1 March 2000 in Japanese Journal of Applied Physics
We have demonstrated interface-treated Josephson junctions without deposited barriers in a trilayer structure. In the junctions, barriers were formed through an etching process and an annealing process for base YBa2Cu3O7-x
(YBCO) films. The junctions showed resistively-shunted-junction-type characteristics over the entire temperature range below 70 K. A magnetic field modulation of more than 80% was observed throughout the operating temperature range. The obtained I c R n product was 2.1 mV at 4.2 K. The 1σ spreads in the junction parameters of 10% or better were observed for eight out of nine junctions in a chip.
22 July 2015 in IEEE Transactions on Instrumentation and Measurement
We have evaluated the uncertainty in the differential sampling measurement of the RMS amplitude of 10 V waveform synthesis based on an AC programmable Josephson voltage standard system with a compact cooler and a modified digital voltmeter (DVM). The error due to a sampling DVM timer is much reduced with an external 20-MHz frequency reference for the sampling DVM. The thermal electromotive force voltage of our reverse-polarity relay switch is sufficiently small and stable for the application of a differential sampling system. We have also performed a variety of measurements to evaluate this differential sampling technique. The evaluation results show that the overall expanded uncertainty is 1.3 parts in 106 (k = 2) for the frequency of 62.5 Hz at an rms amplitude of 10 V.
19 October 2009 in Superconductor Science and Technology
7 March 2013 in IEEE Transactions on Instrumentation and Measurement
We have measured the low-frequency characteristics of thermal voltage converters down to 1 Hz using a differential sampling measurement system based on ac-programmable Josephson voltage standard (AC-PJVS) system. The measured ac–dc transfer difference of a planar multijunction thermal converter using our system is evaluated to be $< 1\ \mu\hbox{V/V}$ above 10 Hz and $< 35 \mu\hbox{V/V}$ at 1 Hz with lower uncertainties compared to the conventional method. The estimated overall uncertainty measured by using our system is 3.1 $\mu\hbox{V/V}$ $(k = 1)$ at the frequency of 10 Hz and root-mean-square voltage of 3 V. Our measurement results above 10 Hz are in good agreement with the results obtained by the conventional method within a standard deviation of the mean. Our differential sampling measurement system using AC-PJVS is a useful tool for low-frequency ac voltage metrology.
1 October 2005 in Physica C: Superconductivity and its Applications
20 December 2010 in IEEE Transactions on Applied Superconductivity
We have designed a fully integrated 5-bit flash-type single-flux quantum (SFQ) analog-to-digital converter (ADC), in which an error correction and a bit-interleaving circuit are integrated with complementary quasi-one-junction SQUID (CQOS) comparators, and we verified its operation in experiments. Two types of look-back error correction circuits with different clock schemes were designed for the integrated ADCs to avoid the gray zone in comparators and to convert gray code to binary code. The interleaving circuit was also used in the ADC to add one extra bit. A binary 5-bit A/D converter was integrated into an IC chip. Then, input waveforms at low frequencies were successfully retrieved from the binary data of the A/D converter without any errors. We also confirmed that the A/D converter operated properly by conducting tests in our cryocooling system using a 4K-GM cryocooler after the chip was flip-chip bonded onto a multi-chip-module (MCM) carrier. We also used the beat frequency method to test and confirm that the CQOS comparator operated effectively at high frequency, i.e., 3 bits at 15 GHz in the binary code operation and 4 bits at 15 GHz in the gray code operation. Furthermore, operations at sampling frequencies of up to 32 and 50 GHz with a low-frequency analog input signal were experimentally confirmed for a 4-bit comparator circuit with a critical current density Jc of 2.5 kA/cm2 and 10 kA/cm2 , respectively.