Growing interest in optical instruments for biomedical applications has increased the use of optically calibrated phantoms. Often associated with tissue modeling, phantoms allow the characterization of optical devices for clinical purposes. Fluorescent gel phantoms have been developed, mimicking optical properties of healthy and tumorous brain tissues. Specific geometries of dedicated molds offer multiple-layer phantoms with variable thicknesses and monolayer phantoms with cylindrical inclusions at various depths and diameters. Organic chromophores are added to allow fluorescence spectroscopy. These phantoms are designed to be used with 405 nm as the excitation wavelength. This wavelength is then adapted to excite large endogenous molecules. The benefits of these phantoms in understanding fluorescence tissue analysis are then demonstrated. In particular, detectability aspects as a function of geometrical and optical parameters are presented and discussed.
The aim of this study was to compare the effectiveness of a hand-held preoperative compact imager (POCI) camera with conventional lymphoscintigraphy using a γ-camera for sentinel lymph node (SLN) detection in breast cancer. Methods: The main objective was to demonstrate the noninferiority of the POCI relative to conventional lymphoscintigraphy and to compare the number of SLNs detected by the 2 imaging devices. Our study, a clinical prospective, double-blind, noninferiority study, planned to include 200 patients with early breast cancer and started in January 2006. A standard SLN protocol (4 periareolar injections of 37 MBq of 99mTc-nanocolloids, 2 h before lymphoscintigraphy) was performed preoperatively using a conventional γ-camera and then the POCI camera. Scans were obtained by 2 different nuclear medicine physicians unaware of each other's results. The day after, in the operating room, the surgeon, after receiving the previous results, used the counting probe for surgical SLN biopsy. The number and localization of axillary SLNs obtained by lymphoscintigraphy and the POCI and the duration of the whole procedure were determined. Results: Among the 162 patients included, 138 were evaluable. The POCI detected more SLNs than did lymphoscintigraphy in 50 patients (36%), the same number of in 54 patients (39%), and fewer SLNs in 34 patients (25%), representing 84 (61%) discordant pairs. The noninferiority of preoperative compact imaging of axillary SLNs numbers was found to be statistically significant (95% confidence interval, 30%–52%, P = 0.025) using the McNemar test. The duration of acquisition was shorter using the POCI (<10 min in 84% [n = 117] of patients; mean, 7.5 ± 3.3 min) than lymphoscintigraphy (13% [n = 18] of patients; mean, 15.7 ± 3.4 min), with P < 0.001 using the McNemar test for paired proportions. Conclusion: Preoperative compact imaging using a hand-held camera was able to predict the number and localization of breast cancer SLNs and was not inferior to conventional lymphoscintigraphy in this study. Further studies will determine whether preoperative compact imaging could replace lymphoscintigraphy, especially in surgical centers without an on-site nuclear medicine department.
The survival outcome of patients suffering from gliomas is directly linked to the complete surgical resection of the tumour. To help the surgeons to delineate precisely the boundaries of the tumour, we developed an intraoperative positron probe with background noise rejection capability. The probe was designed to be directly coupled to the excision tool such that detection and removal of the radiolabelled tumours could be simultaneous. The device consists of two exchangeable detection heads composed of clear and plastic scintillating fibres. Each head is coupled to an optic fibre bundle that exports the scintillating light to a photodetection and processing electronic module placed outside the operative wound. The background rejection method is based on a real-time subtraction technique. The measured probe sensitivity for (18)F was 1.1 cps kBq(-1) ml(-1) for the small head and 3.4 cps kBq(-1) ml(-1) for the large head. The mean spatial resolution was 1.6 mm FWHM on the detector surface. The gamma-ray rejection efficiency measured by realistic brain phantom modelling of the surgical cavity was 99.4%. This phantom also demonstrated the ability of the probe to detect tumour discs as small as 5 mm in diameter (20 mg) for tumour-to-background ratios higher than 3:1 and with an acquisition time around 4 s at each scanning step. These results indicate that our detector could be a useful complement to existing techniques for the accurate excision of brain tumour tissue and more generally to improve the efficiency of radio-guided cancer surgery.