Sadiq J. Hamandi

Sadiq J. Hamandi

Auto-generated profile, based on publicly available information

Sadiq J. Hamandi

Bio-Medical Engineering, University of Al-Nahrain, Baghdad, Iraq

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 August 2023 in Cogent Engineering
Verified
Journal Article
Open access
BABasma A. Al-Ghali
Basma A. Al-Ghali
SHSadiq J. Hamandi
Sadiq J. Hamandi
HFHamza A. Fadhil
Hamza A. Fadhil
BRBadr Rashwani
Badr Rashwani

1 August 2024 in AL-Kindy College Medical Journal
Verified
Journal Article
Open access
PDF file
ZWZainab A. Wajeeh
Zainab A. Wajeeh
SHSadiq J. Hamandi
Sadiq J. Hamandi
WAWisam S. Al-Obaidi
Wisam S. Al-Obaidi
UKUmit Kervan
Umit Kervan
Background: In modern healthcare, decision-making processes are becoming increasingly data-driven, aiming to optimize patient care and resource allocation. Coronary artery bypass grafting (CABG) is a critical procedure for high-risk patients, and the use of intra-aortic balloon pump (IABP) assistance can significantly impact patient outcomes. Objective: To identify preoperative factors that predict the need for IABP assistance in high-risk CABG patients and to develop a predictive model that can enhance clinical decision-making. Subjects and Methods: The study involved fifty high-risk coronary artery bypass graft patients, with 24 cases necessitating intra-aortic balloon pump assistance and the rest not requiring it. Seven preoperative variables, including age, weight, ejection fraction, number of grafts, creatinine level, diabetic status, and blood pressure, were considered as potential predictors. SPSS was adopted to conduct a multi-variable regression analysis and derive the mathematical equations for the predictive model. A graphical user interface (GUI) was developed to utilize these equations for predicting the need for IABP support. Results: The findings revealed a strong correlation among several preoperative factors and the likelihood of requiring IABP assistance. By employing the predictions from the model to guide preoperative intra-aortic balloon insertion, the potential for optimizing hemodynamic support during surgery was maximized. Conclusions: This research emphasizes the importance of enhancing risk assessment techniques to empower medical specialists to tailor treatment plans to each patient's specific needs. Early identification of individuals at risk of requiring IABP can significantly enhance surgical outcomes and patient safety. Incorporating the predictive model into clinical practice allows for more individualized and effective care during high-risk CABG surgeries. This modern strategy has the potential to revolutionize cardiac outcomes, improve patient results, and extend the use of intra-aortic balloon support.

1 January 2023
Verified
Conference Paper
Open access
BRBalsam M. Rashid
Balsam M. Rashid
SHSadiq J. Hamandi
Sadiq J. Hamandi
EKEman G. Khalil
Eman G. Khalil

9 August 2021 in Advances in Orthopedics
Verified
Journal Article
Open access
PDF file
UKUmaima Khairy
Umaima Khairy
SHSadiq J. Hamandi
Sadiq J. Hamandi
AAAhmed S. Abid Ali
Ahmed S. Abid Ali
The alignment of tibial component in total knee replacement operation must be achieved in three planes to ensure optimum results. In coronal plane, the alignment depends on three anatomical landmarks. These landmarks are tibial tuberosity, leg shin, and midtalar point. In eastern community, people get used to sit cross-legged which causes additional tension in the quadriceps muscle which is attached distally to the tibial tuberosity. This tension causes adaptation of the tuberosity laterally. Tuberosity adaptation causes the three anatomical landmarks being not collinear. In this work, eight cases of lateral adapted tubercle were diagnosed of this condition before the surgery and their X-ray images after the surgery were checked regarding tibial alignment. Tibial alignment has been checked by measuring the medial proximal tibial angle (MPTA) which is the angle between the mechanical tibial axis and the tibial component plateau. MPTAs for the eight cases were (86.9 degrees-93.6 degrees). Three cases had MPTA less than 90 degrees indicating varus alignment and five of them had MPTA more than 90 degrees indicating valgus alignment. A geometrical tool was designed using the DesignSpark Mechanical software as a proposed solution to solve the adaptation problem. The tool can give a method for fixing the tibial component precisely without any varus\valgus malalignment.

12 April 2024 in International Journal of Online and Biomedical Engineering (iJOE)
Verified
Journal Article
Open access
PDF file
ANAlaa A. Najim
Alaa A. Najim
SHSadiq J. Hamandi
Sadiq J. Hamandi
AAAhmed Alzubaidi
Ahmed Alzubaidi
The Ilizarov fixator is a type of external fixator that is used to treat patients who have suffered injuries from accidents, bone shortening, or nonunion of the bone. The principle behind the Ilizarov fixator is that thin wires (called Kirschner wires) are used to support the bones and connect them to framed rings. Before being fastened to the rings, the wires are tensioned and drilled through the bones. This study suggests using a new parallel wires configuration at the same level on the same ring and two revised versions, which are divergent and convergent models, and compare them with standard wires, 60 angle wires model. All models were designed using SolidWorks, a computer-aided design (CAD) software, and then analyzed in four conditions (axial compression, medial bending, posterior bending, and torsion) with Finite Element Analysis (FEA) using Ansys Workbench 2020 R2. Mechanical testing was conducted to validate the FEA results, A simple model consisting of a single ring, two K-wires, and polylactic acid (PLA) cylinders was utilized in a tensile test. It has been concluded from the results that the parallel model and its improvement have higher stiffness to axial compression, medial bending, and torsion, but a lower posterior bending stiffness, except the divergent model with 8-hole separation which has a relatively acceptable stiffness for posterior bending.