Marwa Wahsh

Marwa Wahsh

Auto-generated profile, based on publicly available information

Marwa Wahsh

Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

30 September 2023 in Dental and Medical Problems
Verified
Journal Article
Open access
MEManar El-Mahdy
Manar El-Mahdy
AAAhmad Aboelfadl
Ahmad Aboelfadl
FAFatma Ahmed
Fatma Ahmed
AEAhmed Elbanna
Ahmed Elbanna
MWMarwa Wahsh
Marwa Wahsh
Polyetherketoneketone (PEKK) was recently introduced as an alternative to titanium and ceramic implant abutments due to its apparent ability to dissipate excessive strain around dental implants. However, the biomechanical behaviors of implant abutment crown systems may change depending on the crown and abutment material combinations used. This study aimed to assess how the crown material affects strain generation and fracture resistance of PEKK hybrid abutment crowns. Sixteen dummy implants (Ø 3.7 x 11 mm), simulating maxillary first premolars, were restored with 16 milled PEKK hybrid abutments and randomly categorized into two groups according to the crown material (n = 8): Group C, milled composite crowns cemented on PEKK hybrid abutments; and Group Z, ultra-translucent zirconia crowns cemented on PEKK hybrid abutments. Before thermocycling, a cyanoacrylate-base adhesive was used to position two strain gauges on buccal and lingual crestal bone surfaces, and a vertical load (100 N) was applied to the central fossa to record the strain generated. Then, all samples were thermocycled between 5°C and 55°C before being loaded to fracture on a universal testing machine. Modes of failure were observed under an optical microscope, and representative samples were examined using a scanning electron microscope. Independent t-tests were used for intergroup comparisons. The significance level was set at (p < 0.05) for all tests.. The results showed a significant difference between both groups. The zirconia group recorded significantly higher strain and fracture resistance values than the composite group (p < 0.001). There was a positive correlation between the strain developed in peri-implant crestal bone and fracture resistance of the abutment crown complex. Strains developed in both groups were within the acceptable clinical range. The crown material substantially impacted the strain and fracture of the PEKK hybrid abutment crown system.

1 July 2021 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
ABAly Abdelkawy Badr
Aly Abdelkawy Badr
AAAmira Ahmed Abozaid
Amira Ahmed Abozaid
MWMarwa Mohamed Wahsh
Marwa Mohamed Wahsh
TSTarek Salah
Tarek Salah
Objective: The aim of the study was to evaluate the effect of extension of endocrown in pulp space and the effect of ferrule on the fracture resistance of anterior endocrowns made of nano-ceramic resin blocks. Material and Methods: Twenty-eight freshly extracted human upper central incisor teeth were prepared to receive CAD/CAM nanoceramic resin endocrowns with four different designs. The specimens were divided into two groups (n = 14) according to the extension of the endocrown inside root canal (A:short and B:long), then each group was further subdivided into another two subgroups (n = 7) according to the presence or absence of ferrule effect (1:ferrule and 2: no ferrule). Endocrowns were then fabricated using CEREC in lab and nanoceramic resin blocks (DENTSPLY Sirona, Germany) and LAVA ultimate (3M ESPE, Germany) blocks size 14L. Results: Two-way ANOVA showed that the ferrule (P > 0.0001) had statistically significant effect on the fracture resistance. However, the extension of the endocrown into the canal had no statistical significant effect on the fracture resistance (P = 0.837). The interactions between the independent variables (extension into the canal and ferrule) had statistically significant effect on the fracture resistance(P = 0.029). Load to fracture for group 1A was 439.53 N, 1B was 306.46 N, 2A was 516.29 N and 2B was 242.04 N. Conclusions: Fracture resistance was not improved by the long or short extensions of the endocrowns in the pulp space, however, the ferrule effect shows significant improvement of the fracture resistance of the nanoceramic resin endocrowns. Keywords Anterior endocrowns; Endocrown extensions; Fracture resistance; Nanoceramic resin blocks.

