Marc-Antoine Verdier

Marc-Antoine Verdier

Auto-generated profile, based on publicly available information

Marc-Antoine Verdier

Univ. Paris-Diderot, Sorbonne Paris Cité, IMNC CNRS-IN2P3, 91405 Orsay, France

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 December 2011 in Physical Review B
Verified
Journal Article
Closed access
MVM.-A. Verdier
M.-A. Verdier
PSP. C. F. Di Stefano
P. C. F. Di Stefano
PNP. Nadeau
P. Nadeau
CBC. Behan
C. Behan
MCM. Clavel
M. Clavel
CDChristophe Dujardin
Christophe Dujardin
Bismuth germanate (BGO) has been widely used as a room-temperature scintillator in many applications for decades. Interest in it has recently increased as a low-temperature scintillator to be used in bolometers for rare-event detection. We present our time-resolved-scintillation studies of BGO down to 3 K under $\gamma${}-ray excitation. Our multiple-photon-counting-coincidence-based setup allows clear identification of $\gamma${}-line energies at least as low as 122 keV down to base temperature and the measurement of the light yield and decay-time constants as a function of temperature. We also discuss the time structure of the pulses and report a previously unappreciated but significant, very slow component assigned to afterglow. Finally, we demonstrate that nonlinearity of the light yield as a function of energy persists at low temperatures.

1 December 2016 in Journal of Instrumentation
Verified
Journal Article
Closed access
PDF file
SSS. Spadola
S. Spadola
MVM.-A. Verdier
M.-A. Verdier
LPL. Pinot
L. Pinot
CEC. Esnault
C. Esnault
NDN. Dinu
N. Dinu
LML. Ménard
L. Ménard

14 November 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Open access
LAL. Ammour
L. Ammour
JHJ. Heymes
J. Heymes
MBM. Bautista
M. Bautista
SFS. Fieux
S. Fieux
FGF. Gensolen
F. Gensolen
MVM.-A. Verdier
M.-A. Verdier
Preclinical behavior neuroimaging gathers simultaneous assessment of behavior and functional brain imaging. It is a potential key breakthrough to improve the understanding of brain processes and assess the validity of preclinical studies in drug development. Achieving such a combination is difficult, anesthesia or restraints inherent to conventional nuclear imaging preclude its use for behavior studies. In that context, we have proposed an original strategy using submillimetric probes to directly measures positrons inside the rat brain. This paper gives the results of Monte Carlo simulations of a new generation of intracerebral positron probe based on a CMOS Monolithic Active Pixel Sensor. We present the results obtained for a probe into a large homogeneous volume of radioactive water (18F) leading to a sensitivity of 0.88 cps ∙ Bq-1 ∙ mm3 and a mean energy deposition by positrons of 15.1 keV. Simulation in simplified brain-shaped sources modeling a 11c-raclopride experiment shows that the implanted volume modeling the left putamen contribute to 92.4% of the signal from positrons. We also investigate the effects of the thickness of the sensitive layer, the energy threshold and pixel dimensions on the detection capacities of the sensor. We demonstrate that an increase in the sensitive thickness from 18 to 190μ would lead to an increase of positrons sensitivity by a factor of 1.74, but to a decrease of the direct (positrons) to indirect (γ-rays and electrons) sensitivity ratio by a factor of 1.59. Finally we show that for a threshold lower than about 5keV the effect of the pixel dimensions is negligible.

2 February 2022 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
CTCarlotta Trigila
Carlotta Trigila
MVMarc-Antoine Verdier
Marc-Antoine Verdier
LPLaurent Pinot
Laurent Pinot
FBFrançoise Bouvet
Françoise Bouvet
TBTiffany Beaumont
Tiffany Beaumont
LMLaurent Ménard
Laurent Ménard
Objective. Molecular radiotherapy is the most used treatment modality against malign and benign diseases of thyroid. In that context, the large heterogeneity of therapeutic doses in patients and the range of effects observed show that individualized dosimetry is essential for optimizing treatments according to the targeted clinical outcome. Approach. We developed a high-resolution mobile gamma camera specifically designed to improve the quantitative assessment of the distribution and biokinetics of 131 I at patients’s bedside after treatment of thyroid diseases. The first prototype has a field of view of 5 × 5 cm 2 and consists of a high-energy parallel-hole collimator made of 3D-printed tungsten, coupled to a 6 mm thick CeBr 3 scintillator readout by an array of silicon photomultiplier detectors. The intrinsic and overall imaging performance of the camera was evaluated with 133 Ba and 131 I sources. In order to test its quantification capability in realistic clinical conditions, two different 3D-printed thyroid phantoms homogeneously filled with 131 I were used. Both single view and conjugate view approaches have been applied, with and without scatter correction technique. Main Results. The camera exhibits high imaging performance with an overall energy resolution of 7.68 ± 0.01%, a submillimetric intrinsic spatial resolution of 0.74 ± 0.28 mm and a very low spatial distortion 0.15 ± 0.10 mm. The complete calibration of the camera shows an overall spatial resolution of 3.14 ± 0.03 mm at a distance of 5 cm and a corresponding sensitivity of 1.23 ± 0.01 cps/MBq, which decreases with distance and slightly changes with source size due to the influence of scattering. Activity recovery factors better than 97% were found with the thyroid phantoms. Significance. These preliminary results are very encouraging for the use of our camera as a tool for accurate quantification of absorbed doses and currently motivates the development of a fully operational clinical camera with a 10 × 10 cm 2 field of view and improved imaging capabilities.

14 December 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
TBT. Bossis
T. Bossis
MVM.-A. Verdier
M.-A. Verdier
LPL. Pinot
L. Pinot
FBF. Bouvet
F. Bouvet
TBT. Beaumont
T. Beaumont
LML. Ménard
L. Ménard

22 May 2024 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
SKS. El Ketara
S. El Ketara
FAF. Agnese
F. Agnese
LAL. Ammour
L. Ammour
SBS. Bouvard
S. Bouvard
OCO. Clausse
O. Clausse
MVM.-A. Verdier
M.-A. Verdier