Piotr Put

Piotr Put

Auto-generated profile, based on publicly available information

Piotr Put

Harvard University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2025 in Nature
Verified
Journal Article
Open access
PDF file
HGHaoyang Gao
Haoyang Gao
LMLeigh S. Martin
Leigh S. Martin
LHLillian B. Hughes
Lillian B. Hughes
NLNathaniel T. Leitao
Nathaniel T. Leitao
PPPiotr Put
Piotr Put
MLMikhail D. Lukin
Mikhail D. Lukin
Electronic spins of nitrogen–vacancy centres in diamond constitute a promising system for micro- and nanoscale magnetic sensing1,2,3,4, because of their operation under ambient conditions5, ease of placement in close proximity to sensing targets6 and biological compatibility7. At high densities, the electronic spins interact through dipolar coupling, which typically limits8 but can also potentially enhance9 sensing performance. Here we report the experimental demonstration of many-body signal amplification in a solid-state, room-temperature quantum sensor. Our approach uses time-reversed two-axis-twisting interactions, engineered through dynamical control of the quantization axis and Floquet engineering10 in a two-dimensional ensemble of nitrogen–vacancy centres. We observe that optimal amplification occurs when the backward evolution time equals twice the forward evolution time, in sharp contrast to the conventional Loschmidt echo11,12. These observations can be understood as resulting from an underlying time-reversed mirror symmetry of the microscopic dynamics, providing key insights into signal amplification and opportunities for practical entanglement-enhanced quantum sensing.

22 June 2023 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
PPPiotr Put
Piotr Put
SASeyma Alcicek
Seyma Alcicek
OBOksana Bondar
Oksana Bondar
ŁBŁukasz Bodek
Łukasz Bodek
SDSimon Duckett
Simon Duckett
SPSzymon Pustelny
Szymon Pustelny
Nuclear magnetic resonance (NMR) spectroscopy is a powerful analytical tool used in modern science and technology. Its novel incarnation, based on measurements of NMR signals without external magnetic fields, provides direct access to intramolecular interactions based on heteronuclear scalar J-coupling. The uniqueness of these interactions makes each zero-field NMR spectrum distinct and useful in chemical fingerprinting. However, the necessity of heteronuclear coupling often results in weak signals due to the low abundance of certain nuclei (e.g., 15N). Hyperpolarization of such compounds may solve the problem. In this work, we investigate molecules with natural isotopic abundance that are polarized using non-hydrogenative parahydrogen-induced polarization. We demonstrate that spectra of hyperpolarized naturally abundant pyridine derivatives can be observed and uniquely identified whether the same substituent is placed at a different position of the pyridine ring or different constituents are placed at the same position. To do so, we constructed an experimental system using a home-built nitrogen vapor condenser, which allows for consistent long-term measurements, crucial for identifying naturally abundant hyperpolarized molecules at a concentration level of ~1 mM. This opens avenues for future chemical detection of naturally abundant compounds using zero-field NMR.

4 August 2023 in Communications Chemistry
Verified
Journal Article
Open access
PDF file
SASeyma Alcicek
Seyma Alcicek
PPPiotr Put
Piotr Put
AKAdam Kubrak
Adam Kubrak
FAFatih Celal Alcicek
Fatih Celal Alcicek
DBDanila Barskiy
Danila Barskiy
SPSzymon Pustelny
Szymon Pustelny
Nuclear magnetic resonance (NMR) relaxometry is an analytical method that provides information about molecular environments, even for NMR “silent” molecules (spin-0), by analyzing the properties of NMR signals versus the magnitude of the longitudinal field. Conventionally, this technique is performed at fields much higher than Earth’s magnetic field, but our work focuses on NMR relaxometry at zero and ultra-low magnetic fields (ZULFs). Operating under such conditions allows us to investigate slow (bio)chemical processes occurring on a timescale from milliseconds to seconds, which coincide with spin evolution. ZULFs also minimize T2 line broadening in heterogeneous samples resulting from magnetic susceptibility. Here, we use ZULF NMR relaxometry to analyze (bio)chemical compounds containing 1H-13C, 1H-15N, and 1H-31P spin pairs. We also detected high-quality ULF NMR spectra of human whole-blood at 0.8 μT, despite a shortening of spin relaxation by blood proteomes (e.g., hemoglobin). Information on proton relaxation times of blood, a potential early biomarker of inflammation, can be acquired in under a minute using inexpensive, portable/small-size NMR spectrometers based on atomic magnetometers.

