Ruth Lapid-Gortzak

Ruth Lapid-Gortzak

Auto-generated profile, based on publicly available information

Ruth Lapid-Gortzak

Ophthalmology, Amsterdam UMC, Amsterdam, the Netherlands

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
VVViolette Vrijman
Violette Vrijman
JLJan Willem van der Linden
Jan Willem van der Linden
CNCarla P. Nieuwendaal
Carla P. Nieuwendaal
IMIvanka J.E. van der Meulen
Ivanka J.E. van der Meulen
MMMaarten P. Mourits
Maarten P. Mourits
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak
PURPOSE: To evaluate the effect on refraction of neodymium:YAG (Nd:YAG) laser posterior capsulotomy for posterior capsule opacification (PCO), and to evaluate the correlation between automated and subjective refraction in multifocal apodized diffractive pseudophakia. METHODS: A retrospective study of 75 pseudophakic eyes (50 patients) with multifocal apodized diffractive pseudophakia, treated for PCO with Nd:YAG laser posterior capsulotomy, was performed. Pre- and postintervention values of refractive and visual parameters were compared. The outcomes of autorefraction and subjective refraction were also compared. RESULTS: Uncorrected and corrected distance visual acuity improved significantly after Nd:YAG capsulotomy ( P< .001). No significant changes were noted in defocus equivalent, astigmatic power vectors J 0 and J 45 , and overall blurring strength in subjective refraction and autorefraction. Spherical equivalent changed significantly in autorefraction ( P =.008), but not in subjective refraction. Autorefraction and subjective refraction were highly correlated in spherical equivalent, defocus equivalent, and blurring strength (r 2 >0.59). In approximately 7% of eyes, a change of more than 0.50 diopters in spherical equivalent in subjective refraction occurred. CONCLUSIONS: In most cases, Nd:YAG laser capsulotomy in patients with multifocal pseudophakia did not result in a change in refraction. However, 7% of eyes experienced a significant change in subjective refraction. Autorefraction correlated well with subjective refraction in apodized diffractive multifocal IOLs.

11 March 2022 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
AAAdi Shacham Abulafia
Adi Shacham Abulafia
GBGraham D. Barrett
Graham D. Barrett
APAdi Porat-Rein
Adi Porat-Rein
MTMaria Tsessler
Maria Tsessler
DZDavid Zadok
David Zadok
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak

5 November 2024 in Cornea
Verified
Journal Article
Open access
ODOfer Daphna
Ofer Daphna
GAGerd U. Auffarth
Gerd U. Auffarth
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak
SCSunita Chaurasia
Sunita Chaurasia
EGEfrat Msc Gilboa
Efrat Msc Gilboa
AMArie Marcovich
Arie Marcovich
Purpose: The purpose of this study was to report the safety and efficacy results of an artificial lamellar implant for the treatment of chronic corneal edema. Methods: The EndoArt (EyeYon Medical, Ness Ziona, Israel), an artificial endothelial replacement membrane designed to treat corneal edema, was implanted in 24 eyes of 24 patients with low-to-normal visual potential. We present the safety and efficacy results from a prospective, open-label, single-arm, multicenter study conducted over a 12-month period. Results: Twenty-four patients were enrolled, with no device-related serious adverse events reported. Seventeen patients completed 12-month follow-up, showing a reduction in average central corneal thickness from 759 ± 116 μm to 613 ± 135 μm. Best-corrected distance visual acuity improved from 1.88 ± 0.79 logarithmic minimum angle of resolution (logMAR) to 1.34 ± 0.57 logMAR. Sixty percent gained at least 3 early treatment diabetic retinopathy study (ETDRS) lines. The EndoArt was removed in 5 cases due to incomplete attachment and replaced by corneal transplants; 1 patient was lost to follow-up, and 1 had a procedure failure. No device-related long-term complications, infections, or inflammations were reported. The implants remained transparent throughout the study. Conclusions: The first-in-human results of EndoArt implantation demonstrated the device's potential to treat patients suffering from corneal edema with a favorable safety profile and effective edema reduction in most subjects, with no device-related serious adverse event. The EndoArt may offer a viable solution in regions facing a shortage of donor corneas, as well as for patients who have poor prognosis with human tissue.

