Yujie Chi

Prof. Dr. Yujie Chi

Physics, The University of Texas at Arlington, Arlington, Massachusetts, USA
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
YLYoufang Lai
Youfang Lai
XJXun Jia
Xun Jia
YCYujie Chi
Yujie Chi
Oxygen plays a critical role in determining the initial DNA damages induced by ionizing radiation. It is important to mechanistically model the oxygen effect in the water radiolysis process. However, due to the computational costs from the many body interaction problem, oxygen is often ignored or treated as a constant continuum radiolysis-scavenger background in the simulations using common microscopic Monte Carlo tools. In this work, we reported our recent progress on the modeling of the chemical stage of the water radiolysis with an explicit consideration of the oxygen effect, based upon our initial development of an open-source graphical processing unit (GPU)-based MC simulation tool, gMicroMC. The inclusion of oxygen mainly reduces the yields of e h and H . chemical radicals, turning them into highly toxic O 2 . − and H O 2 . species. To demonstrate the practical value of gMicroMC in large scale simulation problems, we applied the oxygen-simulation-enabled gMicroMC to compute the yields of chemical radicals under a high instantaneous dose rate D ˙ i to study the oxygen depletion hypothesis in FLASH radiotherapy. A decreased oxygen consumption rate (OCR) was found associated with a reduced initial oxygen concentration level due to reduced probabilities of reactions. With respect to dose rate, for the oxygen concentration of 21% and electron energy of 4.5 k e V , OCR remained approximately constant (∼0.22 μ M   G y − 1 ) for D ˙ i ’s of 10 6 , 10 7   G y s − 1 and reduced to 0.19 μ M   G y − 1 at 10 8   G y s − 1 , because the increased dose rate improved the mutual reaction frequencies among radicals, hence reducing their reactions with oxygen. We computed the time evolution of oxygen concentration under the FLASH irradiation setups. At the dose rate of 10 7   G y s − 1 and initial oxygen concentrations from 0.01% to 21%, the oxygen is unlikely to be fully depleted with an accumulative dose of 30 Gy, which is a typical dose used in FLASH experiments. The computational efficiency of gMicroMC when considering oxygen molecules in the chemical stage was evaluated through benchmark work to GEANT4-DNA with simulating an equivalent number of radicals. With an initial oxygen concentration of 3% (∼10 5 molecules), a speedup factor of 1228 was achieved for gMicroMC on a single GPU card when comparing with GEANT4-DNA on a single CPU.

23 January 2020 in Medical Physics
Verified
Journal Article
Closed access
PDF file
MTMin‐Yu Tsai
Min‐Yu Tsai
ZTZhen Tian
Zhen Tian
NQNan Qin
Nan Qin
CYCongchong Yan
Congchong Yan
YLYoufang Lai
Youfang Lai
XJXun Jia
Xun Jia

9 March 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Youfang LaiYoufang Lai
Youfang Lai
QWQian Wang
Qian Wang
SZShiwei Zhou
Shiwei Zhou
ZXZhaoheng Xie
Zhaoheng Xie
JQJinyi Qi
Jinyi Qi
JDJunwei Du
Junwei Du
With the goal of developing a total-body small-animal PET system with a high spatial resolution of ∼0.5 mm and a high sensitivity >10% for mouse/rat studies, we simulated four scanners using the graphical processing unit-based Monte Carlo simulation package (gPET) and compared their performance in terms of spatial resolution and sensitivity. We also investigated the effect of depth-of-interaction (DOI) resolution on the spatial resolution. All the scanners are built upon 128 DOI encoding dual-ended readout detectors with lutetium yttrium oxyorthosilicate (LYSO) arrays arranged in 8 detector rings. The solid angle coverages of the four scanners are all ∼0.85 steradians. Each LYSO element has a cross-section of 0.44 × 0.44 mm 2 and the pitch size of the LYSO arrays are all 0.5 mm. The four scanners can be divided into two groups: (1) H 2 RS110-C10 and H 2 RS110-C20 with 40 × 40 LYSO arrays, a ring diameter of 110 mm and axial length of 167 mm, and (2) H 2 RS160-C10 and H 2 RS160-C20 with 60 × 60 LYSO arrays, a diameter of 160 mm and axial length of 254 mm. C10 and C20 denote the crystal thickness of 10 and 20 mm, respectively. The simulation results show that all scanners have a spatial resolution better than 0.5 mm at the center of the field-of-view (FOV). The radial resolution strongly depends on the DOI resolution and radial offset, but not the axial resolution and tangential resolution. Comparing the C10 and C20 designs, the former provides better resolution, especially at positions away from the center of the FOV, whereas the latter has 2× higher sensitivity (∼10% versus ∼20%). This simulation study provides evidence that the 110 mm systems are a good choice for total-body mouse studies at a lower cost, whereas the 160 mm systems are suited for both total-body mouse and rat studies.

