Representative Publications

View All Publications
14 January 2022 in Microchimica Acta
Verified
Journal Article
Open access
PDF file
SDSilvia Dortez
Silvia Dortez
TSTania Sierra
Tania Sierra
MÁMiguel Á. Álvarez-Sánchez
Miguel Á. Álvarez-Sánchez
Jose Miguel Gonzalez DominguezJose Miguel Gonzalez Dominguez
Jose Miguel Gonzalez Dominguez
Ana M. BenitoAna M. Benito
Ana M. Benito
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
: Two cellulose nanocrystals/single-walled carbon nanotube (CNC/SW) hybrids, using two cellulose polymorphs, were evaluated as electrochemical transducers: CNC type I (CNC-I/SW) and CNC type II (CNC-II/SW). They were synthesized and fully characterized, and their analytical performance as electrochemical sensors was carefully studied. In comparison with SWCNT-based and screen-printed carbon electrodes, CNC/SW sensors showed superior electroanalytical performance in terms of sensitivity and selectivity, not only in the detection of small metabolites (uric acid, dopamine, and tyrosine) but also in the detection of complex glycoproteins (alpha-1-acid glycoprotein (AGP)). More importantly, CNC-II/SW exhibited 20 times higher sensitivity than CNC-I/SW for AGP determination, yielding a LOD of 7 mg L−1.These results demonstrate the critical role played by nanocellulose polymorphism in the electrochemical performance of CNC/SW hybrid materials, opening new directions in the electrochemical sensing of these complex molecules. In general, these high-active-surface hybrids smartly exploited the preserved non-oxidized SW conductivity with the high aqueous dispersibility of the CNC, avoiding the use of organic solvents or the incorporation of toxic surfactants during their processing, making the CNC/SW hybrids promising nanomaterials for electrochemical detection following greener approaches. Graphical abstract

30 July 2024 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
SDSilvia Dortez
Silvia Dortez
MPMarta Pacheco
Marta Pacheco
TGTERESA GASULL
TERESA GASULL
Agustin G. CrevillenAgustin G. Crevillen
Agustin G. Crevillen
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
A novel microfluidic paper-based analytical device with dual colorimetric and electrochemical detection (dual µPAD) was developed for the assessment of transferrin saturation (TSAT) in samples from ischemic stroke patients. TSAT was calculated by the ratio between transferrin-bound iron, which was colorimetrically measured, and total iron-binding capacity, which was electrochemically measured. To this end, a µPAD was smartly designed with integrated both colorimetric and electrochemical detection reservoirs communicated with and microchannel acting as a chemical reactor and with preloading/storing capabilities (reagent-free device). This approach allowed the dual and simultaneous determination of both parameters, providing an improvement in the reliability and precision of the results benefiting an independent signal principle and processing. µPADs were validated by analyzing a certified reference material showing excellent accuracy (Er ≤ 5 %) and precision (RSD ≤ 2 %) and then they were applied to the analysis of diagnosed serum samples from ischemic stroke patients. The results were compared to those provided by a free-interference method (urea-PAGE). Impressively, both methods exhibited a good correlation (r = 0.96, p < 0.05), and no significant differences were found between both (slope 1.0 ± 0.1 and the intercept 1 ± 4, p < 0.05), demonstrating the excellent accuracy of our approach during the analysis of complex samples from ischemic stroke patients, using just 90 μL of clinical samples and taking less than 90 min in comparison with the 18 hours required by the urea-PAGE approach. The developed fully integrated colorimetric-electrochemical µPAD is a promising ready to be used reagent-free device for the point-of-care testing of TSAT, which can be used to assist physicians in the fast diagnosis and prognosis of ischemic stroke, where the time to decide is crucial for patient’s survival.