1 June 2016 in Cornea
Verified
Journal Article
Closed access
DWDidrika S. Bsc van de Wouw
Didrika S. Bsc van de Wouw
IMIvanka J. E. van der Meulen
Ivanka J. E. van der Meulen
JVJohannes M. J. Boptom van Vliet
Johannes M. J. Boptom van Vliet
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak
CNCarla P. Nieuwendaal
Carla P. Nieuwendaal
TBThomas J. T. P. van Den Berg
Thomas J. T. P. van Den Berg
Purpose: (1) To qualify complaints of quality of vision in patients with (severe) keratoconjunctivitis sicca by examining straylight values and (2) to check for an effect of scleral lens wear on straylight. Methods: Straylight was measured in 16 patients with severe keratoconjunctivitis sicca using the Oculus C-Quant. In 9 of these patients, scleral lenses were used, and straylight was measured with and without scleral lenses. Other tests included the Schirmer test, visual acuity, the van Bijsterveld score, and a straylight questionnaire. Results: Patients with keratoconjunctivitis sicca had a mean straylight OD of log(s) = 1.36 ± 0.19 SD and OS of log(s) = 1.45 ± 0.17 SD. Mean age was 56 ± 9.3 SD. This was significantly higher than the mean age-matched normal value of log(s) = 1.10 (P < 0.001). Such a straylight increase is functionally significant. The difference in straylight with and without scleral lenses was 0.06 log units ± 0.02 SD, but this was not statistically significant for OD (P = 0.134) and OS (P = 0.293). No correlation was found between straylight and the van Bijsterveld score on the corneal section for OD (P = 0.326) and OS (P = 0.433). Conclusions: Keratoconjunctivitis sicca leads to increased straylight. However, this increase was not correlated to the amount of surface damage graded with the van Bijsterveld score. Further study on the cornea is necessary to determine the source of the increased straylight. Scleral lenses do not have a noteworthy influence on straylight in these patients.

13 January 2025 in Klinische Monatsblätter für Augenheilkunde
Verified
Journal Article
Open access
PDF file
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak
IMIvanka van der Meulen
Ivanka van der Meulen
Background Refractory corneal edema is the foremost reason for endothelial corneal transplantation (EK) in the world. Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) offer good clinical outcomes. However, human donor tissue is limited in availability and has a complex logistical chain. Many patients in need do not have access to EK. Success of the human donor tissue depends on its quality, the number of rebubbles, repeat keratoplasties, and patient-related risk factors. The use of an endothelial corneal keratoprosthesis could benefit patients with a high risk for graft failure and human graft rejection, and patients in underserved areas where tissue banking is unavailable. Patients and Methods Case cohort series of 10 eyes of 10 patients implanted with the EndoArt, with a follow-up of up to 4.5 years. Outcome measures are device adherence, central corneal thickness, visual acuity, and incidence of adverse events. Results In the first seven eyes, the EndoArt was implanted in eyes with low visual potential within the first-in-human (FIH) trial, and in the three remaining eyes, implantation was performed because of either guarded posterior or anterior segment prognosis or the patientʼs wishes. In 9/10 eyes, device adherence was obtained and maintained throughout the follow-up period. Mean corneal thickness decreased from 927 + SD 241 microns to 621 + SD 140 microns. In 6/10 eyes, visual acuity improved from a mean preoperative value of logMAR 1.94 + 0.63 to a mean postoperative value of logMAR 0.8 + 0.64. No pathological thinning or corneal metabolic changes were seen. The surgical technique was developed during the follow-up period. Conclusion The EndoArt provided a stable decrease in central corneal thickness, improved vision in 60% of eyes, and had no device-related adverse events. The EndoArt is an additional treatment modality for special cases like repeat corneal graft failure in the population of the Western world, or as a primary procedure in underserved areas worldwide.

1 January 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
BJBram de Jong
Bram de Jong
IMIvanka J. van der Meulen
Ivanka J. van der Meulen
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak
TBThomas J. van Den Berg
Thomas J. van Den Berg
To study straylight before and after posterior polar cataract removal. Academic Medical Center, Amsterdam, the Netherlands. Prospective case series. Patients diagnosed with posterior polar cataract who agreed to cataract surgery were included in the study. Intraocular straylight was measured before and after surgery with the compensation comparison method using a straylight meter (C-Quant). Measurements were performed on 8 eyes of 4 patients. The mean preoperative corrected distance visual acuity was relatively good (0.15 logarithm of the minimum angle of resolution [logMAR] ± 0.18 (SD). The mean postoperative CDVA was -0.08 ± 0.09 logMAR (P < .01). The mean preoperative straylight was extreme (2.01 ± 0.38 log[s]), 13 times that of a young normal eye; however, it improved postoperatively to 1.04 ± 0.26 log(s) (P < .01). Straylight in eyes with posterior polar cataract patients can be extremely bothersome, while visual acuity is relatively well preserved. Surgery was effective in lowering straylight levels. For these patients, straylight measurements can help objectively measure the quality of vision complaints, and elevated straylight levels can be an indication for surgery independent of visual acuity.