Given the emergence of the Internet of Things (IoT) Cyber-Physical Systems (CPSs) and their omnipresence, reducing their power consumption is among the major design priorities. To reduce the power consumption of such systems, we propose the use of a signal-dependent sampling method in a bottom-up fashion, which can lead to up to a 94% reduction in the overall system power with negligible or no loss in performance. Moreover, the proposed technique provides further flexibility for self-aware CPSs to dynamically adjust the number of data samples that are needed for processing (and consequently reduce the power consumption) based on the application at hand and the desired trade-off between accuracy and power consumption. To show the merits of the proposed approach, we also present case studies in the context of an Electrocardiography (ECG) monitoring system as well as a greenhouse (temperature and relative humidity) monitoring system. We also discuss the trade-offs among the system configuration parameters, power consumption, and performance (accuracy). We show that the proposed method has a negligible overhead, which facilitates the real-time operation of the IoT CPS while achieving significant power savings (up to 94%). Even though we study the effects of using this method for two representative applications, the technique is general and can offer similar improvements for a wide range of CPSs and resource-constrained IoT systems.
8 August 2024 in IEEE Journal of Solid-State Circuits
Real-time monitoring of dynamic biological processes in the body is critical to understanding disease progression and treatment response. These data, for instance, can help address the lower than 50% response rates to cancer immunotherapy. However, current clinical imaging modalities lack the molecular contrast, resolution, and chronic usability for rapid and accurate response assessments. Here, we present a fully wireless image sensor featuring a $2.5{\times }5$ mm2 CMOS integrated circuit for multicolor fluorescence imaging deep in tissue. The sensor operates wirelessly via ultrasound (US) at 5-cm depth in oil, harvesting energy with 221-mW/cm2 incident US power density (31% of FDA limits) and backscattering data at 13 kb/s with a bit error rate $\lt 10{^{-6}}$ . In situ fluorescence excitation is provided by micro-laser diodes controlled with a programmable on-chip driver. An optical front-end combining a multi-bandpass interference filter and a fiber optic plate (FOP) provides >6 OD excitation blocking and enables three-color imaging for detecting multiple cell types. A $36{\times }40$ pixel array captures images with <125-$\mu $ m resolution. We demonstrate wireless, dual-color fluorescence imaging of both effector and suppressor immune cells in ex vivo mouse tumor samples with and without immunotherapy. These results show promise for providing rapid insight into therapeutic response and resistance, guiding personalized medicine.
12 March 2024 in IEEE Transactions on Biomedical Circuits and Systems
We present a mm-sized, ultrasonically powered lensless CMOS image sensor as a progress towards wireless fluorescence microscopy. Access to biological information within the tissue has the potential to provide insights guiding diagnosis and treatment across numerous medical conditions including cancer therapy. This information, in conjunction with current clinical imaging techniques that have limitations in obtaining images continuously and lack wireless compatibility, can improve continual detection of multicell clusters deep within tissue. The proposed platform incorporates a 2.4×4.7 mm 2 integrated circuit (IC) fabricated in TSMC 0.18 μm, a micro laser diode (μLD), a single piezoceramic and off-chip storage capacitors. The IC consists of a 36×40 array of capacitive trans-impedance amplifier-based pixels, wireless power management and communication via ultrasound and a laser driver all controlled by a Finite State Machine. The piezoceramic harvests energy from the acoustic waves at a depth of 2 cm to power up the IC and transfer 11.5 kbits/frame via backscattering. During Charge-Up , the off-chip capacitor stores charge to later supply a high-power 78 mW μLD during Imaging . Proof of concept of the imaging front end is shown by imaging distributions of CD8 T-cells, an indicator of the immune response to cancer, ex vivo , in the lymph nodes of a functional immune system (BL6 mice) against colorectal cancer consistent with the results of a fluorescence microscope. The overall system performance is verified by detecting 140 μm features on a USAF resolution target with 32 ms exposure time and 389 ms ultrasound backscattering.
We present a mm-sized, ultrasonically powered lensless CMOS image sensor as a progress towards wireless fluorescence microscopy. Access to biological information within the tissue has the potential to provide insights guiding diagnosis and treatment across numerous medical conditions including cancer therapy. This information, in conjunction with current clinical imaging techniques that have limitations in obtaining images continuously and lack wireless compatibility, can improve continual detection of multicell clusters deep within tissue. The proposed platform incorporates a 2.4×4.7 mm 2 integrated circuit (IC) fabricated in TSMC 0.18 μm, a micro laser diode (μLD), a single piezoceramic and off-chip storage capacitors. The IC consists of a 36×40 array of capacitive trans-impedance amplifier-based pixels, wireless power management and communication via ultrasound and a laser driver all controlled by a Finite State Machine. The piezoceramic harvests energy from the acoustic waves at a depth of 2 cm to power up the IC and transfer 11.5 kbits/frame via backscattering. During Charge-Up , the off-chip capacitor stores charge to later supply a high-power 78 mW μLD during Imaging . Proof of concept of the imaging front end is shown by imaging distributions of CD8 T-cells, an indicator of the immune response to cancer, ex vivo , in the lymph nodes of a functional immune system (BL6 mice) against colorectal cancer consistent with the results of a fluorescence microscope. The overall system performance is verified by detecting 140 μm features on a USAF resolution target with 32 ms exposure time and 389 ms ultrasound backscattering.
In curative-intent cancer surgery, intraoperative fluorescence imaging of both diseased and healthy tissue can help to ensure successful removal of all gross and microscopic disease with minimal damage to neighboring critical structures, such as nerves. Current fluorescence-guided surgery (FGS) systems, however, rely on bulky and rigid optics that incur performance-limiting trade-offs between sensitivity and maneuverability. Moreover, many FGS systems are incapable of multiplexed imaging. As a result, clinical FGS is currently limited to millimeter-scale detection of a single fluorescent target. Here we present a scalable, lens-less fluorescence imaging chip, VISION, capable of sensitive and multiplexed detection within a compact form factor. Central to VISION is a novel optical frontend design combining a low-numerical-aperture fiber optic plate (LNA-FOP) and a multi-bandpass interference filter, which is affixed to a custom CMOS image sensor. The LNA-FOP acts as a planar collimator to improve resolution and compensate for the angle-sensitivity of the interference filter, enabling high-resolution and multiplexed fluorescence imaging without lenses. We show VISION is capable of detecting tumor foci of less than 100 cells at near video framerates and, as proof of principle, can simultaneously visualize both tumor and nerves in ex vivo prostate tissue.
1 January 2026 in IEEE Solid-State Circuits Magazine