Toni Brešković

Toni Brešković

Auto-generated profile, based on publicly available information

Toni Brešković

Department of Cardiovascular Diseases, Division of Arrhythmias, University Hospital of Split, Split, Croatia

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AAAnte Anić
Ante Anić
TPThomas Phlips
Thomas Phlips
TBToni Brešković
Toni Brešković
PKPieter Koopman
Pieter Koopman
SGSteven Girouard
Steven Girouard
JVJohan Vijgen
Johan Vijgen
Aims: Pulsed field ablation (PFA) has emerged as a promising alternative to thermal ablation for treatment of atrial fibrillation (AF). We report performance and safety using the CENTAURI™ System (Galvanize Therapeutics) with three commercial, focal ablation catheters. Methods and results: ECLIPSE AF (NCT04523545) was a prospective, single-arm, multi-centre study evaluating safety and acute and chronic pulmonary vein isolation (PVI) durability using the CENTAURI System in conjunction with the TactiCath SE, StablePoint, and ThermoCool ST ablation catheters. Patients with paroxysmal or persistent AF were treated at two centres. Patients were analysed in five cohorts based upon ablation settings, catheter, and mapping system. Pulsed field ablation was performed in 82 patients (74% male, 42 paroxysmal AF). Pulmonary vein isolation was achieved in 100% of pulmonary veins (322/322) with first-pass isolation in 92.2% (297/322). There were four serious adverse events of interest (three vascular access complications and one lacunar stroke). Eighty patients (98%) underwent invasive remapping. Pulsed field ablation development Cohorts 1 and 2 showed a per-patient isolation rate of 38% and 26% and a per-PV isolation rate of 47% and 53%, respectively. Optimized PFA Cohorts 3–5 showed a per-patient isolation rate of 60%, 73%, and 81% and a per-PV isolation rate of 84%, 90%, and 92%, respectively. Conclusion: ECLIPSE AF demonstrated that optimized PFA using the CENTAURI System with three commercial, contact force-sensing, solid-tip focal ablation catheters resulted in transmural lesion formation and high proportion of durable PVI with a favourable safety profile, thus providing a viable treatment option for AF that integrates with contemporary focal ablation workflows.

1 January 2025 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
AAAnte Anić
Ante Anić
TPThomas Phlips
Thomas Phlips
TBToni Brešković
Toni Brešković
VMVikramaditya Mediratta
Vikramaditya Mediratta
SGSteven Girouard
Steven Girouard
JVJohan Vijgen
Johan Vijgen
BACKGROUND: Pulsed field ablation (PFA) is a promising treatment for atrial fibrillation. We report 1-year freedom from atrial arrhythmia outcomes using monopolar PFA delivered through 3 commercial, contact force–sensing focal catheters. METHODS: ECLIPSE AF (Safety & Clinical Performance Study of Catheter Ablation With the Centauri System for Patients With Atrial Fibrillation; NCT04523545) was a prospective, single-arm, multicenter study evaluating acute and chronic safety and performance using the CENTAURI system to deliver focal PFA with TactiCath SE, StablePoint, and ThermoCool ST. Patients with paroxysmal or persistent atrial fibrillation underwent pulmonary vein (PV) isolation under deep sedation or general anesthesia and returned for remapping at 90 days to evaluate chronic durability. Freedom from atrial arrhythmia was evaluated continuously through 12 months using standard rhythm monitoring for symptomatic episodes and 24-hour Holter at 6 and 12 months. RESULTS: Eighty-two patients (74% male, 51.2% paroxysmal, and 58.5% deep sedation) were treated. PV isolation was achieved in 100% of targeted veins (322/322) with first-pass isolation in 92.2% (297/322). There were 4 primary safety events in 4 patients (4.9%, 4/82); 1 nonembolic stroke due to exacerbated cardiac tamponade secondary to catheter perforation and 3 hemorrhagic vascular access complications. There were no incidences of adverse event fistula, diaphragmatic paralysis, myocardial infarction, pericarditis, thromboembolism, PV stenosis, transient ischemic attack, or death. Eighty patients (98%) underwent remapping. Optimized PFA cohorts 3, 4, and 5 showed per-patient isolation rates of 60%, 73%, and 81% and per-PV isolation rates of 84%, 90%, and 92%, respectively. One-year freedom from atrial arrhythmia was 80.2% (95% CI, 69.7%–87.4%) for the entire patient sample, including 41 patients who underwent repeat focal PFA with the CENTAURI system at remapping. CONCLUSIONS: This study demonstrated that optimization of focal PFA with 3 contact force–sensing, solid-tip ablation catheters resulted in the progressive improvement of PV isolation durability at 3-month remapping and high freedom from atrial arrhythmia survival rates, providing a promising focal PFA treatment option integrated with current ablation workflows.

