Ananta Raj Chalise

Ananta Raj Chalise

Auto-generated profile, based on publicly available information

Ananta Raj Chalise

University of Maryland, Baltimore

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
Youfang LaiYoufang Lai
Youfang Lai
YZYuncheng Zhong
Yuncheng Zhong
ACAnanta Raj Chalise
Ananta Raj Chalise
YSYiping Shao
Yiping Shao
MJMingwu Jin
Mingwu Jin
YCYujie Chi
Yujie Chi
Monte Carlo (MC) simulation method plays an essential role in the refinement and development of positron emission tomography (PET) systems. However, most existing MC simulation packages suffer from long execution time for practical PET simulations. To fully address this issue, we developed and validated gPET, a graphics processing unit (GPU)-based MC simulation tool for PET. gPET was built on the NVidia CUDA platform. The simulation process was modularized into three functional parts and carried out by the GPU parallel threads: (1) source management, including positron decay, transport and annihilation; (2) gamma transport inside the phantom; and (3) signal detection and processing inside the detector. A hybrid of voxelized (for patient phantoms) and parametrized (for detectors) geometries were employed to sufficiently support particle navigations. Multiple inputs and outputs were available. Hence, a user can flexibly examine different aspects of a PET simulation. We evaluated the performance of gPET in three test cases with benchmark work from GATE8.0, in terms of the testing of the functional modules, the physics models used for gamma transport inside the detector, and the geometric configuration of an irregularly shaped PET detector. Both accuracy and efficiency were quantified. In all test cases, the differences between gPET and GATE for the coincidences with respect to the energy and crystal index distributions are below 3.18% and 2.54%, respectively. The speedup factor is 500 for gPET on a single Titan Xp GPU (1.58 GHz) over GATE8.0 on a single core of Intel i7-6850K CPU (3.6 GHz) for all test cases. In summary, gPET is an accurate and efficient MC simulation tool for PET.

1 November 2018
Verified
Conference Paper
Closed access
YCYujie Chi
Yujie Chi
ACAnanta Chalise
Ananta Chalise
YSYiping Shao
Yiping Shao
MJMingwu Jin
Mingwu Jin
In this study, we investigate the prompt gamma yields of two carbon ion species, C-11 and C-12, in the therapeutic beam energy range (95MeV u-1 ~ 300MeV u-1 with regarding to the C-12 beam). For head-to-head comparison, Monte Carlo simulations for mono-energetic pencil incident beams were performed in three energy levels. Beam transportations inside a fixed size water phantom were governed by Geant4 Monte Carlo package and the QGSP_BIC_HP model. Dose distributions, prompt gamma phase space files including energy, time of flight (TOF), position, direction and yield process were recorded. To obtain a dose distribution sensitizer, energy cutoff and TOF windowing were applied to raw prompt gamma data. Depth dose profiles and prompt gamma distributions were then compared. Generally, the absolute yield of the prompt gamma yield per incident C-12 ion is slightly higher than that per C-11 ion. However, the depth distribution of prompt gamma from the C-11 ions seem to be narrower at the Bragg peak region when a tight TOF applied, which may indicate a higher sensitivity to the dose distribution. With regarding to the specific yield processes, prompt gamma from the ion inelastic process is of dominance in both C-11 and C-12 beams. Slightly different depth distributions of gammas from this process was also observed for C-11and C-12. Besides, C-11 has a slight proto This study shows that the C-11 ion beam can provide a comparable prompt gamma yield to, if not better than, the C-12 beam with respect to the dose profile. The C-11 ion beam may serve as a reporter for both prompt gamma imaging and positron emission tomography (PET) for online dose monitoring.

29 September 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
ACAnanta Raj Chalise
Ananta Raj Chalise
YCYujie Chi
Yujie Chi
YLYoufang Lai
Youfang Lai
YSYiping Shao
Yiping Shao
MJMingwu Jin
Mingwu Jin
Range uncertainty remains a big concern in particle therapy, as it may cause target dose degradation and normal tissue overdosing. Positron emission tomography (PET) and prompt gamma imaging (PGI) are two promising modalities for range verification. However, the relatively long acquisition time of PET and the relatively low yield of PGI pose challenges for real-time range verification. In this paper, we explore using the primary Carbon-11 (C-11) ion beams to enhance the gamma yield compared to the primary C-12 ion beams to improve PET and PGI by using Monte Carlo simulations of water and PMMA phantoms at four incident energies (95, 200, 300, and 430 MeV u −1 ). Prompt gammas (PGs) and annihilation gammas (AGs) were recorded for post-processing to mimic PGI and PET imaging, respectively. We used both time-of-flight (TOF) and energy selections for PGI, which boosted the ratio of PGs to background neutrons to 2.44, up from 0.87 without the selections. At the lowest incident energy (100 MeVu -1 ), PG yield from C-11 was 0.82 times of that from C-12, while AG yield from C-11 was 6 ∼ 11 folds higher than from C-12 in PMMA. At higher energies, PG differences between C-11 and C-12 were much smaller, while AG yield from C-11 was 30%∼90% higher than from C-12 using minute-acquisition. With minute-acquisition, the AG depth distribution of C-11 showed a sharp peak coincident with the Bragg peak due to the decay of the primary C-11 ions, but that of C-12 had no such one. The high AG yield and distinct peaks could lead to more precise range verification of C-11 than C-12. These results demonstrate that using C-11 ion beams for potentially combined PGI and PET has great potential to improve online single-spot range verification accuracy and precision.

1 November 2026 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
VSV. R. Sharma
V. R. Sharma
ESE. Shakeri
E. Shakeri
ZJZ. Jiang
Z. Jiang
SMS. Mossahebi
S. Mossahebi
ACA. Chalise
A. Chalise
LRLei Ren
Lei Ren
This study presents a novel simulation study for integrating four Compton Cameras (CC) into proton therapy systems by mounting them directly on the snout of the treatment gantry for prompt gamma imaging (PGI). This compact, fixed geometry simplifies detector integration, maintains alignment with the proton beam axis, and supports in vivo proton range verification. A Geant4-based Monte Carlo framework, PJ-MC, was used to simulate prompt gamma emissions (PGE) in water and patient-specific geometry. PG image reconstruction was performed using the Kernel Weighted Back Projection (KWBP) algorithm. To improve range accuracy, we introduced a post-processing method called Point Source Normalization (PSN), which uses precomputed PGI responses for monoenergetic gamma point sources at different depths to normalize PGI images and correct distortions from attenuation, geometric factors, and detector responses from PGE detected curve. Simulations with monoenergetic sources confirmed the influence of depth-dependent attenuation and inverse square losses, especially at higher proton energies. Clinical beam energies of 70, 150, and 200 MeV were tested. KWBP reconstructions showed increasing range discrepancies with energy, reaching 176 mm (water) and 144 mm (patient) at 200 MeV. PSN correction reduced these errors by up to 70%, bringing PG hotspots closer to the Bragg peak (Dmax). Simulations with anterior/posterior shifts showed that the PSN-corrected system could detect millimeter-scale range deviations from setup uncertainties and beam shifts. This is the first study to simulate and evaluate a snout-mounted CC system for PGI in proton therapy. Results support future validation under clinical beam conditions in phantoms and patients.