Rudolf Guthoff

Rudolf Guthoff

Auto-generated profile, based on publicly available information

Rudolf Guthoff

Department of Ophthalmology, University of Rostock, Rostock, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Journal of Controlled Release
Verified
Journal Article
Closed access
KVKarsten Voss
Karsten Voss
KFKaren Falke
Karen Falke
ABArne Bernsdorf
Arne Bernsdorf
NGNiels Grabow
Niels Grabow
CKChristian Kastner
Christian Kastner
MHMarina Hovakimyan
Marina Hovakimyan

4 November 2016 in Eye
Verified
Journal Article
Open access
BKBhavani Kowtharapu
Bhavani Kowtharapu
KWKarsten Winter
Karsten Winter
CMC Marfurt
C Marfurt
SAStephan Allgeier
Stephan Allgeier
BKB Köhler
B Köhler
RGR F Guthoff
R F Guthoff
Eye is the official journal of the Royal College of Ophthalmologists. It aims to provide the practising ophthalmologist with information on the latest clinical and laboratory-based research.

17 December 2014 in Klinische Monatsblätter für Augenheilkunde
Verified
Journal Article
Closed access
PDF file
SZS. Zettl
S. Zettl
SRS. Reiß
S. Reiß
TTT. Terwee
T. Terwee
RGR. F. Guthoff
R. F. Guthoff
RBR. Beck
R. Beck
OSOliver Stachs
Oliver Stachs
Hintergrund: Immer mehr Patienten wünschen sich, im Rahmen einer beidseitigen Kataraktoperation Brillenunabhängigkeit zu erreichen. Prinzipiell existieren dazu die Optionen der pseudophaken Monovision, der Multifokallinsen und der sog. akkommodativen Linsen. Ziel der vorgestellten Studie ist die Erfassung der Alltagstauglichkeit einer geringen Monovision, also der Minimonovision. Material/Methoden: In dieser klinischen retrospektiven Studie wurden 30 beidseits pseudophake Patienten mit implantierten AcrySof®-IOL oder Acreos® Adapt-IOL mit einer geringen Anisometropie von 0,5–1,75 dpt und einem maximalen Astigmatismus bis 1,5 dpt untersucht. Fernvisus (ETDRS: Early Treatment Diabetic Retinopathy Study), Intermediär- (Jaeger 80 cm) und Nahvisus (Jaeger 40 cm) sowie Defokuskurven wurden erhoben. Weiterhin wurden Lesegeschwindigkeit und kritische Schriftgröße (Radner), Aniseikonie (FA Oculus nach Esser), Stereopsis (Titmus) und subjektive Patientenzufriedenheit (adaptierter VF-14-Fragebogen) sowie subjektive Brillenabhängigkeit bestimmt. Ergebnisse: Die Anisometropie lag im Median bei 0,75 dpt, das Alter zwischen 61 und 80 Jahren (Median 73 Jahre). 12 Patienten waren männlich und 18 weiblich. Es konnte binokular zu 100 % ein Fernvisus von mindestens dezimal 1,0 (LogMAR 0) und ein Intermediärvisus von mindestens dezimal 0,8 (LogMAR 0,1) sowie zu 86,57 % ein Nahvisus von mindestens Jaeger 5 (LogMAR 0,4), zu 63,33 % sogar von mindestens Jaeger 3 (LogMAR 0,3) nachgewiesen werden. Im Median lagen die binokulare unkorrigierte durchschnittliche Lesegeschwindigkeit photopisch bei 145 Wörtern/Minute und mesopisch bei 117 Wörtern/Minute, die kritische Schriftgröße photopisch bei LogRAD 0,60 (ca. Jaeger 5–6), die Aniseikonie bei 2 % und die Stereopsis bei 80 Bogensekunden. Die allgemeine Brillenabhängigkeit sank von präoperativ 100 % auf postoperativ 13 %, dies ging einher mit einer hohen Patientenzufriedenheit und einem VF-14-Fragebogen-Score von im Median 93,18 und ist vergleichbar den Literaturangaben zur vollen Monovision und zu Multifokallinsen. Schlussfolgerung: Die pseudophake Minimonovision ist bei geeigneter Patientenauswahl und unter Berücksichtigung einer relativen Einbuße beim Nahvisus eine erfolgreiche Möglichkeit zur Brillenunabhängigkeit im Alltag und stellt eine kostengünstige Alternative zu multifokalen IOL dar. Zur Festlegung der optimalen Zielrefraktion sind weitere Untersuchungen notwendig. Zu diesem Zwecke ist eine möglichst gezielte Berücksichtigung der Schärfentiefe hilfreich. Background: Modern day patients who undergo bilateral cataract surgery expect to be spectacles-independent after surgery. The options that are available to attain this goal are pseudophakic monovision, implanting multifocal IOLs or alternatively accommodative IOLs. The aim of this study is to establish the suitability in daily life when attaining minor monovision, named hereafter mini-monovision. Material/Methods: In this clinical retrospective study 30 patients were examined. These subjects where bilaterally pseudophake and received either AcrySof®-IOL or Acreos® Adapt-IOL with a slight anisometropia of between 0.5 and 1.75 D and with a maximal astigmatism up to 1.5 D. Visual acuity (VA) for distance (ETDRS), intermediate (Jaeger 80 cm) and near (Jaeger 40 cm) as well as defocus curves were assessed. Furthermore were examined: the reading speed using the font size of the Radner reading chart, anisoconia (FA Oculus according to Esser), stereopsis (Titmus), subjective patient satisfaction (adapted VF-14-questionnaire) and the subjective dependence on having to wear spectacles. Results: The median anisometropia was at 0.75 D; the age was between 61 and 80 (median being at 73 years). 12 patients were male and 18 female. When examined with binocular vision 100 % could attain distance VA of at least decimal 1.0 (LogMAR 0) and an intermediate VA of at least decimal 0.8 (LogMAR 0.1), up to 86.57 % a near VA of at least Jaeger 5, (LogMAR 0.4); up to 63.33 % even managed at least Jaeger 3 (LogMAR 0.3). The median average reading speed for binocular uncorrected reading under photopic conditions was 145 words/minute and under mesopic conditions 117 words/minute. The critical font size was LogRAD 0.60 (Jaeger 5–6), the anisoconia at 2 % and stereopsis at 80 arc seconds. The general dependence on glasses was reduced from 100 % preoperatively to 13 %, postoperatively. Simultaneously a high patient satisfaction score of 93.18 in the VF-14 questionnaire was attained. The result is comparable to those quoted in the literature on full monovision and mulitifocal IOLs. Conclusion: To attain spectacles independency, pseudophake mini-monovision is a cost efficient alternative to multifocal lenses for well selected patients. A relative reduction in near VA must be taken into account. To establish the refractive target further examinations are required. Establishing the accurate depth of vision will be helpful in attaining this. * S. Zettl und S. Reiß haben gleichberechtigte Autorenschaft.