22 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
PPPiotr Put
Piotr Put
KPKacper Popiołek
Kacper Popiołek
SPSzymon Pustelny
Szymon Pustelny
In this article, operation of optical magnetometers detecting static (DC) and oscillating (AC) magnetic fields is studied and comparison of the devices is performed. To facilitate the comparison, the analysis is carried out in the same experimental setup, exploiting nonlinear magneto-optical rotation. In such a system, a control over static-field magnitude or oscillating-field frequency provides detection of strength of the DC or AC fields. Polarization rotation is investigated for various light intensities and AC-field amplitudes, which allows to determine optimum sensitivity to both fields. With the results, we demonstrate that under optimal conditions the AC magnetometer is about ten times more sensitive than its DC counterpart, which originates from different response of the atoms to the fields. Bandwidth of the magnetometers is also analyzed, revealing its different dependence on the light power. Particularly, we demonstrate that bandwidth of the AC magnetometer can be significantly increased without strong deterioration of the magnetometer sensitivity. This behavior, combined with the ability to tune the resonance frequency of the AC magnetometer, provide means for ultra-sensitive measurements of the AC field in a broad but spectrally-limited range, where detrimental role of static-field instability is significantly reduced.

24 October 2025 in Physical Review Letters
Verified
Journal Article
Closed access
XLXuan Hoang Le
Xuan Hoang Le
PDPavel E. Dolgirev
Pavel E. Dolgirev
PPPiotr Put
Piotr Put
EPEric L. Peterson
Eric L. Peterson
APArjun Pillai
Arjun Pillai
MLMikhail D. Lukin
Mikhail D. Lukin
We experimentally demonstrate a method for measuring correlations of wideband magnetic signals with spatial resolution below the optical diffraction limit. Our technique employs two nitrogen-vacancy (NV) centers in diamond as nanoscale magnetometers, spectrally resolved by inhomogeneous optical transitions. Using high-fidelity optical readout and long spin coherence time, we probe correlated megahertz-range noise with sensitivity of 15 nTHz^{-1/4}. In addition, we use this system for correlated T_{1} relaxometry, enabling correlation measurements of gigahertz-range noise. Under such externally applied noise, while individual NV centers exhibit featureless relaxation, their correlation displays rich coherent and incoherent dynamics reminiscent of superradiance physics. This capability to probe high-frequency correlations provides a powerful tool for investigating a variety of condensed-matter phenomena characterized by nonlocal correlations.

22 May 2026 in Physical Review Letters
Verified
Journal Article
Closed access
HGHaoyang Gao
Haoyang Gao
NLNathaniel T. Leitao
Nathaniel T. Leitao
SDSiddharth Dandavate
Siddharth Dandavate
LWLillian B. Hughes Wyatt
Lillian B. Hughes Wyatt
PPPiotr Put
Piotr Put
MLMikhail D. Lukin
Mikhail D. Lukin
In quantum science applications, ranging from many-body physics to quantum metrology, dipolar interactions in spin ensembles are often controlled via Floquet engineering. However, this technique typically reduces the interaction strength between spins and effectively weakens the coupling to a target sensing field, limiting the metrological sensitivity. In this Letter, we develop and demonstrate an alternative method that directly tunes the native dipolar interaction in an ensemble of nitrogen-vacancy (NV) centers in diamond, thereby overcoming these limitations inherent to Floquet engineering. Our approach utilizes dressed-state qubit encoding under a bias magnetic field applied perpendicular to the crystal lattice orientation. This method leads to a 3.2× enhancement of the dimensionless coherence parameter JT_{2} compared to state-of-the-art Floquet engineering and a 2.6× (8.3 dB) enhanced sensitivity in ac magnetometry. Our results provide a powerful Hamiltonian engineering tool for future studies with NV ensembles and other interacting higher-spin (S>1/2) systems.