Kazuhiro Yoshida

Kazuhiro Yoshida

Auto-generated profile, based on publicly available information

Kazuhiro Yoshida

Department of Medical Engineering and Technology, Kitasato University School of Allied Health Sciences, Kanagawa, Japan

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2000 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
MMMichitaka Maruyama
Michitaka Maruyama
KYKazuhiro Yoshida
Kazuhiro Yoshida
TFToshiki Furutani
Toshiki Furutani
YIYukitoshi Inagaki
Yukitoshi Inagaki
MHMasahiro Horibe
Masahiro Horibe
HHHisao Hayakawa
Hisao Hayakawa
We have demonstrated interface-treated Josephson junctions without deposited barriers in a trilayer structure. In the junctions, barriers were formed through an etching process and an annealing process for base YBa2Cu3O7-x (YBCO) films. The junctions showed resistively-shunted-junction-type characteristics over the entire temperature range below 70 K. A magnetic field modulation of more than 80% was observed throughout the operating temperature range. The obtained I c R n product was 2.1 mV at 4.2 K. The 1σ spreads in the junction parameters of 10% or better were observed for eight out of nine junctions in a chip.

20 December 2018 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
SIShinsuke Ikeda
Shinsuke Ikeda
KUKatsufumi Uchiyama
Katsufumi Uchiyama
YMYojiro Minegishi
Yojiro Minegishi
KOKeiko Ohno
Keiko Ohno
MNMasaki Nakamura
Masaki Nakamura
MTMasashi Takaso
Masashi Takaso
Previous studies comparing antibiotic-loaded calcium phosphate cement to polymethylmethacrylate cement reported that although the former has higher elution volumes over a longer period, it is mechanically weak when used alone. To counter this problem, a double-layered antibiotic-loaded cement spacer in which calcium phosphate cement is coated with polymethylmethacrylate cement was created. In this study, we compared the double-layered spacer to the polymethylmethacrylate cement spacer in terms of eluent antibiotic concentration, bioactivity against methicillin-resistant Staphylococcus aureus, and mechanical strength. Double-layered and polymethylmethacrylate cement spacers that were loaded with vancomycin (VCM) were prepared and immersed in phosphate buffer for 84 days. To facilitate VCM elution from calcium phosphate cores in double-layered spacers, we also drilled multiple holes into the calcium phosphate layer from the spacer surface. We found that VCM concentrations in double-layered spacer eluents were higher than those in polymethylmethacrylate cement spacer eluents. The double-layered spacer also had higher bioactivity than the polymethylmethacrylate cement spacer. Although the polymethylmethacrylate cement spacer eluent lost the ability to inhibit bacterial growth on day 56, the double-layered spacer eluent maintained this ability for the duration of our study. Finally, the double-layered spacer retained high mechanical strength throughout the study period. The beneficial biomechanical and drug-eluting properties of the double-layered spacer might qualify it to serve as a promising biomaterial that could be used for managing periprosthetic joint infections.

1 March 2021 in Journal of Orthopaedic Science
Verified
Journal Article
Closed access
RTRyo Tazawa
Ryo Tazawa
HMHiroaki Minehara
Hiroaki Minehara
TMTerumasa Matsuura
Terumasa Matsuura
TKTadashi Kawamura
Tadashi Kawamura
RSRina Sakai
Rina Sakai
MTMasashi Takaso
Masashi Takaso

