Vanessa Hernández-Montes

Vanessa Hernández-Montes

Auto-generated profile, based on publicly available information

Vanessa Hernández-Montes

Universidad Nacional de Colombia. Sede Medellín. Facultad de Minas. Medellín, Colombia, Grupo de Tribología y Superficies, Medellín, Colombia

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2023 in RSC Advances
Verified
Journal Article
Open access
PDF file
VHV. Hernández-Montes
V. Hernández-Montes
Robison BuitragoRobison Buitrago
Robison Buitrago
MEMónica Echeverry-Rendón
Mónica Echeverry-Rendón
JSJ. F. Santa-Marín
J. F. Santa-Marín
Current research trends in Mg alloys are focused on the development of smart coatings with self-healing properties that improve corrosion resistance of these alloys. Ceria based materials have recently emerged as materials that can be used as smart coatings on Mg alloys.

1 January 2017 in DYNA
Verified
Journal Article
Open access
VHVanessa Hernández-Montes
Vanessa Hernández-Montes
CBClaudia Patricia Betancur-Henao
Claudia Patricia Betancur-Henao
JSJuan Santa
Juan Santa
El magnesio y sus aleaciones, que aún se encuentran en desarrollo, se usan en aplicaciones ortopédicas debido a su biocompatibilidad y propiedades mecánicas (similares al hueso), que los hacen adecuados para aplicaciones en biomateriales. El magnesio tiene potencial para ser usado en implantes biodegradables dada su capacidad de soportar los procesos de regeneración de tejidos. En consecuencia, se han desarrollado varias estrategias para mejorar las propiedades del magnesio. Los recubrimientos sobre magnesio se emplean para mejorar su citocompatibilidad y resistencia a la corrosión. Específicamente, el dióxido de titanio se puede usar como recubrimiento protector sobre el magnesio, con el fin de ayudar a regular la velocidad de degradación y superar algunos problemas que se encuentran cuando el magnesio es implantado en el cuerpo. Por tanto, en este artículo se realizó una revisión crítica para consolidar la literatura disponible acerca de recubrimientos de dióxido de titanio sobre aleaciones de magnesio para potenciales aplicaciones en biomateriales. En este documento se hace énfasis en los recubrimientos obtenidos por medio de la de la ruta sol-gel como técnica prometedora para aplicaciones biomédicas.

30 July 2020 in Advances in Natural Sciences: Nanoscience and Nanotechnology
Verified
Journal Article
Closed access
CBC Betancur-Henao
C Betancur-Henao
VHV Hernández-Montes
V Hernández-Montes
JSJuan Santa
Juan Santa
Robison BuitragoRobison Buitrago
Robison Buitrago
Titanium dioxide (TiO 2 ) is an attractive biomaterial for its antibacterial properties. In this paper, TiO 2 nanoparticles were co-doped with copper and nitrogen and deposited onto polypropylene (PP) by the dip-coating technique. The nanoparticles were synthesised via the sol-gel technique and co-doped by the wet impregnation method. The physicochemical properties of the samples were characterised using scanning electron microscopy (SEM), wavelength-dispersive spectrometry (WDS), x-ray diffraction (XRD), x-ray photoelectron spectroscopy (XPS), and ultraviolet-visible (UV–vis) spectroscopy. The band gap energy was determined using a Tauc plot. The antibacterial activity was evaluated against gram-positive, gram-negative, and multi-resistant bacteria by measuring the number of colony-forming units (CFUs). All the tests were conducted in the presence of visible light. The results showed that the nanoparticles have a mean diameter of 20.40 ± 5.50 nm. The Cu–N-doped nanoparticles showed a 23% decrease of the band gap compared to their unmodified counterparts. The PP showed homogeneous coatings with a mean thickness of 33.00 ± 1.70 μ m. The PP modified with Cu-N-doped TiO 2 exhibited strong antibacterial activity against E. coli (81%), S. aureus (98%) and methicillin-resistant S. aureus (MRSA) (97%) compared to unmodified PP. The results demonstrated the antibacterial activity of TiO 2 –Cu–N nanoparticles against gram-negative and gram-positive bacteria and their potential use in biomedical applications.

16 December 2025 in Surfaces and Interfaces
Verified
Journal Article
Closed access
VHVanessa Hernández-Montes
Vanessa Hernández-Montes
JSJuan Santa
Juan Santa
Robison BuitragoRobison Buitrago
Robison Buitrago
JLJavier Llorca
Javier Llorca
MRMONICA ECHEVERRY RENDON
MONICA ECHEVERRY RENDON

2 July 2018 in INGE CUC
Verified
Journal Article
Open access
PDF file
JHJohan Esteban López Herrera
Johan Esteban López Herrera
VMVanessa Hernández Montes
Vanessa Hernández Montes
CHClaudia Patricia Betancur Henao
Claudia Patricia Betancur Henao
JSJuan Santa
Juan Santa
Robison BuitragoRobison Buitrago
Robison Buitrago
Introduction: Magnesium alloys have been known for its biocompatible characteristics and tissue restoration properties. On the other hand, TiO2 has been found to decrease the corrosion rates of the magnesium alloys. Objective: In this work, the dip-coating technique was used to coat the magnesium alloy with TiO2 particles in order to evaluate its corrosion resistance. Methodology: The particles were analyzed by Scanning Electron Microscopy (SEM) and visual inspection. Additionally, hydrogen evolution tests were performed to understand the effect of adding TiO2 in corrosion rates of Mg-alloys. Results: The results showed the positive effect of TiO2 in the improvement of the ASTM B107 AZ31B Mg alloys corrosion by an indirect measurement through hydrogen evolution tests. The bare ASTM B107 AZ31B showed a corrosion 29 times faster compared to the coated alloy. The thickness of the coatings obtained using the dip-coating method is thinner than 20 nm. Conclusions: TiO2 particles were aggregated on the surface of the ASTM B107 AZ31B alloy with a controlled speed. SEM images have shown the improvement of the coating when the H2O concentration in the sol increased. Another important parameter is the withdrawal speed during the dip-coat process which was found to be better at a speed of 3mm/min. Hydrogen evolution in the acid solution showed that coated ASTM B107 AZ31B has less hydrogen production during the corrosion test. The dip-coating technique can also be used to coat polypropylene discs entirely.