreased the amount of apically extruded debris compared to other solutions. The investigated irrigation solutions have no significant effect on the amount of apical debris extrusion.
1 January 2017 in Journal of Conservative Dentistry
Background: Canal transportation is a common sequel caused by rotary instruments. Aims: The purpose of the present study is to evaluate the degree of transportation after the use of Reciproc single-file instruments with or without glide path files. Methods: Thirty resin blocks with L-shaped canals were divided into three groups (n = 10). Group 1 - canals were prepared with Reciproc-25 file. Group 2 - glide path file-G1 was used before Reciproc. Group 3 - glide path files-G1 and G2 were used before Reciproc. Pre- and post-instrumentation images were superimposed under microscope, and resin removed from the inner and outer surfaces of the root canal was calculated throughout 10 points. Results: Statistical analysis was performed with Kruskal–Wallis test and post hoc Dunn test. For coronal and middle one-thirds, there was no significant difference among groups (P > 0.05). For apical section, transportation of Group 1 was significantly higher than other groups (P < 0.05). Conclusion: Using glide path files before Reciproc single-file system reduced the degree of apical canal transportation.
1 March 2017 in Journal of Dental Sciences
Extrusion of intracanal bacteria leads to treatment failures. Compare the apical extrusion of intracanal bacteria (Enterococcus faecalis) during canal preparation with three different instrumentation techniques [RECIPROC, One Shape (OS), and Twisted-File Adaptive (TFA)] with different motion types. Ninety teeth with different canal morphologies were divided into three main groups, each including 30 teeth (10 mandibular incisors, 10 mandibular premolars, and 10 curved roots). Roots were resected until 13-mm working length was obtained and fixed to glass vials filled with brain-heart infusion broth. Each canal was filled with E. faecalis suspension. The three main groups were further grouped into three subgroups. Each group was further subgrouped into three, with each subgroup including 10 roots from each type of teeth (10 incisors/subgroup, 10 premolars/subgroup, and 10 curved canals/subgroup). These subgroups were prepared with one of RECIPROC, OS, or TFA. Bacterial colonies extruded into each vial were incubated in brain-heart infusion agar at 37°C for 5 days and counted using a colony counter as the number of colony-forming units per milliliter. Statistical analyses were performed using one-way analysis of variance, post hoc Tukey honest significant difference, and Kruskal-Wallis tests. Apically extruded bacteria were not statistically different from each other (P > 0.05). The amount of apically extruded bacteria was statistically similar for both different instruments in the same type of tooth (P > 0.05) and same instrument in different types of teeth (P > 0.05). Neither the motion type of instrument nor the canal morphology affected the degree of bacterial extrusion.
1 January 2019 in Journal of Oral Science
The present study aimed to evaluate the degree of crack formation during canal preparation using reciprocating files. A total of 120 incisor teeth were divided into eight groups according to irrigation protocol (n = 15). The irrigation solution and chelating agents included distilled water, sodium hypochlorite (NaOCl), citric acid, maleic acid, peracetic acid, ethylenediaminetetraacetic acid (EDTA) gel, and EDTA liquid. The root canals were prepared using reciprocating instruments while one of the agents was present within the root canals. A control group was subjected to neither preparation nor irrigation. The roots were horizontally sectioned 3, 6, and 9 mm away from the apices. The numbers of cracks were recorded. Statistical analyses were performed using a chi-squared test. The chelating agents resulted in similar numbers of cracked sections. The use of one of the chelating agents during preparation using reciprocating instruments appears to be beneficial in reducing crack formation.
18 December 2023 in European Journal of Therapeutics
Objective: One of the most studied topics in electronic apex locators (EALs) is the effect of root canal condition on the accuracy of EALs. In this study, the accuracy of Root ZX Mini, Raypex 6, and Apex ID in detecting root perforation was evaluated in a dry environment and in the presence of saline, ethylenediamine tetraacetic acid (EDTA), and sodium hypochlorite (NaOCl) solutions. Methods: The mesiobuccal roots of 64 human maxillary first molars were selected for the study. These root canals were perforated from buccal root surface using a #1 Freze Beutherlock Peeso to form a 0.4 mm cavity. After perforation, the area where #40 K type file appeared was recorded as the actual length (AL) and the length measured by EAL devices both in dry canals and in the presence of solutions was recorded as the electronic measurement (EL). All electronic measurements were statistically compared with the actual length. Results: All EALs achieved AL-consistent results on EL measures. Consistency was determined using Root ZX Mini measurements in dry canals and canals irrigated with saline. The consistency of EL and AL conducted with Raypex 6 and Apex ID in canals irrigated with NaOCl, saline, and EDTA was found. There was a statistically significant difference in ELs with irrigation solutions among all EALs (p0.05). A consistency was discovered between ELs generated with the Root ZX Mini and ALs in both dry and saline-irrigated canals. Consistency was observed between ELs measured with Raypex 6 and Apex ID and ALs in canals irrigated with NaOCl, saline, and EDTA. Conclusion: The accuracy rates of the EALs used in this research were 97%–100% in the 1 mm range and 83%–92% in the 0.5 mm range. Despite the fact that ALs and ELs differed statistically significantly at the 0.05 level, these variations weren't thought to be clinically relevant. In the presence of conditions with different electro conductors, EALs from different generations may be used safely, and in a range of canal situations, these devices can yield measurements that are most similar to the AL.