17 December 2014 in Klinische Monatsblätter für Augenheilkunde
Verified
Journal Article
Closed access
PDF file
SRS. Reiß
S. Reiß
JFJ. Forbrig
J. Forbrig
RGR. F. Guthoff
R. F. Guthoff
TTT. Terwee
T. Terwee
HSH. Stolz
H. Stolz
OSOliver Stachs
Oliver Stachs
Die Anwendung der diffraktiven Eigenschaften von Fresnel-Zonenplatten bietet die Möglichkeit des Designs von Intraokularlinsen mit mehreren Fokussen. Derartige Intraokularlinsen können durch Anwendung der 2-Photonen-Polymerisation (2PP) hergestellt werden. Dieser Beitrag erläutert dieses Konzept und zeigt Prinzipien der Visualisierung von Fokuseigenschaften derartiger Implantate. The utilisation of the diffractive properties of Fresnel zone plates offers the possibility of intraocular lens designs with multiple foci. Such intraocular lenses can be manufactured by two-photon polymerisation (2PP). This paper explains the underlying concept and shows the principles for visualisation of the focus properties of such implants.

10 December 2013 in Klinische Monatsblätter für Augenheilkunde
Verified
Journal Article
Closed access
PDF file
TRT. Ramoth
T. Ramoth
MHM. Hovakimyan
M. Hovakimyan
RGR. F. Guthoff
R. F. Guthoff
OSOliver Stachs
Oliver Stachs
Die Implementierung von zusätzlichen Modulen zur Charakterisierung der Tränenfilmdynamik erhöht das Anwendungsspektrum des Oculus® Keratographen 5M. Das Ziel der vorgestellten Untersuchung war es einerseits, die Möglichkeiten der nicht invasiven Messung der Break-up Time mit dem Oculus Keratographen zu beurteilen. Andererseits sollten Möglichkeiten der Anwendung dieser Methode bei einer Tränenersatzmittelapplikation (Thealoz®, Théa Pharma) und der damit verursachten Beeinflussung des Tränenfilms untersucht werden. Unserer Ansicht nach sind weitere Untersuchungen zur Standardisierung der Methodik bei der Analyse der sogenannten ersten bzw. durchschnittlichen sogenannten Tränenaufreißzeit notwendig. Jedoch erscheinen die Möglichkeiten einer topografischen Analyse der Dynamik des Tränenfilmaufrisses sehr aussagekräftig und sollten in den Mittelpunkt gerückt werden. Die gefundenen Resultate bez. einer Tränenersatzmittelapplikation bei Trockenem Auge stützen die bereits in Zellkulturexperimenten gefundene These einer protektiven und tränenfilmstabilisierenden Wirkung von Thealoz®. The implementation of additional modalities for tear film break-up time characterisation expands the application range of the Oculus® Keratograph 5M. The aim of the present study was to evaluate the possibilities for non-invasive break-up time analysis using this device. Furthermore we applied the Oculus® Keratograph 5M to characterise possible modifications of tear break-up time after application of Thealoz® eye drops (Théa Pharma). The device allowed for a precise and solid topographical analysis of tear film dynamics. We could show that at four weeks after treatment, trehalose solution was a better treatment for dry eye compared with saline. These results are in agreement with our previous in vitro findings concerning the protective role of trehalose on desiccation-caused cell death in a corneal epithelial model.

19 August 2016 in Journal of Microscopy
Verified
Journal Article
Closed access
BKB.S. Kowtharapu
B.S. Kowtharapu
CMC. Marfurt
C. Marfurt
MHM. Hovakimyan
M. Hovakimyan
FWF. Will
F. Will
HRH. Richter
H. Richter
RGR.F. Guthoff
R.F. Guthoff