Malcolm Durkin

Malcolm Durkin

Auto-generated profile, based on publicly available information

Malcolm Durkin

University of Colorado

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MDMalcolm Durkin
Malcolm Durkin
JAJoseph S. Adams
Joseph S. Adams
SBSimon R. Bandler
Simon R. Bandler
JCJames A. Chervenak
James A. Chervenak
SCSaptarshi Chaudhuri
Saptarshi Chaudhuri
BYBetty A. Young
Betty A. Young
Time-division multiplexing (TDM) is the backup readout technology for the X-ray Integral Field Unit (X-IFU), a 3168-pixel X-ray transition-edge sensor (TES) array that will provide imaging spectroscopy for european space agency's Athena satellite mission. X-IFU design studies are considering readout with a multiplexing factor of up to 40. We present data showing 40-row TDM readout (32 TES rows + 8 repeats of the last row) of TESs that are of the same type as those being planned for X-IFU, using measurement and analysis parameters within the ranges specified for X-IFU. Single-column TDM measurements have best-fit energy resolution of (1.91 ± 0.01) eV for the Al Kα complex (1.5 keV), (2.10 ± 0.02) eV for Ti Kα (4.5 keV), (2.23 ± 0.02) eV for Mn Kα (5.9 keV), (2.40 ± 0.02) eV for Co Kα (6.9 keV), and (3.44 ± 0.04) eV for Br Kα (11.9 keV). Three-column measurements have best-fit resolution of (2.03 ± 0.01) eV for Ti Kα and (2.40 ± 0.01) eV for Co Kα. The degradation due to the multiplexed readout ranges from 0.1 eV at the lower end of the energy range to 0.5 eV at the higher end. The demonstrated performance meets X-IFU's energy-resolution and energy-range requirements. True 40-row TDM readout, without repeated rows, of kilopixel scale arrays of X-IFU-like TESs is now under development.

24 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
SSStephen J. Smith
Stephen J. Smith
JAJoseph S. Adams
Joseph S. Adams
SBSimon R. Bandler
Simon R. Bandler
SBSophie Beaumont
Sophie Beaumont
JCJames A. Chervenak
James A. Chervenak
MWMichael C. Witthoeft
Michael C. Witthoeft
Future X-ray astrophysics experiments require multiplexed readout of high fill-factor, kilo-pixel arrays of transition-edge sensors (TESs), with very high spectral resolution over a broad range of energies. In this paper we report on a prototype kilo-pixel array of Mo/Au TESs readout with 8-column by 32-row time-division multiplexing (TDM). This system is being used to demonstrate the critical detector and readout technology for ESA's Athena X-IFU, and when complete will be used in laboratory astrophysics experiments. Our array and TDM readout have demonstrated a combined full-width-at-half-maximum energy resolution, including > 200 pixels, of: 1.95 eV for Ti-Kα (4.5 keV), 1.97 eV for Mn-Kα (5.9 keV), 2.16 eV for Co-Kα (6.9 keV), 2.33 eV for Cu-Kα (8 keV), 3.26 eV for Br-Kα (11.9 keV). The 1 sigma statistical errors are ≤0.01 eV for all spectra. These results meet the broad-band resolution requirements for X-IFU with margin.

16 June 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
RHRuslan Hummatov
Ruslan Hummatov
ALAdriana E. Lita
Adriana E. Lita
TFTannaz Farrahi
Tannaz Farrahi
NONegar Otrooshi
Negar Otrooshi
SFSamuel Fayer
Samuel Fayer
SNSae Woo Nam
Sae Woo Nam
Photon-number resolving transition-edge sensors (TESs) with near unity system detection efficiency enable novel approaches to quantum computing, for example, heralding robust Gottesman–Kitaev–Preskill qubit states. Increasing the speed of the detectors increases the rate at which these states can be heralded. In addition, depending on the details of the scheme, faster detectors can reduce the complexities of the hardware implementation. In previous work, we demonstrated that adding a small amount of gold between the tungsten film and silicon substrate can increase thermal conductance and reduce detector recovery time. In that study, the readout electronics imposed limitations on stable biasing conditions of the TES detector, and the TES could only be biased at higher than ideal values. In this report, we demonstrate the operation of the TES illuminated by a heavily attenuated pulsed laser running at 1 MHz repetition rate and examine the limits to adding gold to speed up device recovery times using a higher bandwidth readout system. The best performance was achieved by combining a 15×15μm2 tungsten TES with 5μm3 of gold, which resulted in a recovery time faster than 250 ns, with an energy resolution of 0.25 eV full-width at half maximum at 0.8 eV photon energy.

4 April 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MDMalcolm Durkin
Malcolm Durkin
SBScott Backhaus
Scott Backhaus
SBSimon R. Bandler
Simon R. Bandler
JCJames A. Chervenak
James A. Chervenak
EDEd V. Denison
Ed V. Denison
NWNicholas A. Wakeham
Nicholas A. Wakeham
Time-division multiplexing (TDM) of transition-edge-sensor (TES) microcalorimeters is being developed as the readout technology for the Athena X-ray integral field unit (X-IFU) and CMB-S4. We present an experimental demonstration of our latest TDM architecture, which has been implemented in a 4-column × 34-row chip that is fully compatible with the X-IFU design specifications. This new “mux21” architecture is designed for differential readout and uses two-layer switches to reduce the number of row-address lines while also incorporating changes that reduce power to roughly 40% and the total number of SQUIDs to half that of TDM chips used in previous publications. With the 160 ns row durations specified for X-IFU, we obtained (2.02 ± 0.03) eV FWHM energy resolution at 5.9 keV in 2-column × 34-row TDM readout of a NASA X-IFU-like TES array, which meets the requirements of X-IFU's energy-resolution budget. Finally, a scaling analysis of our improved TDM readout chain to bolometer applications indicates that multiplexing factors on the scale of several hundred are possible, depending on the readout requirements.

17 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PSPaul Szypryt
Paul Szypryt
DBDouglas A. Bennett
Douglas A. Bennett
WBWilliam J. Boone
William J. Boone
ADAmber L. Dagel
Amber L. Dagel
GDGabriella Dalton
Gabriella Dalton
JWJason W. Wheeler
Jason W. Wheeler
Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of $\sim$ 1 $\mu$ m. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

11 March 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MDMalcolm Durkin
Malcolm Durkin
JAJoseph S. Adams
Joseph S. Adams
SBSimon R. Bandler
Simon R. Bandler
JCJames A. Chervenak
James A. Chervenak
EDEdward V. Denison
Edward V. Denison
NWNicholas Wakeham
Nicholas Wakeham
Time division multiplexing (TDM) is being developed as the readout technology of the X-ray integral field unit (X-IFU), a 3,168-pixel X-ray transition-edge sensor (TES) imaging spectrometer that is part of the European Space Agency's Athena satellite mission. Recent improvements in the low X-ray event count rate performance of TDM have been driven by increases in multiplexer bandwidth and the mitigation of settling transients. These methods and design changes have improved the 32-row multiplexed resolution of a NASA LPA 2.5a array from an initial (2.73 ± 0.03) eV to (1.97 ± 0.01) eV resolution at 5.9 keV. We discuss these recent advances in TDM readout, which have been implemented in an 8-column × 32-row spectrometer that will be deployed at the Lawrence Livermore National Laboratory electron beam ion trap (EBIT) facility, and present a model that will inform the design of future systems.