Stefan Raufer

Stefan Raufer

Auto-generated profile, based on publicly available information

Stefan Raufer

Sonova AG

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2019 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
SRStefan Raufer
Stefan Raufer
JGJohn J. Guinan
John J. Guinan
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
Mammals detect sound through mechanosensitive cells of the cochlear organ of Corti that rest on the basilar membrane (BM). Motions of the BM and organ of Corti have been studied at the cochlear base in various laboratory animals, and the assumption has been that the cochleas of all mammals work similarly. In the classic view, the BM attaches to a stationary osseous spiral lamina (OSL), the tectorial membrane (TM) attaches to the limbus above the stationary OSL, and the BM is the major moving element, with a peak displacement near its center. Here, we measured the motion and studied the anatomy of the human cochlear partition (CP) at the cochlear base of fresh human cadaveric specimens. Unlike the classic view, we identified a soft-tissue structure between the BM and OSL in humans, which we name the CP “bridge.” We measured CP transverse motion in humans and found that the OSL moved like a plate hinged near the modiolus, with motion increasing from the modiolus to the bridge. The bridge moved almost as much as the BM, with the maximum CP motion near the bridge–BM connection. BM motion accounts for 100% of CP volume displacement in the classic view, but accounts for only 27 to 43% in the base of humans. In humans, the TM–limbus attachment is above the moving bridge, not above a fixed structure. These results challenge long-held assumptions about cochlear mechanics in humans. In addition, animal apical anatomy (in SI Appendix) doesn’t always fit the classic view. Significance Basic properties of hearing such as its sensitivity and frequency tuning arise from the mechanical responses in the cochlea. Such responses have been measured extensively in the cochlear base of laboratory mammals, and our understanding of human cochlear mechanics is largely founded on the assumption that cochlear mechanics is similar in all mammals. Here we show that the anatomy and motion of the human cochlear partition differ in crucial ways from the generalized classic view of mammalian cochlear mechanics. Our results call into question this classic view. Establishing the features of human cochlear anatomy and function is important for understanding human hearing and for comparison with results from laboratory animals.

1 August 2022 in Hearing Research
Verified
Journal Article
Open access
MGMohammad Ghoncheh
Mohammad Ghoncheh
SSStefan Stenfelt
Stefan Stenfelt
PMPatrick Maas
Patrick Maas
RSRolf Salcher
Rolf Salcher
NPNils Prenzler
Nils Prenzler
HMHannes Maier
Hannes Maier
The output performance of a novel semi-implantable transcutaneous bone conduction device was compared to an established percutaneous bone-anchored hearing system device using cadaver heads. The influence of actuator position, tissue growth below the actuator and mounting it on the surface or in a flattened bone bed on the performance of the implanted actuator was investigated. The percutaneous and the new transcutaneous device were sequentially implanted at two sites in five human cadaver heads: 55 mm superior-posterior to the ear canal opening (position A) and, closer to the cochlea, about 20 mm inferior-posterior to the ear canal opening behind the pinna on the mastoid (position B). The ipsi- and contralateral cochlear promontory (CP) velocity magnitude responses to percutaneous and transcutaneous stimulation were measured using laser Doppler vibrometry. In addition, the CP vibration of the transcutaneous device placed directly on the skull bone surface was compared with the placement in a flattened bone bed at a depth of about 3 mm. Finally, the influence of placing a thin silicone interposition layer under the implanted transducer was also explored. The percutaneous device provided about an 11 dB higher average CP vibration level than the transcutaneous device at frequencies between 0.5 and 10 kHz. The ipsilateral CP vibration responses with stimulations at position B were on average 13 dB higher compared to stimulation at position A. The placement of the transcutaneous transducer at position B provided similar or higher average vibration magnitudes than the percutaneous transducer at position A. The 3 mm deep flattened bone bed had no significant effects on the output performance. Placing a thin silicone layer under the transcutaneous transducer had no significant influence on the output of the transcutaneous device. Our results using the CP vibration responses show that at frequencies above 500 Hz the new transcutaneous device at position B provides similar output levels as the percutaneous device at position A. The results also indicated that neither a bone bed for the placement of the transcutaneous transducer nor a simulated tissue growth between the actuator and the bone affect the output performance of the device.