24 July 2023 in Analytical Chemistry
Verified
Journal Article
Open access
SDSilvia Dortez
Silvia Dortez
NDNúria DeGregorio-Rocasolano
Núria DeGregorio-Rocasolano
MMMònica Millán
Mònica Millán
TGTERESA GASULL
TERESA GASULL
Agustin G. CrevillenAgustin G. Crevillen
Agustin G. Crevillen
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
For the first time, a paper-based analytical device (PAD) was developed for the assessment of transferrin saturation (TSAT), which is defined as the ratio between iron bound to transferrin (Tf) and the total iron-binding capacity (TIBC) of Tf. Both parameters were simultaneously measured on the same PAD using ferrozine as a chromophore and a smartphone as the color reader. To this end, Tf was first isolated from serum using anti-Tf immunomagnetic beads to ensure that only the Tf-bound iron was measured, improving the selectivity and accuracy of TSAT assessment. To demonstrate the practical utility of the device, it was validated by analyzing a certified reference material, showing excellent accuracy (Er < 4%) and good precision (RSD ≤ 6%). Finally, 18 diagnosed serum samples from ischemic stroke patients were analyzed by this approach, and the results were compared with those obtained by urea-PAGE, showing not only an excellent correlation (r = 0.93, p < 0.05) but that the PAD approach has become statistically identical to the free-interference urea-PAGE. In comparison with the slow, tedious, and non-miniaturized-PAGE, this PAD approach exhibited attractive characteristics such as low cost, disposability, and connectivity, showing great potential for future point-of-care testing, especially in developing countries and/or remote areas, where access to medical or clinical facilities is limited.

7 May 2026 in Microchimica Acta
Verified
Journal Article
Open access
SDSilvia Dortez
Silvia Dortez
MCMiriam Chávez
Miriam Chávez
ACAna Montero Calle
Ana Montero Calle
RBRodrigo Barderas
Rodrigo Barderas
MPMarta Pacheco
Marta Pacheco
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
A paper-based electrochemical aptasensor (PEA) is reported for the simultaneous detection of extracellular dopamine (DA) and serotonin (SE) in human brain samples, enabling the assessment of neurotransmitter imbalances associated with Alzheimer's disease (AD). The PEA integrates a dual-selectivity strategy that combines aptamer-mediated molecular recognition with potential-resolved electrochemical neurotransmitters discrimination, allowing reliable differentiation between healthy and AD-diagnosed left prefrontal cortex tissues based on altered dopaminergic and serotonergic levels. Thiolated aptamers immobilized onto gold nanoparticles (AuNPs) at the paper electrode interface provide selective neurotransmitter biorecognition, while the distinct oxidation potentials of DA (+ 0.10 V) and SE (+ 0.25 V vs. Ag/AgCl) enable their label-free, simultaneous quantification on a single disposable electrode. The PEA read biologically meaningful concentration shifts across a clinically relevant dynamic range, spanning levels characteristic of healthy tissue to those observed in advanced pathological stages. The PEA approach highlights its potential for liquid biopsy-oriented neurochemical monitoring and supports its application in multiplexed biosensing within organ-on-a-chip systems, enabling early diagnostic strategies for neurodegenerative diseases.

20 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
ÁGÁlvaro Gallo-Orive
Álvaro Gallo-Orive
MLMarta Sánchez-Paniagua López
Marta Sánchez-Paniagua López
MMMaría Moreno-Guzmán
María Moreno-Guzmán
SDSilvia Dortez
Silvia Dortez
ARAne San Martin Retegi
Ane San Martin Retegi
AMAlberto Escarpa Miguel
Alberto Escarpa Miguel
A low-cost paper-based analytical device (PAD) was developed for rapid dual detection, integrating an electrochemical PAD (ePAD), which is turbidity-independent, and a smartphone-assisted optical/colorimetric PAD (oPAD). Both platforms employ cerium oxide nanoparticles (nCe) as enzyme-free nanozymes for H₂O₂ detection in 2D and 3D chronic lymphocytic leukemia (CLL) models. The system enables rapid analysis (<1 min) using only 5 µL of sample and exhibits excellent operational stability.The ePAD shows a wide linear range (3 nM–500 µM) with an ultralow detection limit of 0.4 nM, while the oPAD exhibits a detection limit of 0.3 µM within a 1–1000 µM range, both covering physiologically relevant H₂O₂ concentrations. Validation in both 2D cultures and, notably, in 3D CLL co-culture systems incorporating stromal cells—mimicking the architecture and biochemical gradients of the in vivo microenvironment and enhancing cell–cell and cell–matrix interactions—demonstrates the device’s capability to monitor redox dynamics under biologically relevant conditions.Owing to its high sensitivity, low sample requirement, and complementary electrochemical and optical readouts, the nCe-PAD represents a versatile platform for real-time redox profiling, early assessment of oxidative stress, and personalized monitoring in complex tumor microenvironment models, paving the way toward robust point-of-care analytical solutions for redox-related pathologies.