31 January 2020 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
SASalma Alghalayini
Salma Alghalayini
KEKamal Ebeid
Kamal Ebeid
AAAyman Aldahrab
Ayman Aldahrab
MWMarwa Wahsh
Marwa Wahsh
Objective: To evaluate ability of Nano Ceramic Composite endocrown to withstand occlusal forces when used in the anterior region. Material and Methods: Eighty endodontically treated maxillary central incisors teeth were randomly divided into two main groups according to the restoration type. 40 of these teeth were post, core and crown restorations and 40 were endocrown restorations. Then they were divided by halves into two subgroups according to the material used 20 were made with Lava Ultimate and the other 20 with IPS e.max. Each subgroup was then further subdivided into two divisions according to the remaining tooth structure above the CEJ (n=10): 2 mm and 0.5 mm above the CEJ. After teeth preparation, the restorations were all made by CAD/CAM system (Cerec MCXL). All samples had undergone cyclic fatigue testing, and then loaded to fracture using a universal testing machine. The specimens were measured and statistically analyzed using Mann-Whitney test for comparing the mean changes between the groups. Results: Lava Ultimate showed higher mean fracture load values than IPS e.max specimens. Conclusion: Endocrowns were found to be more favorable when used on endodontically treated teeth than the conventional post, core and crown restorations.KEYWORDSEndocrowns; All-ceramic; Fracture; Cyclic loading.

1 January 2023 in Egyptian Dental Journal
Verified
Journal Article
Open access
PDF file
HSHoda Abdel Sadek
Hoda Abdel Sadek
MWMarwa Wahsh
Marwa Wahsh
MSMohamed Saeed
Mohamed Saeed
Objectives: To investigate and compare the color stability and surface roughness of provisional restorative materials fabricated by 3D printing, milling and conventional techniques after immersion in different storage media. Materials and methods: The 84-disc specimens were fabricated and divided into 3 groups according to the technique of fabrication (n=28), group C: Conventional techniques, group M: milled technique, group P: 3d printed technique. Each group was divided into 4 subgroups according to storage media (n=7), Subgroup D: distilled water, subgroup C: coffee solution, subgroup Co: cola, and subgroup O: orange juice. Baseline color was measured using spectrophotometer then measured after 2 and 4 weeks of immersion in different storage media. Color change (ΔE) was assessed using of the CIE L*a*b* system. Surface roughness was also measured using profilometer for all specimens before and after immersion in staining solutions. The data was then collected and statistically analyzed using two-way ANOVA. The significance level was set at p < 0.05 within all tests. Results: Two-way ANOVA showed that the fabrication technique and interaction between variables had a significant effect on surface roughness. There was a significant interaction between fabrication method, solution type and storage time on color stability. Conclusions: The surface roughness of 3D printed materials was higher than milled and conventional groups. 3D printed and CAD-CAM milled materials had better color stability compared to conventional group.

30 September 2020 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
ARAshraf Refaie
Ashraf Refaie
MZMaged Zohdy
Maged Zohdy
AAAhmad Aboelfadl
Ahmad Aboelfadl
MWMarwa Wahsh
Marwa Wahsh
Objective:This clinical study was conducted to evaluate the effect of immediate loading on peri-implant soft tissue health using three protocols: i) Immediate functional loading using polymer infiltrated ceramic (PIC) material (IFLV). ii)Immediate functional loading using polymethyl methacrylate (PMMA) followed by delayed functional loading using PIC material (IFLP). iii) Immediate non-functional loading using PMMA followed by delayed functional loading using PIC material (INFLP). Material & Methods: 30 Implants were placed in the upper premolar area and divided randomly according to the immediate loading protocol. In the control group (INFLP), CAD/CAM PMMA crowns were placed out of occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns in functional occlusion. For (IFLV) group, CAD/CAM VITA ENAMIC crowns were immediately loaded in functional occlusion; while in (IFLP) group, CAD/CAM PMMA crowns were placed in functional occlusion for 3 months, and then replaced by CAD/CAM VITA ENAMIC crowns. Modified pink esthetic score (MPES) and probing depth were used for evaluation of peri-implant soft tissue at base line and follow up periods. Results: INFLP showed higher MPES results compared to IFLV and IFLP. Moreover, the INFLP probing depth at 3 months showed higher results compared to the other groups. Conclusions: Immediate non-functional loading showed the best outcomes. However, peri-implant soft tissue health of the immediate functional loading using the PIC crown material was clinically acceptable. Key Words Polymer infiltrated ceramics, immediate dental implant loading, peri-implant soft tissue health.