Lorenzo Fini

Lorenzo Fini

Auto-generated profile, based on publicly available information

Lorenzo Fini

Department of Physics and Astronomy, University of Florence, via Giovanni Sansone 1, Fiorentino 50019 Sesto, Italy

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 1995 in Journal of Physics B: Atomic, Molecular and Optical Physics
Verified
Journal Article
Closed access
PDF file
SCStefano Cavalieri
Stefano Cavalieri
RER Eramo
R Eramo
LFL Fini
L Fini
We report an experimental study of a laser-induced resonance in the continuum of sodium, performed by measuring the modified atomic susceptibility. The sensitivity of the set-up has allowed the observation of the induced structure in conditions of relatively weak intensity of the dressing laser field, where the line shape is independent of the field amplitude and the comparison with theory is strict and direct. We have found a good agreement with theoretical predictions and measured the Fano parameter of the resonance.

6 October 2020 in Physical Review A
Verified
Journal Article
Closed access
PDF file
FTFederico Tommasi
Federico Tommasi
LFLorenzo Fini
Lorenzo Fini
FMFabrizio Martelli
Fabrizio Martelli
SCStefano Cavalieri
Stefano Cavalieri
The mean path-length invariance property is a very important property of scattering media illuminated by an isotropic and homogeneous radiation. Here, we investigate the case of inhomogeneous media with refractive-index mismatch between the external environment and also among their subdomains. The invariance property remains valid by the introduction of a correction, dependent on the refractive index, of the mean path-length value. It is a consequence of the stationary solution of the radiative transfer equation in a medium subjected to an isotropic and homogeneous radiance. The theoretical results are in agreement with the reported results for numerical simulations for both the three-dimensional and the two-dimensional media.

20 April 2022 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
ASAngelo Sassaroli
Angelo Sassaroli
FTFederico Tommasi
Federico Tommasi
SCStefano Cavalieri
Stefano Cavalieri
LFLorenzo Fini
Lorenzo Fini
ALAndre Liemert
Andre Liemert
FMFabrizio Martelli
Fabrizio Martelli
Significance: Code verification is an unavoidable step prior to using a Monte Carlo (MC) code. Indeed, in biomedical optics, a widespread verification procedure for MC codes is still missing. Analytical benchmarks that can be easily used for the verification of different MC routines offer an important resource. Aim: We aim to provide a two-step verification procedure for MC codes enabling the two main tasks of an MC simulator: (1) the generation of photons’ trajectories and (2) the intersections of trajectories with boundaries separating the regions with different optical properties. The proposed method is purely based on elementary analytical benchmarks, therefore, the correctness of an MC code can be assessed with a one-sample t-test. Approach: The two-step verification is based on the following two analytical benchmarks: (1) the exact analytical formulas for the statistical moments of the spatial coordinates where the scattering events occur in an infinite medium and (2) the exact invariant solutions of the radiative transfer equation for radiance, fluence rate, and mean path length in media subjected to a Lambertian illumination. Results: We carried out a wide set of comparisons between MC results and the two analytical benchmarks for a wide range of optical properties (from non-scattering to highly scattering media, with different types of scattering functions) in an infinite non-absorbing medium (step 1) and in a non-absorbing slab (step 2). The deviations between MC results and exact analytical values are usually within two standard errors (i.e., t-tests not rejected at a 5% level of significance). The comparisons show that the accuracy of the verification increases with the number of simulated trajectories so that, in principle, an arbitrary accuracy can be obtained. Conclusions: Given the simplicity of the verification method proposed, we envision that it can be widely used in the field of biomedical optics.

13 July 2024 in Advanced Theory and Simulations
Verified
Journal Article
Open access
FTFederico Tommasi
Federico Tommasi
LPLORENZO PATTELLI
LORENZO PATTELLI
SCStefano Cavalieri
Stefano Cavalieri
LFLorenzo Fini
Lorenzo Fini
MPmichela paolucci
michela paolucci
FMFabrizio Martelli
Fabrizio Martelli
Monte Carlo (MC) simulations are the gold standard for describing various transport phenomena and have largely contributed to the understanding of these processes. However, while their implementation for classical transport governed by exponential step‐length distributions is well‐established, widely accepted approaches are still lacking for the more general class of anomalous transport phenomena. In this work, a set of rules for performing MC simulations in anomalous diffusion media is identified, which is also applicable in the case of finite‐size geometries and/or heterogeneous inclusions. The results are presented in the context of radiative transfer, however their implications extend to all types of anomalous transport. The proposed set of rules exhibits full compatibility with the pathlength invariance property for random trajectories, and with the important radiometric concept of fluence. Additionally, it reveals the counter‐intuitive possibility of introducing interfaces between independent subdomains with identical properties, which arise from the fact that non‐exponential step‐length distributions have a “memory” that can in principle be reset when traversing a boundary. These results have far‐reaching consequences not just for the physical interpretation of the corrections required to handle these discontinuities, but also for their experimental verification, due to their expected effects on the observable pathlength distributions.

31 March 2025 in Journal of Optometry
Verified
Journal Article
Open access
FTFederico Tommasi
Federico Tommasi
AGAlessio Giorgetti
Alessio Giorgetti
CMCaterina Monnetti
Caterina Monnetti
LFLorenzo Fini
Lorenzo Fini
Giovanni RomualdiGiovanni Romualdi
Giovanni Romualdi
SCStefano Cavalieri
Stefano Cavalieri
This study presents a detailed optical characterization of three intraocular lenses (IOLs) comparing two so called "enhanced range of field", Evolux IOL and Tecnis Eyhance IOL and one so called "narrow range of field", a standard monofocal IOL Acrysof IQ. The measurements are performed using the PMTF optical bench, basing on the Modulation Transfer Function (MTF) to evaluate the optical performance of each lens. The MTFa, representing the area under the MTF curve, is utilized as a key and synthetic metric to quantify performance across different spatial frequencies, providing insights into the IOLs' behavior as defocus varies. The results highlight the strengths and the weaknesses of the IOLs, with the Evolux showing a broadest depth of focus. The USAF resolution target is used to qualitatively assess the image reproduction at far, intermediate, and near distances, offering a visual representation of the IOLs' capabilities. These findings provide valuable information for selecting IOLs based on patient-specific visual requirements in cataract and refractive surgery.

11 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
FTFederico Tommasi
Federico Tommasi
BABaptiste Auvity
Baptiste Auvity
LFLorenzo Fini
Lorenzo Fini
FMFabrizio Martelli
Fabrizio Martelli
SCStefano Cavalieri
Stefano Cavalieri
The research in optical sensors has been largely encouraged by the demand for low-cost and less or non-invasive new detection strategies. The invention of the random laser has opened a new frontier in optics, providing also the opportunity to explore new possibilities in the field of sensing, besides several different and peculiar phenomena. The main advantage in exploiting the physical principle of the random laser in optical sensors is due to the presence of the stimulated emission mechanism, which allows amplification and spectral modification of the signal. Here, we present a step forward in the exploitation of this optical phenomenon by a revisitation of a previous experimental setup, as well as the measurement method, in particular to mitigate the instability of the results due to shot-to-shot pump energy fluctuations. In particular, the main novelties of the setup are the use of optical fibers, a reference sensor, and a peristaltic pump. These improvements are devoted to: eliminating optical beam alignment issues; improving portability; mitigating the variation in pump energy and gain medium performances over time; realizing an easy and rapid change of the sensed medium. The results showed that such a setup can be considered a prototype for a portable device for directly measuring the scattering of liquid samples, without resorting to complicated numerical or analytic inversion procedures of the measured data, once the suitable calibration of the system is performed.