16 March 2024 in Heart Rhythm
Verified
Journal Article
Closed access
TBToni Brešković
Toni Brešković
LLLucija Lisica
Lucija Lisica
ZJZrinka Jurišić
Zrinka Jurišić
DPDavor Petrović
Davor Petrović
ISIvan Sikirić
Ivan Sikirić
AAAnte Anić
Ante Anić

4 July 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
AAAnte Anic
Ante Anic
DBDarija DARIJA BAKOVIĆ Bakovic
Darija DARIJA BAKOVIĆ Bakovic
ZJZrinka Jurisic
Zrinka Jurisic
MFMichal Miroslaw Farkowski
Michal Miroslaw Farkowski
LLLucija Lisica
Lucija Lisica
JCJulian Chun
Julian Chun
Aims: Patients with atrial fibrillation who despite taking oral anti-coagulant therapy (OAT) suffer a stroke or systemic embolism (SSE) without vascular cause or who develop left atrial appendage (LAA) thrombus (LAAT) should be considered as having malignant LAA. The optimal treatment strategy to reduce SSE risk in such patients is unknown. The aim of the study is to investigate the diagnostic and therapeutic pathways for malignant LAA practiced in European cardiac centres.Methods and results: An 18-item online questionnaire on malignant LAA was disseminated by the European Heart Rhythm Association (EHRA) Scientific Initiatives Committee. A total of 196 physicians participated in the survey. There seems to be high confidence in transoesophageal echocardiography (TEE) imaging, considering LAAT diagnosis. Switching to another direct oral anti-coagulant (DOAC) is the preferred initial step for the treatment of malignant LAA followed by a switch to vitamin K antagonist (VKA), low-molecular-weight heparin, or continued/optimized DOAC dosage, whereas LAA closure is the last option. Left atrial appendage closure is a viable option in patients with embolic stroke despite OAT and no evidence of thrombus at TEE (empty LAA) after comprehensive diagnostic measures to exclude other sources of embolism.Conclusion: This EHRA survey provides a snapshot of the contemporary management of patients diagnosed with malignant LAA. Currently, the majority of patients are treated on an outpatient basis with either shifting from VKA to DOAC or from one DOAC to another. Left atrial appendage closure in this population seems to be reserved for patients with higher bleeding risk or complications of malignant LAA, such as stroke.

27 May 2024 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
LKLucija Lisica Kordić
Lucija Lisica Kordić
ZJZrinka Jurisic
Zrinka Jurisic
TBToni Brešković
Toni Brešković
ISIvan Sikirić
Ivan Sikirić
JKJosip Katic
Josip Katic
AAAnte Anić
Ante Anić
Introduction: The unique safety profile of pulsed field ablation (PFA) has made pulmonary vein isolation (PVI) + left atrial posterior wall (LAPW) ablation promising for treating persistent atrial fibrillation (PerAF). The goal of this study was to assess long‐term freedom from atrial fibrillation, atrial flutter, and atrial tachycardia (AF/AFL/AT), as well as the safety and feasibility of LAPW PFA using multipolar, pentaspline Farawave catheter.Methods: Retrospective observational study at a single institution. Data for 94 patients were collected from a prespecified intraprocedural registry. The long‐term AF/AFL/AT recurrence assessment was based on an analysis of medical history; 24‐h Holter ECGs at 3, 6, and 12 months postablation; and 12‐lead ECGs recorded during symptomatic episodes or visits.Results: Half of the patients had ls‐PerAF, and half had a history of catheter ablation—mostly RF PVI. The acute ablation success rate was 100%, and the primary safety outcome was observed in 2 patients. Fifty patients experienced AF/AFL/AT recurrence (54.3%). An increase in LAPW low‐voltage areas and AF classification were associated with arrhythmia recurrence. After a median follow‐up of 13 months, the Kaplan‒Meier estimated median time free of AF/AFL/AT after a single procedure was 14.7 months.Conclusion: PFA PVI + PWA had the best outcome in perAF patients without extensive LA fibrosis. AF recurrence was paroxysmal in significant part of the cohort. The addition of PWA to PVI using multipolar PFA was safe and did not significantly influence the transpired ablation time.

Verified
Journal Article
Open access
PDF file
JKJosip Katic
Josip Katic
ZJZrinka Jurisic
Zrinka Jurisic
Marko KumricMarko Kumric
Marko Kumric
Josip Andelo BorovacJosip Andelo Borovac
Josip Andelo Borovac
AAAnte Anic
Ante Anic
Josko BozicJosko Bozic
Josko Bozic
The autonomic nervous system is crucial in initiating and maintaining atrial fibrillation (AF). Catestatin is a multipurpose peptide that regulates cardiovascular systems and reduces harmful, excessive activity of the sympathetic nervous system by blocking the release of catecholamines. We aimed to determine whether serum catestatin concentrations are associated with AF severity, duration indices, and various clinical and laboratory indicators in these individuals to better define the clinical value of catestatin in patients with AF. The present single center study enrolled 73 participants with AF and 72 healthy age-matched controls. Serum catestatin concentrations were markedly higher in AF patients than controls (14.11 (10.21–26.02) ng/mL vs. 10.93 (5.70–20.01) ng/mL, p = 0.013). Furthermore, patients with a more severe form of AF had significantly higher serum catestatin (17.56 (12.80–40.35) vs. 10.98 (8.38–20.91) ng/mL, p = 0.001). Patients with higher CHA2DS2-VASc scores (17.58 (11.89–37.87) vs. 13.02 (8.47–22.75) ng/mL, p = 0.034) and higher NT-proBNP levels (17.58 (IQR 13.91–34.62) vs. 13.23 (IQR 9.04–22.61), p = 0.036) had significantly higher serum catestatin concentrations. Finally, AF duration correlated negatively with serum catestatin levels (r = −0.348, p = 0.003). The results of the present study implicate the promising role of catestatin in the intricate pathophysiology of AF, which should be explored in future research.