Darko Šuka

Darko Šuka

Auto-generated profile, based on publicly available information

Darko Šuka

University of East Sarajevo

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Open access
PDF file
DŠDarko Šuka
Darko Šuka
PPPredrag Pejović
Predrag Pejović
MSMirjana Simić-Pejović
Mirjana Simić-Pejović
Since EMF levels from wireless telecommunication networks are non-stationary and exhibit large temporal variations, the use of continuous measurements during extended periods (preferably 24 h or longer) with a data-logging system is required. Because of the short-term variations of E field, the 6-min measurements and 6-min averaged results to obtain the mean level strength at a given place appear to be dependent on the time of measurements during the day. This paper presents a new (integral-based) measure to evaluate electromagnetic exposure. The new measure is a pure physical descriptor of the amount of exposed energy density (a parameter accumulated from instantaneous power density values in time). To confirm previous observations, continuous measurements with personal exposure metre were recorded 24 h a day for two weeks at every location in urban area, 14 different locations in total. Additionally, to check temporal variations and repeatability of exposure assessment, a week of prolonged measurements was taken 6 months later, making in total three weeks of measurements at 2 locations. Day-to-day repeatability of RF-EMF exposure was analysed through the time-averaged and integral-based measure. The analysis is based on approximately 5.1 million data samples (1.7 million for each band). The ratio between the maximum and minimum instantaneous (maximum and minimum 6-min averaged) E field values during the day could reach up to 25 dB (20 dB). Therefore, great variability in the results may occur. By applying the 24 h time-averaged and integral-based measure on a 24 h data set of measurements, the variability of daily exposure could stay within ±20% of the week mean level obtained either with the time-averaged or integral-based measure. Both, the time-averaged E field and integral-based power density exposures of the general public in all locations were found to be well below the general public exposure limits of the ICNIRP guidelines.

22 August 2024 in IEEE Access
Verified
Journal Article
Open access
SWSangin Qahtan Wali
Sangin Qahtan Wali
ASADUWATI SALI
ADUWATI SALI
DŠDarko Šuka
Darko Šuka
Sam AertsSam Aerts
Sam Aerts
MAMohammed Alkurayşi
Mohammed Alkurayşi
AOAnwar Faizd Osman
Anwar Faizd Osman
This study evaluates the maximum theoretical exposure to radiofrequency (RF) electromagnetic fields (EMFs) from a Fifth-generation (5G) New Radio (NR) base station (BS) while using four commonly used mobile applications: YouTube for video streaming, WhatsApp for voice calls, Instagram for posting pictures and videos, and running a Video game. Three factors that might affect exposure, i.e., distance of the measurement positions from the BS, measurement time, and induced traffic, were examined. Exposure was assessed through both instantaneous and time-averaged extrapolated field strengths using the Maximum Power Extrapolation (MPE) method. The former was calculated for every measured SS-RSRP (Secondary Synchronization Reference Signal Received Power) power sample obtained with a sampling resolution of 1 second, whereas the latter was obtained using a 1-min moving average applied on the applications’ instantaneous extrapolated field strengths datasets. Regarding distance, two measurement positions (MPs) were selected: MP1 at 56 meters and MP2 at 170 meters. Next, considering the measurement time, all mobile application tests were initially set to run for 30 minutes at both MPs, whereas the video streaming test (YouTube) was run for an additional 150 minutes to investigate the temporal evolution of field strengths. Considering the traffic, throughput data vs. both instantaneous and time-averaged extrapolated field strengths were observed for all four mobile applications. In addition, at MP1, a 30-minute test without a User Equipment (UE) device was conducted to analyze exposure levels in the absence of induced traffic. The findings indicated that the estimated field strengths for mobile applications varied. It was observed that distance and time had a more significant impact than the volume of data traffic generated (throughput). Notably, the exposure levels in all tests were considerably lower than the public exposure thresholds set by the ICNIRP guidelines.

1 June 2020 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
DŠDarko Šuka
Darko Šuka
PPPredrag Pejović
Predrag Pejović
MSMirjana Simić-Pejović
Mirjana Simić-Pejović
Since radio frequency (RF) signals from public mobile systems are stochastic and exhibit large temporal variations, the results of measurements, typically E field measurements, are time dependent and highly variable. Therefore, any 6-min measurements and 6-min averaged results to obtain the mean level strength at a given place may not be so reliable when it comes to determine long-term exposure levels. Specifically, the results of such short-term exposure assessments can be both under- or overestimated depending on whether the extreme value is caught during the measurement time. Because the RF range is active 24 h a day, the authors suggest that the monitoring process should cover the same time period. To evaluate the variability of measurement results, the analysis in this paper was conducted through descriptive statistics of the 24-h instantaneous, time-averaged and integral-based values. By applying the 24-h time-averaged and integral-based measure on a 24-h data set of measurements, the variability of daily exposure could be reduced to ±20% of the mean week value obtained either with the time-averaged or integral-based measure.

1 June 2022 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
DŠDarko Šuka
Darko Šuka
MSMirjana Simić-Pejović
Mirjana Simić-Pejović
PPPredrag Pejović
Predrag Pejović
Exposure assessment should consider the stochastic nature of the emitted signals. Therefore, the long-term temporal variability of E-field strength, obtained by band selective measurements for long-term evolution in a real mobile network environment, is considered in this paper. Intensive measurements were carried out 24 h a day for 2 weeks at an indoor location in the urban area. The repeatability of the measurement results was achieved through descriptive statistics of the 24-h instantaneous, time-averaged and integral-based values. More specifically, we addressed the uncertainties on the temporal variability of the instantaneous exposure levels and the effects of duration of averaging and time-integrating on it. To this aim, a huge amount of signal levels (120 960 samples) was collected during the measurement campaign by considering three operators in the 800 MHz downlink band. Results have shown how some factors, such as the time interval in which the measurements are taken, can significantly affect the measurement results and their repeatability. Furthermore, in some cases, such effects become comparable to, or even larger than typical measurement uncertainty. By applying both the 24-h time-averaged and integral-based measure, the variability of daily exposure levels could be reduced to values lower than the measurement uncertainty (i.e. lower than ± 20% of the mean week value obtained with either measure). Based on such results, an indicator depending on the exposure duration should better quantify the far-field exposure in each location.

1 March 2020
Verified
Conference Paper
Closed access
DSDarko S. Suka
Darko S. Suka
MSMirjana I. Simic-Pejovic
Mirjana I. Simic-Pejovic
PPPredrag V. Pejovic
Predrag V. Pejovic
This paper discusses the software simulations of RF electromagnetic fields (EMFs) distribution for an outdoor scenario in a densely populated urban area, the practical realization of simulations and the comparative analysis of simulation and measurement results. The goal was to predict the EMF strength with a slightly different approach in relation to the mobile operators who are focused on the planning of area coverage to support the voice and data traffic at a level of quality expected by the users. In this regard, Wireless InSite® software has been used to estimate the maximum values of the EMF total power density distribution and E rms strengths caused by the radiation of all base stations in the observed area.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ABAndrea Bernieri
Andrea Bernieri
Giovanni BettaGiovanni Betta
Giovanni Betta
Domenico CapriglioneDomenico Capriglione
Domenico Capriglione
Gianni CerroGianni Cerro
Gianni Cerro
Gianfranco MieleGianfranco Miele
Gianfranco Miele
DSDarko Suka
Darko Suka