Nor Adrian Nor Salim

Nor Adrian Nor Salim

Auto-generated profile, based on publicly available information

Nor Adrian Nor Salim

Industrial and Indoor Environment Research Group, Fakulti Kejuruteraan Mekanikal dan Pembuatan, Universiti Tun Hussein Onn Malaysia, 86400 Parit Raja, Johor, Malaysia

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2021 in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Verified
Journal Article
Open access
PDF file
NSNor Adrian Nor Salim
Nor Adrian Nor Salim
NANorzelawati Asmuin
Norzelawati Asmuin
AHAzian Hariri
Azian Hariri
MSM. Farid Sies
M. Farid Sies
HZHanis Zakaria
Hanis Zakaria
AAAHMAD MUBARAK TAJUL ARIFIN
AHMAD MUBARAK TAJUL ARIFIN
A Water-mist spray system in several heavy-duty kitchen hood canopies is installed to efficiently control the high heat loads and grease emissions produced from the cooking process and for safety purposes. The main purpose of this study is to reduce water consumption by introducing the water-mist recirculation system to replace the current method water-mist system since it is working as water loss. A standard ASTM 2519 and UL 1046 full-scaled experiment is developed in the laboratory. An existing Halton Europe/Asian water-mist operating system is adopted in this study. Twelve (12) cycles (at 24 hours of water-mist activation) have been studied to determine the maximum water-mist activation cycle. The data are collected at two (2) hours water-mist activation at every water-mist recirculation cycle. The water-mist spray fluids viscosity is 0.7 cP from fresh water until the 4th cycle (8 hours water-mist spray) and increase 14.29% (0.8 cP) at the 5th cycle to the 12th cycle. On average, the difference in gas emissions percentage for CO concentration between fresh water until the 4th cycle is 10.81 – 18.92% while the CO2 concentration is 12.33 – 18.22%. On average, the difference in cooling effects percentage for ducting temperature between fresh water until the 4th cycle is 5.55% while the hood temperature is 2.33%. From the study, the water-mist recirculation system could save up to 611,667 litres per year and 466,798.5 litres per year water for all U.S, European, and Asian kitchen hood designs per hood length. By adopting the new water-mist recirculation system to the current water-mist kitchen hood, the water operational cost for water successfully reduced to RM 4,889.63 per year and RM 6,977.86 per year for U.S design and European or Asian design per hood length respectively. The water-mist recirculation system has great potential to improve the current water-mist system for the commercial kitchen hood.