This study was conducted to determine if the thermal degradation of various plastic drinking water pipes (i.e., PEX, HDPE, PP, PVC, and CPVC) may be a source of drinking water contamination. Widespread volatile organic compound (VOC) contamination was found in water distribution systems following three wildfires in California. A potential source of this contamination was thought to be due to the degradation of plastic components in drinking water distribution systems. Eleven plastic drinking water pipes, across eight brands, were exposed to elevated temperatures (200 °C to 400 °C), and subsequently submerged in water or in n-hexane to observe the extent of VOC leaching. Results indicated that thermally damaged drinking water pipes can be sources of VOC leaching, with ten of the eleven materials leaching benzene, a carcinogen, into water. As exposure temperature increased, an increase in VOC leaching was observed in the polyethylene materials. Conversely, in the vinyl materials the significant mass loss associated with high exposure temperature was inversely proportional to the amount of BTEX leaching that was observed. Additional tentatively identified compounds (TICs), consisting primarily of aliphatic hydrocarbons, saturated ketones, or aromatic compounds, were found in the water (22 TICs) and n-hexane (134 TICs) leachate of burned plastics. This study has significant implications for both wildfire and structure fire recovery as plastic materials are increasingly being used in buried and building plumbing, and visual inspection is not a sufficient indicator of contamination risk.
Sunlight photolysis of cysteine and dissolved organic matter (DOM) from freshwater to open ocean water sources generates carbonyl sulfide (COS) but not carbon disulfide (CS2).
1 March 2018 in Environmental Science: Water Research & Technology
Tertiary amines are prevalent in waters due to anthropogenic inputs and are known to enhance organic compound degradation while increasing disinfection by-product (DBP) formation,viathe strong chlorinating agent, R3N–Cl+.
14 May 2020 in Environmental Science: Water Research & Technology
In recent years, cross-linked polyethylene (PEX) pipes have become more commonplace in building plumbing. However, their presence can strongly impact water quality by leaching organic carbon and sorbing contaminants, to and from the water supply, respectively. This study assessed how these processes could further impact concentrations of disinfection by-products (DBPs) and specifically trihalomethanes (THMs) when exposed to chlorinated water. One brand of three different PEX types (PEX-a, PEX-b, and PEX-c) were exposed to synthetic water, which was subsequently chlorinated over 120 h under varying water quality conditions (e.g. temperature, pH, bromide concentration, and free chlorine dose). Results indicated that THM formation was fairly modest for all three PEX types at 22 °C but increased by a factor of ∼2 at 55 °C for the PEX-a pipe. Other water quality conditions exhibited more limited effects. Pipe-storage time strongly affected leached organic carbon levels but did not affect THM formation. THM sorption also occurred for all three PEX types and was similarly controlled by temperature. Sorption data fit well to a kinetic adsorption model. Combined effects of THM formation and sorption at 22 °C generated no aqueous phase THMs, although this effect was not similarly examined at 55 °C. These results suggest that sorption may mitigate the effects of THM formation if PEX pipes continue to reside downstream of where formation occurred, but this may not be the case if other pipe types (e.g. metal pipes) are present. Overall, these findings have important regulatory consequences since current THM monitoring may or may not account for building PEX plumbing.