Ivan Sikirić

Ivan Sikirić

Auto-generated profile, based on publicly available information

Ivan Sikirić

Department of Cardiovascular Diseases, Division of Arrhythmias, University Hospital of Split, Split, Croatia

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
AAAnte Anić
Ante Anić
TPThomas Phlips
Thomas Phlips
TBToni Brešković
Toni Brešković
VMVikramaditya Mediratta
Vikramaditya Mediratta
SGSteven Girouard
Steven Girouard
JVJohan Vijgen
Johan Vijgen
BACKGROUND: Pulsed field ablation (PFA) is a promising treatment for atrial fibrillation. We report 1-year freedom from atrial arrhythmia outcomes using monopolar PFA delivered through 3 commercial, contact force–sensing focal catheters. METHODS: ECLIPSE AF (Safety & Clinical Performance Study of Catheter Ablation With the Centauri System for Patients With Atrial Fibrillation; NCT04523545) was a prospective, single-arm, multicenter study evaluating acute and chronic safety and performance using the CENTAURI system to deliver focal PFA with TactiCath SE, StablePoint, and ThermoCool ST. Patients with paroxysmal or persistent atrial fibrillation underwent pulmonary vein (PV) isolation under deep sedation or general anesthesia and returned for remapping at 90 days to evaluate chronic durability. Freedom from atrial arrhythmia was evaluated continuously through 12 months using standard rhythm monitoring for symptomatic episodes and 24-hour Holter at 6 and 12 months. RESULTS: Eighty-two patients (74% male, 51.2% paroxysmal, and 58.5% deep sedation) were treated. PV isolation was achieved in 100% of targeted veins (322/322) with first-pass isolation in 92.2% (297/322). There were 4 primary safety events in 4 patients (4.9%, 4/82); 1 nonembolic stroke due to exacerbated cardiac tamponade secondary to catheter perforation and 3 hemorrhagic vascular access complications. There were no incidences of adverse event fistula, diaphragmatic paralysis, myocardial infarction, pericarditis, thromboembolism, PV stenosis, transient ischemic attack, or death. Eighty patients (98%) underwent remapping. Optimized PFA cohorts 3, 4, and 5 showed per-patient isolation rates of 60%, 73%, and 81% and per-PV isolation rates of 84%, 90%, and 92%, respectively. One-year freedom from atrial arrhythmia was 80.2% (95% CI, 69.7%–87.4%) for the entire patient sample, including 41 patients who underwent repeat focal PFA with the CENTAURI system at remapping. CONCLUSIONS: This study demonstrated that optimization of focal PFA with 3 contact force–sensing, solid-tip ablation catheters resulted in the progressive improvement of PV isolation durability at 3-month remapping and high freedom from atrial arrhythmia survival rates, providing a promising focal PFA treatment option integrated with current ablation workflows.

27 May 2024 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
LKLucija Lisica Kordić
Lucija Lisica Kordić
ZJZrinka Jurisic
Zrinka Jurisic
TBToni Brešković
Toni Brešković
ISIvan Sikirić
Ivan Sikirić
JKJosip Katic
Josip Katic
AAAnte Anić
Ante Anić
Introduction: The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long‐term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter.Methods: Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long‐term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24‐h Holter ECGs at 3, 6, and 12 months postablation; and 12‐lead ECGs recorded during symptomatic episodes or visits.Results: Half of the patients had ls‐PerAF, and half had a history of catheter ablation—mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low‐voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow‐up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months.Conclusion: PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.

29 January 2024 in Journal of Interventional Cardiac Electrophysiology
Verified
Journal Article
Open access
PDF file
ISIvan Sikiric
Ivan Sikiric
ZJZrinka Jurisic
Zrinka Jurisic
TBToni Breskovic
Toni Breskovic
MJMarina Juric-Paic
Marina Juric-Paic
NBNina Berovic
Nina Berovic
AAAnte Anic
Ante Anic



24 May 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
AAA Anic
A Anic
TBT Breskovic
T Breskovic
ZJZrinka Jurisic
Zrinka Jurisic
ISI Sikiric
I Sikiric
JKJosip Katic
Josip Katic
SDS Doshi
S Doshi
Background/Introduction: Pulsed field ablation (PFA) is emerging as a safe and effective alternative energy modality for cardiac ablation. Data have shown that while tissue contact is critical for PFA, the amount of contact force is less important. Single-shot catheters have shown comparable results to current thermal methods for pulmonary vein isolation (PVI), however, are limited to anatomical-based ablation strategies and have limited ability to detect tissue contact. The investigational QuickShot™ large-area focal catheter (Galvanize Therapeutics, Redwood City, CA) combines high-density mapping with large-area focal ablation guided by contact detection. Purpose: The QuickShot PEF-AF study was a prospective, single-arm, first-in-human study performed at a single European center to evaluate the safety and performance of the QuickShot catheter (see Figure 1, panel A) combined with the CE-marked CENTAURI™ System (Galvanize Therapeutics, Figure 1, panel B) for catheter ablation of atrial fibrillation (AF). Methods: Subjects with paroxysmal or persistent AF underwent a PVI procedure under deep sedation (fentanyl, midazolam, propofol) guided by Rhythmia™ HDx (Boston Scientific, Marlborough, MA, Figure 1, panel D). Irrigation was set to a constant 6 mL/min during the procedure. Focal, monopolar, biphasic PFA lesions were delivered asynchronously at 33 Amps and a 10 mm inter-lesion spacing (center to center with 10 mm lesion tag size). Catheter-tissue contact was confirmed by ICE/fluoroscopy and a novel impedance-based contact detection system (Figure 1, panel C). The acute performance endpoint was PVI, assessed by entrance and exit block using high-density mapping. Procedural safety assessments included microbubble detection via ICE, induction of VT/VF, muscle stimulation, phrenic nerve function, and NIHSS post-procedure. Results: Twenty (20) subjects (60% PAF, 60 ± 12 years, 75% male, 4.3 ± 0.52 cm LA AP diameter) were enrolled and treated. Acute PVI was achieved in 100% of patients and targeted PVs (82/82), with first-pass isolation in 88% of targeted PVs. The PVI time was 31 ± 10 min with 46.7 ± 11.4 PFA applications. There were no device- or procedure-related adverse events, and no documented incidence of microbubble formation, arrhythmia induction, muscle stimulation, phrenic nerve dysfunction, esophageal injury, or change in NIHSS post-procedure. Conclusion: The QuickShot catheter enables safe and effective large-area focal PFA for subjects requiring PVI. The catheter design enables efficient and flexible focal lesion placement with the ability to ensure adequate apposition to targeted tissues using its novel contact detection algorithm. Future studies will investigate the use of this novel catheter for PFA strategies beyond PVI.