12 March 2020 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
SRStefan Raufer
Stefan Raufer
CICornelia Idoff
Cornelia Idoff
AZAleksandrs Zosuls
Aleksandrs Zosuls
GMGiacomo Marino
Giacomo Marino
NBNathan Blanke
Nathan Blanke
HNHideko H. Nakajima
Hideko H. Nakajima

31 October 2019 in Ear & Hearing
Verified
Journal Article
Open access
YCY. Song Cheng
Y. Song Cheng
SRStefan Raufer
Stefan Raufer
XGXiying Guan
Xiying Guan
CHChristopher F. Halpin
Christopher F. Halpin
DLDaniel J. Lee
Daniel J. Lee
HNHideko Heidi Nakajima
Hideko Heidi Nakajima
Objectives: The diagnosis of superior canal dehiscence (SCD) is challenging and audiograms play an important role in raising clinical suspicion of SCD. The typical audiometric finding in SCD is the combination of increased air conduction (AC) thresholds and decreased bone conduction thresholds at low frequencies. However, this pattern is not always apparent in audiograms of patients with SCD, and some have hearing thresholds that are within the normal reference range despite subjective reports of hearing impairment. In this study, we used a human temporal bone model to measure the differential pressure across the cochlear partition (P Diff) before and after introduction of an SCD. P Diff estimates the cochlear input drive and provides a mechanical audiogram of the temporal bone. We measured P Diff across a wider frequency range than in previous studies and investigated whether the changes in P Diff in the temporal bone model and changes of audiometric thresholds in patients with SCD were similar, as both are thought to reflect the same physical phenomenon. Design: We measured P Diff across the cochlear partition in fresh human cadaveric temporal bones before and after creating an SCD. Measurements were made for a wide frequency range (20 Hz to 10 kHz), which extends down to lower frequencies than in previous studies and audiograms. P Diff = P SV- P ST is calculated from pressures measured simultaneously at the base of the cochlea in scala vestibuli (P SV) and scala tympani (P ST) during sound stimulation. The change in P Diff after an SCD is created quantifies the effect of SCD on hearing. We further included an important experimental control—by patching the SCD, to confirm that P Diff was reversed back to the initial state. To provide a comparison of temporal bone data to clinical data, we analyzed AC audiograms (250 Hz to 8kHz) of patients with symptomatic unilateral SCD (radiographically confirmed). To achieve this, we used the unaffected ear to estimate the baseline hearing function for each patient, and determined the influence of SCD by referencing AC hearing thresholds of the SCD-affected ear with the unaffected contralateral ear. Results: P Diff measured in temporal bones (n = 6) and AC thresholds in patients (n = 53) exhibited a similar pattern of SCD-related change. With decreasing frequency, SCD caused a progressive decrease in P Diff at low frequencies for all temporal bones and a progressive increase in AC thresholds at low frequencies. SCD decreases the cochlear input drive by approximately 6 dB per octave at frequencies below ~1 kHz for both P Diff and AC thresholds. Individual data varied in frequency and magnitude of this SCD effect, where some temporal-bone ears had noticeable effects only below 250 Hz. Conclusions: We found that with decrease in frequency the progressive decrease in low-frequency P Diff in our temporal bone experiments mirrors the progressive elevation in AC hearing thresholds observed in patients. This hypothesis remains to be tested in the clinical setting, but our findings suggest that that measuring AC thresholds at frequencies below 250 Hz would detect a larger change, thus improving audiograms as a diagnostic tool for SCD.

1 July 2018 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
SRStefan Raufer
Stefan Raufer
SMSalwa F. Masud
Salwa F. Masud
HNHideko H. Nakajima
Hideko H. Nakajima
The transmission of infrasound within the human ear is not well understood. To investigate infrasound propagation through the middle and inner ear, velocities of the stapes and round window membrane were measured to very low frequencies (down to 0.9 Hz from 2000 Hz) in fresh cadaveric human specimens. Results from ear-canal sound stimulation responses show that below 200 Hz, the middle ear impedance is dominated by its stiffness term, limiting sound transmission to the inner ear. During air-conduction, normal ears have approximately equal volume velocities at the oval (stapes) and round windows, known as a two-window system. However, perturbing the impedance of the inner ear with a superior canal dehiscence (SCD), a pathological opening of the bone surrounding the semicircular canal, breaks down this simple two-window system. SCD changes the volume velocity flow in the inner ear, particularly at low frequencies. The experimental findings and model predictions in this study demonstrate that low-frequency auditory and vestibular sound transmission can be affected by a change in the inner-ear impedance due to a SCD.