Rade M. Karamarković

Rade M. Karamarković

Auto-generated profile, based on publicly available information

Rade M. Karamarković

Faculty of Mechanical and Civil Engineering in Kraljevo, University of Kragujevac, Kragujevac, Serbia

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2010 in Energy
Verified
Journal Article
Closed access
RKRade Karamarkovic
Rade Karamarkovic
VKVladan Karamarkovic
Vladan Karamarkovic

1 May 2013 in Applied Thermal Engineering
Verified
Journal Article
Closed access
VKVladan Karamarković
Vladan Karamarković
MMMiljan Radoslav Marasevic
Miljan Radoslav Marasevic
RKRade Karamarković
Rade Karamarković
MKMiodrag Karamarković
Miodrag Karamarković

1 July 2018 in Renewable Energy
Verified
Journal Article
Closed access
VKVladan M. Karamarković
Vladan M. Karamarković
MNMiloš V. Nikolić
Miloš V. Nikolić
RKRade M. Karamarković
Rade M. Karamarković
MKMiodrag V. Karamarković
Miodrag V. Karamarković
MMMiljan R. Marašević
Miljan R. Marašević

1 January 2012 in Thermal Science
Verified
Journal Article
Open access
RKRade Karamarkovic
Rade Karamarkovic
VKVladan Karamarkovic
Vladan Karamarkovic
AJAleksandar Jovovic
Aleksandar Jovovic
MMMiljan Radoslav Marasevic
Miljan Radoslav Marasevic
ALAndjela Lazarevic
Andjela Lazarevic
Due to the irreversibilities that occur during biomass gasification, gasifiers are usually the least efficient units in the systems for production of heat, electricity, or other biofuels. Internal thermal energy exchange is responsible for a part of these irreversibilities and can be reduced by the use of preheated air as a gasifying medium. The focus of the paper is biomass gasification in the whole range of gasification temperatures by the use of air preheated with product gas sensible heat. The energetic and exergetic analyses are carried with a typical ash-free biomass feed represented by CH1.4O0.59N0.0017 at 1 and 10 bar pressure. The tool for the analyses is already validated model extended with a heat exchanger model. For every 200 K of air preheating, the average decrease of the amount of air required for complete biomass gasification is 1.3% of the amount required for its stoichiometric combustion. The air preheated to the gasification temperature on the average increases the lower heating value of the product gas by 13.6%, as well as energetic and exergetic efficiencies of the process. The optimal air preheating temperature is the one that causes gasification to take place at the point where all carbon is consumed. It exists only if the amount of preheated air is less than the amount of air at ambient temperature required for complete gasification at a given pressure. Exergy losses in the heat exchanger, where the product gas preheats air could be reduced by two-stage preheating.

1 January 2017 in Thermal Science
Verified
Journal Article
Open access
PDF file
SKSuzana D. Knežević
Suzana D. Knežević
RKRade M. Karamarković
Rade M. Karamarković
VKVladan M. Karamarković
Vladan M. Karamarković
NSNenad P. Stojić
Nenad P. Stojić
Recuperators are frequently used in glass production and metallurgical processes to preheat combustion air by heat exchange with high temperature flue gases. Mass and energy balances of a 15 m high, concurrent radiant recuperator used in a glass fiber production process are given. The balances are used: for validation of a cell modeling method that predicts the performance of different recuperator designs, and for finding a simple solution to improve the existing recuperator. Three possible solutions are analyzed: to use the existing recuperator as a countercurrent one, to add an extra cylinder over the existing construction, and to make a system that consists of a central pipe and two concentric annular ducts. In the latter, two air streams flow in opposite directions, whereas air in the inner annular passage flows concurrently or countercurrently to flue gases. Compared with the concurrent recuperator, the countercurrent has only one drawback: the interface temperature is higher at the bottom. The advantages are: lower interface temperature at the top where the material is under maximal load, higher efficiency, and smaller pressure drop. Both concurrent and countercurrent double pipe-in-pipe systems are only slightly more efficient than pure concurrent and countercurrent recuperators, respectively. Their advantages are smaller interface temperatures whereas the disadvantages are their costs and pressure drops. To implement these solutions, the average velocities should be: for flue gas around 5 m/s, for air in the first passage less than 2 m/s, and for air in the second passage more than 25 m/s.

8 March 2017 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
ALAndjela Lazarevic
Andjela Lazarevic
VKVladan Karamarkovic
Vladan Karamarkovic
DLDragoljub Lazarevic
Dragoljub Lazarevic
RKRade Karamarkovic
Rade Karamarkovic
The energy sector in Serbia has the highest share in country’s greenhouse gas emissions compared to other sectors that have harmful effects of global warming. Therefore, the energy planning should involve responsible behavior toward natural resources and environment. In order to define necessary measures for emissions reduction, different scenarios were developed, whose projections were made by varying the desired levels of emissions and priorities related to the energy efficiency (EE) and/or renewable energy sources (RES). The structure of primary and final energy consumption was also analyzed under the application of EE measures and measures to increase usage of RES.