Christopher B C Dean

Christopher B C Dean

Auto-generated profile, based on publicly available information

Christopher B C Dean

Department of Statistics, University of Warwick, Department of Statistics, University of Warwick, Coventry, Coventry, CV4 7AL, United Kingdom of Great Britain and Northern Ireland

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Spatial and Spatio-temporal Epidemiology
Verified
Journal Article
Closed access
PMPaula Moraga
Paula Moraga
CDChristopher Dean
Christopher Dean
JIJoshua Inoue
Joshua Inoue
PMPiotr Morawiecki
Piotr Morawiecki
SNShahzeb Raja Noureen
Shahzeb Raja Noureen
FWFengpei Wang
Fengpei Wang

20 March 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CDChristopher B C Dean
Christopher B C Dean
MLMaria Laura Perez Lara
Maria Laura Perez Lara
EHEmma Horton
Emma Horton
MSMatthew Southerby
Matthew Southerby
JKJere Koskela
Jere Koskela
AKAndreas E Kyprianou
Andreas E Kyprianou
Objective: To systematically assess the accuracy and computational performance of a newly proposed stochastic differential equation (SDE)-based model for proton beam dose calculation by benchmarking it against Geant4 in a set of simplified but increasingly challenging phantom geometries. Approach: Building on previous work in Crossley et al. (2025), where energy deposition from a proton beam was modelled using an SDE framework, we implemented the model using standard approximations to interaction cross sections and mean excitation energies, enabling straightforward adaptation to new materials and configurations. The model was benchmarked against Geant4 in homogeneous, longitudinally heterogeneous and laterally heterogeneous phantoms, for assessment of depth-dose behaviour, lateral transport and impact of material heterogeneities. Main results: Across all phantom configurations and beam energies, the SDE model reproduced the main depth–dose characteristics predicted by Geant4, with proton range agreement within 0.2 mm for 100 MeV beams and within 0.6 mm for 150 MeV beams. Voxel-wise comparisons yielded gamma pass rates exceeding 95% for all cases under strict 2%/0.5 mm criteria with a 1% dose threshold. Differences between the two approaches were spatially localised and primarily associated with regions of steep dose gradients or material heterogeneities, while overall lateral beam dispersion was well reproduced. In terms of computational performance, the SDE model achieved speed-up factors of approximately 2.5–3 relative to single-threaded Geant4, consistently across different Geant4 physics lists. Significance: These results demonstrate that the SDE-based approach can reproduce key dosimetric features predicted by high-fidelity Monte Carlo simulations with good accuracy while already offering a moderate reduction in computational cost. Owing to its formulation, the method is naturally amenable to parallel and GPU-accelerated implementations, suggesting potential for substantial further speed improvements. This makes the approach a promising candidate for fast dose calculations in proton therapy.