Julian Kang

Julian Kang

Auto-generated profile, based on publicly available information

Julian Kang

Department of Construction Science, Texas A&M University, College Station, TX 77843, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2015 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
VFVahid Faghihi
Vahid Faghihi
ANAli Nejat
Ali Nejat
KRKenneth F. Reinschmidt
Kenneth F. Reinschmidt
JKJulian H. Kang
Julian H. Kang

1 June 2007 in Journal of Construction Engineering and Management
Verified
Journal Article
Closed access
JKJulian H. Kang
Julian H. Kang
SAStuart D. Anderson
Stuart D. Anderson
MCMark J. Clayton
Mark J. Clayton
This paper reports an empirical study that tested the usefulness of Web-based four-dimensional (4D) construction visualization in collaborative construction planning and scheduling. Several recent construction projects have employed 4D visualization to better understand the construction schedule and make proactive decisions to prevent logical errors in the construction sequence. Other groups have shown that construction information management with asynchronous Web-based communication can improve decision making among dispersed industry practitioners. It seems reasonable to anticipate that combining 4D visualization with Web-based information management would facilitate dispersed industry practitioners to make collaborative decisions for construction planning and scheduling. The empirical study presented here reports how experiment participants at separate locations collaboratively detected logical errors in a construction schedule when the 4D visualization model of the schedule was represented on the Web ...

27 July 2019 in Materials
Verified
Journal Article
Open access
PDF file
Jaeheum YeonJaeheum Yeon
Jaeheum Yeon
Yooseob SongYooseob Song
Yooseob Song
KKKwan-Kyu Kim
Kwan-Kyu Kim
JKJulian Kang
Julian Kang
In the construction field, adhesives are frequently used to improve adhesion between two objects. Epoxy adhesives are applied as long-term solutions, improving the bond between repair materials and existing concrete structures. Experimental investigations of the relationship between the thickness of an adhesive layer and its shear strength have been conducted by a number of industries outside of the construction sector. However, that research used metal plates as adherends when determining the shear strengths of epoxy adhesives. Therefore, this study examines epoxy adhesives’ shear strength development when applied to concrete adherends. The test results show that the thickness of the bond layer did affect shear strength development in the epoxy adhesives examined.

28 March 2023 in Computers in Human Behavior
Verified
Journal Article
Closed access
JKJulian H. Kang
Julian H. Kang
NYNeeraj Yadav
Neeraj Yadav
SRSiva Ramadoss
Siva Ramadoss
Jaeheum YeonJaeheum Yeon
Jaeheum Yeon

20 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
NYNeeraj Yadav
Neeraj Yadav
NSNeda Sadeghi
Neda Sadeghi
JKJulian Kang
Julian Kang
High auditory noise levels and limited visibility are often considered among the main factors that hinder seamless communication on construction sites. Many previous research studies have leveraged technology to overcome these obstacles and communicate using the hearing, sight and touch senses. However, the technological efficacy does not secure the users’ perceptivity of the wireless communication devices. Statistical data regarding the number of fatal accidents on construction sites have remained steady despite regular efforts. This study analyzed prior research on wearable safety promotion devices for personnel that move around the jobsite on foot. A seven-point checklist was utilized to shortlist prior studies (2005–2021) attempting to provide safety information wirelessly to the construction workers-on-foot. The reasoning behind various on-body placements was investigated along with the information conveyed using the three communication modalities. A novel communication network is also introduced to visualize the technical details. Lastly, limitations and future recommendations have been presented to gain insights about the factors that might affect the placement of the wearable safety promotion devices.

30 September 2010 in JOURNAL OF CIVIL ENGINEERING AND MANAGEMENT
Verified
Journal Article
Open access
JKJulian H. Kang
Julian H. Kang
JGJasdeep Gandhi
Jasdeep Gandhi
Concrete maturity technology is used to predict the strength of concrete being cured and make an informed decision for stripping the formworks. However, the current concrete maturity method uses temperature sensors that require an extensive wiring, which is not often acceptable on construction site due to harsh working environment. Radio Frequency Identification (RFID) technology provides a solution for the wiring issue because of its ability of sending data wirelessly. An RFID tag integrated with a temperature sensor and placed within fresh concrete may be able to read temperatures of concrete and transmit them to an RFID reader wirelessly in real‐time. It may then enable construction professionals to use concrete maturity technology to make an informed decision for stripping the formworks without having to worry about wiring issues on construction site. However, the previous research indicated that the RFID signal gets dispersed in liquid medium. One may speculate then how well RFID signals can travel through fresh concrete with high water content. Would water content of fresh concrete affect the readability of RFID tags? Would the tag's burying depth within fresh concrete affect its readability? This paper presents the results of our investigation on the readability of RFID tags placed in fresh concrete in the early stage of the curing process. Santrauka Betono stiprejimo technologija taikoma apdorojamo betono stiprumui prognozuoti priimant sprendima, kada galima nuimti klojinius. Vadovaujantis betono stiprejimo kontroles metodu, naudojami temperatūros jutikliai, prijungiami laidais, kuriuos ne visada patogu naudoti sunkiomis statybos aikšteles salygomis. Laidu galima atsisakyti taikant radijo dažnio nustatymo (RDN) technologija, nes ji leidžia siusti duomenis be laidu. RND siustuvas, pritvirtintas prie temperatūros jutiklio ir idetas i šviežia betona, gali matuoti betono temperatūra ir perduoti jos reikšmes i RND imtuva be jokiu laidu. Remiantis tokia informacija galima spresti, kada nuimti klojinius nesukeliant rūpesčiu su jutikliu laidais. Tačiau ankstesni tyrimai parode, kad skystoje aplinkoje RDN signalas išsklaidomas. Galima tik speti, kaip šis signalas sklis šviežio betono aplinkoje. Ar tokiame betone esantis vanduo leis skaityti RND siustuvu informacija? Ar siustuvo gylis šviežiame betone komplikuos jo informacijos skaitymo galimybe? Šiame straipsnyje aprašomi RND siustuvu informacijos tyrimo rezultatai, gauti idejus siustuvus ankstyvuoju šviežio betono stiprejimo laikotarpiu.