13 December 2019 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
Youfang LaiYoufang Lai
Youfang Lai
YZYuncheng Zhong
Yuncheng Zhong
ACAnanta Raj Chalise
Ananta Raj Chalise
YSYiping Shao
Yiping Shao
MJMingwu Jin
Mingwu Jin
YCYujie Chi
Yujie Chi
Monte Carlo (MC) simulation method plays an essential role in the refinement and development of positron emission tomography (PET) systems. However, most existing MC simulation packages suffer from long execution time for practical PET simulations. To fully address this issue, we developed and validated gPET, a graphics processing unit (GPU)-based MC simulation tool for PET. gPET was built on the NVidia CUDA platform. The simulation process was modularized into three functional parts and carried out by the GPU parallel threads: (1) source management, including positron decay, transport and annihilation; (2) gamma transport inside the phantom; and (3) signal detection and processing inside the detector. A hybrid of voxelized (for patient phantoms) and parametrized (for detectors) geometries were employed to sufficiently support particle navigations. Multiple inputs and outputs were available. Hence, a user can flexibly examine different aspects of a PET simulation. We evaluated the performance of gPET in three test cases with benchmark work from GATE8.0, in terms of the testing of the functional modules, the physics models used for gamma transport inside the detector, and the geometric configuration of an irregularly shaped PET detector. Both accuracy and efficiency were quantified. In all test cases, the differences between gPET and GATE for the coincidences with respect to the energy and crystal index distributions are below 3.18% and 2.54%, respectively. The speedup factor is 500 for gPET on a single Titan Xp GPU (1.58 GHz) over GATE8.0 on a single core of Intel i7-6850K CPU (3.6 GHz) for all test cases. In summary, gPET is an accurate and efficient MC simulation tool for PET.

23 January 2020 in Medical Physics
Verified
Journal Article
Closed access
PDF file
YLYoufang Lai
Youfang Lai
MTMin‐Yu Tsai
Min‐Yu Tsai
ZTZhen Tian
Zhen Tian
NQNan Qin
Nan Qin
CYCongchong Yan
Congchong Yan
XJXun Jia
Xun Jia

3 June 2022 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
DSDamon Sprouts
Damon Sprouts
YGYin Gao
Yin Gao
CWChao Wang
Chao Wang
XJXun Jia
Xun Jia
CSChenyang Shen
Chenyang Shen
YCYujie Chi
Yujie Chi
Although commercial treatment planning systems (TPSs) can automatically solve the optimization problem for treatment planning, human planners need to define and adjust the planning objectives/constraints to obtain clinically acceptable plans. Such a process is labor-intensive and time-consuming. In this work, we show an end-to-end study to train a deep reinforcement learning (DRL) based virtual treatment planner (VTP) that can behave like a human to operate a dose-volume constrained treatment plan optimization engine following the parameters used in Eclipse TPS for high-quality treatment planning. We considered the prostate cancer IMRT treatment plan as the testbed. The VTP took the dose-volume histogram (DVH) of a plan as input and predicted the optimal strategy for constraint adjustment to improve the plan quality. The training of VTP followed the state-of-the-art Q-learning framework. Experience replay was implemented with epsilon-greedy search to explore the impacts of taking different actions on a large number of automatically generated plans, from which an optimal policy can be learned. Since a major computational cost in training was to solve the plan optimization problem repeatedly, we implemented a graphical processing unit (GPU)-based technique to improve the efficiency by 2-fold. Upon the completion of training, the established VTP was deployed to plan for an independent set of 50 testing patient cases. Connecting the established VTP with the Eclipse workstation via the application programming interface, we tested the performance the VTP in operating Eclipse TPS for automatic treatment planning with another two independent patient cases. Like a human planner, VTP kept adjusting the planning objectives/constraints to improve plan quality until the plan was acceptable or the maximum number of adjustment steps was reached under both scenarios. The generated plans were evaluated using the ProKnow scoring system. The mean plan score (± standard deviation) of the 50 testing cases were improved from 6.18 ± 1.75 to 8.14 ± 1.27 by the VTP, with 9 being the maximal score. As for the two cases under Eclipse dose optimization, the plan scores were improved from 8 to 8.4 and 8.7 respectively by the VTP. These results indicated that the proposed DRL-based VTP was able to operate the in-house dose-volume constrained TPS and Eclipse TPS to automatically generate high-quality treatment plans for prostate cancer IMRT.