There are several international regulations regarding trace elements. The use of ICP-MS for their determination is usually a difficult task, especially when Hg is one of the target elements.
1 February 2011 in Journal of Food Composition and Analysis
A simple method with a fast sample preparation procedure for total and inorganic mercury determinations in blood samples is proposed based on flow injection cold vapor inductively coupled plasma mass spectrometry (FI-CV ICP-MS). Aliquots of whole blood (500 µL) are diluted 1 + 1 v/v with 10.0% v/v tetramethylammonium hydroxide (TMAH) solution, incubated for 3 h at room temperature and then further diluted 1 + 4 v/v with 2.0% v/v HCl. The inorganic Hg was released by on-line addition of L-cysteine and then reduced to elemental Hg by SnCl2. On the other hand, total mercury was determined by on-line addition of KMnO4 and then reduced to elemental Hg by NaBH4. Samples were calibrated against matrix-matching. The method detection limit was found to be 0.80 µg L−1 and 0.08 µg L−1 for inorganic and total mercury, respectively. Sample throughput is 20 samples h−1. The method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). For additional validation purposes, human whole blood samples were analyzed by the proposed method and by an established CV AAS method, with no statistical difference between the two techniques at 95% confidence level on applying the t-test.
14 February 2005 in Journal of Analytical Atomic Spectrometry
A very simple procedure is proposed for the determination of total and inorganic Hg in biological materials. Organic Hg (methylmercury) can be obtained from the difference. After treating the sample at room temperature with tetramethylammonium hydroxide (TMAH), inorganic Hg is obtained by cold vapor atomic absorption spectrometry (CV-AAS), keeping the quartz cell at room temperature, while total Hg is obtained by the same technique, heating the quartz cell in an air–acetylene flame. By analyzing several biological certified materials, it was evident that the difference between the mentioned concentrations corresponds to methylmercury. Cold vapor graphite furnace atomic absorption spectrometry (CV-GF-AAS) with retention of the vapor in a heated Au-treated graphite tube was used to optimize the vapor generation conditions and also to determine total Hg. In a general way, the concentrations obtained by both techniques were in agreement with the certified values or with differences of the certified values for total, Hg2+ and CH3Hg+, according to the t-test for a 95% confidence level. Total Hg results obtained by the two techniques were also in agreement. The relative standard deviations were lower than 10% for most of the results. The detection limits in the sample were: 0.13 μg g−1 for total Hg and 0.025 μg g−1 for Hg2+ by CV-AAS. The detection limit for total Hg by CV-GF-AAS was 0.001 μg g−1. It is amazing how this very simple method is able to provide very important information on mercury speciation.