18 April 2025 in Nature Biomedical Engineering
Individuals with compromised cochlear nerves are ineligible for cochlear implants and instead rely on auditory brainstem implants (ABIs). Most users of ABIs experience sound awareness, which aids in lip reading, yet not speech intelligibility. Here we engineered a dual-site (brainstem and cortex) implantable system, scaled to macaque anatomy, for the analysis of auditory perception evoked by electrical stimulation of the cochlear nucleus. A soft multichannel ABI, fabricated using thin-film processing, provided high-resolution auditory percepts, with spatially distinct stimulation sites eliciting cortical responses akin to frequency-specific tuning. Behavioural responses collected over several months were sufficiently precise to distinguish stimulations from adjacent channels. Soft multichannel ABIs may aid the rehabilitation of individuals with profound hearing loss who are ineligible for cochlear implants.
31 October 2019 in Ear & Hearing
Objectives: The diagnosis of superior canal dehiscence (SCD) is challenging and audiograms play an important role in raising clinical suspicion of SCD. The typical audiometric finding in SCD is the combination of increased air conduction (AC) thresholds and decreased bone conduction thresholds at low frequencies. However, this pattern is not always apparent in audiograms of patients with SCD, and some have hearing thresholds that are within the normal reference range despite subjective reports of hearing impairment. In this study, we used a human temporal bone model to measure the differential pressure across the cochlear partition (P Diff) before and after introduction of an SCD. P Diff estimates the cochlear input drive and provides a mechanical audiogram of the temporal bone. We measured P Diff across a wider frequency range than in previous studies and investigated whether the changes in P Diff in the temporal bone model and changes of audiometric thresholds in patients with SCD were similar, as both are thought to reflect the same physical phenomenon. Design: We measured P Diff across the cochlear partition in fresh human cadaveric temporal bones before and after creating an SCD. Measurements were made for a wide frequency range (20 Hz to 10 kHz), which extends down to lower frequencies than in previous studies and audiograms. P Diff = P SV- P ST is calculated from pressures measured simultaneously at the base of the cochlea in scala vestibuli (P SV) and scala tympani (P ST) during sound stimulation. The change in P Diff after an SCD is created quantifies the effect of SCD on hearing. We further included an important experimental control—by patching the SCD, to confirm that P Diff was reversed back to the initial state. To provide a comparison of temporal bone data to clinical data, we analyzed AC audiograms (250 Hz to 8kHz) of patients with symptomatic unilateral SCD (radiographically confirmed). To achieve this, we used the unaffected ear to estimate the baseline hearing function for each patient, and determined the influence of SCD by referencing AC hearing thresholds of the SCD-affected ear with the unaffected contralateral ear. Results: P Diff measured in temporal bones (n = 6) and AC thresholds in patients (n = 53) exhibited a similar pattern of SCD-related change. With decreasing frequency, SCD caused a progressive decrease in P Diff at low frequencies for all temporal bones and a progressive increase in AC thresholds at low frequencies. SCD decreases the cochlear input drive by approximately 6 dB per octave at frequencies below ~1 kHz for both P Diff and AC thresholds. Individual data varied in frequency and magnitude of this SCD effect, where some temporal-bone ears had noticeable effects only below 250 Hz. Conclusions: We found that with decrease in frequency the progressive decrease in low-frequency P Diff in our temporal bone experiments mirrors the progressive elevation in AC hearing thresholds observed in patients. This hypothesis remains to be tested in the clinical setting, but our findings suggest that that measuring AC thresholds at frequencies below 250 Hz would detect a larger change, thus improving audiograms as a diagnostic tool for SCD.
5 October 2021 in Otolaryngology–Head and Neck Surgery
During the COVID‐19 pandemic, the utility of portable audiometry became more apparent as elective procedures were deferred in an effort to limit exposure to health care providers. Herein, we retrospectively evaluated mobile‐based audiometry in the emergency department and outpatient otology and audiology clinics. Air conduction thresholds with mobile audiometry were within 5 dB in 66% of tests (95% CI, 62.8%‐69.09%) and within 10 dB in 84% of tests (95% CI, 81.4%‐86.2%) as compared with conventional audiometry. No significant differences were noted between mobile‐based and conventional audiometry at any frequencies, except 8 kHz (P <. 05). The sensitivity and specificity for screening for hearing loss were 94.3% (95% CI, 91.9%‐96.83%) and 92.3% (95% CI, 90.1%‐94.4%), respectively. While automated threshold audiometry does not replace conventional audiometry, mobile audiometry is a promising screening tool when conventional audiometry is not available.
27 February 2023 in Cochlear Implants International
CMCharlotte Morse-Fortier
To compare cochlear implant (CI) data logging of patients with single-sided deafness (SSD) andbilateral sensorineural hearing loss (biSNHL) in various acoustic environments and study the implicatio...
8 February 2024 in Otolaryngology–Head and Neck Surgery