29 February 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KYKazuhiro Yoshida
Kazuhiro Yoshida
KFKensuke Fukushima
Kensuke Fukushima
RSRina Sakai
Rina Sakai
KUKatsufumi Uchiyama
Katsufumi Uchiyama
NTNaonobu Takahira
Naonobu Takahira
MUMasanobu Ujihira
Masanobu Ujihira
Uncemented acetabular shell primary stability is essential for optimal clinical outcomes. Push-out testing, rotation testing, and lever-out testing are major evaluation methods of primary stability between the shell and bone. However, these test methods do not consider shell loads during daily activity and shell installation angle. This study proposes a novel evaluation method of acetabular shell primary stability considering load during level walking and acetabular installation angles such as inclination and anteversion. To achieve this, a novel primary stability test apparatus was designed with a shell position of 40° acetabular inclination and 20° anteversion. The vertical load, corresponding to walking load, was set to 3 kN according to ISO 14242–1, which is the wear test standard for artificial hip joints. The vertical load was applied by an air cylinder controlled by a pressure-type electro-pneumatic proportional valve, with the vertical load value monitored by a load cell. Torque was measured when angular displacement was applied in the direction of extension during the application of vertical load. For comparison, we also measured torque using the traditional lever-out test. The novel primary stability test yielded significantly higher primary stabilities; 5.4 times greater than the lever-out test results. The novel primary stability test failure mode was more similar to the clinical failure than the traditional lever-out test. It is suggested that this novel primary stability test method, applying physiological walking loads and extension motions to the acetabular shell, better reflects in vivo primary stability than the traditional lever-out test.

10 May 2024 in CVIR Endovascular
Verified
Journal Article
Open access
PDF file
RKRyoichi Kitamura
Ryoichi Kitamura
KYKazuhiro Yoshida
Kazuhiro Yoshida
TMTakaaki Maruhashi
Takaaki Maruhashi
STSatoshi Tamura
Satoshi Tamura
YKYutaro Kurihara
Yutaro Kurihara
YAYasushi Asari
Yasushi Asari
Background: We aimed to compare the hydrodynamic values of carbon dioxide (CO2) and iodine contrast media for bleeding detection using an in vitro model. Materials and methods: We created a bleeding model with large and small wounds in simulated blood vessels. We connected a syringe to the bleeding model and the blood pressure transducer, filling the circuit with CO2 and iodine contrast media. The syringe’s piston was pressed, and the flow rate and intravascular pressure of the CO2 and iodine contrast media leaking from the bleeding model were measured. We compared each leaked contrast medium’s volume, sphere-equivalent diameter, and sphere-equivalent area. These values were analyzed to compare the visibility of the leakage objectively. Results: At a constant flow rate, the intravascular pressure required for the model to leak was lower for the CO2 than that for the iodine contrast medium. The CO2 contrast medium leakage volume, equivalent circle diameter, and equivalent circle area were greater than those of the iodine one. These values indicate higher CO2 visibility during fluoroscopy. Conclusions: In the bleeding model, a CO2 contrast medium may be more prone to leakage than the iodine one in large and small wounds. Regarding visibility, a CO2 contrast medium may be more likely to detect leakage than an iodine one.

30 September 2020 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
KYKazuhiro Yoshida
Kazuhiro Yoshida
KFKensuke Fukushima
Kensuke Fukushima
RSRina Sakai
Rina Sakai
KUKatsufumi Uchiyama
Katsufumi Uchiyama
NTNaonobu Takahira
Naonobu Takahira
MUMasanobu Ujihira
Masanobu Ujihira
Excellent primary stability of uncemented acetabular shells is essential to obtain successful clinical outcomes. However, in the case of developmental dysplasia of the hip (DDH), aseptic loosening may be induced by instability due to a decrease of the contact area between the acetabular shell and host bone. The aim of this study was to assess the primary stability of two commercially-available acetabular shells, hemispherical and hemielliptical, in normal and DDH models. Synthetic bone was reamed using appropriate surgical reamers for each reaming condition (normal acetabular model). The normal acetabular model was also cut diagonally at 40° to create a dysplasia model. Stability of the acetabular components was evaluated by the lever-out test. In the normal acetabular model conditions, the maximum primary stabilities of hemispherical and hemielliptical shells were observed in the 1-mm under- and 1-mm over-reamed conditions, respectively, and the resulting stabilities were comparable. The lateral defect in the dysplasia model had an adverse effect on the primary stabilities of the two designs. The lever-out moment of the hemielliptical acetabular shell was 1.4 times greater than that of the hemispherical acetabular shell in the dysplasia model. The hemispherical shell is useful for the normal acetabular condition, and the hemielliptical shell for the severe dysplasia condition, in the context of primary stability.