8 February 2018 in International Journal of Architectural Heritage
The 2016 Umbrian earthquake caused the collapse of several medieval churches, while it was noted that ordinary buildings only reported moderate or little damage. Researchers and technicians are looking to these religious constructions with the aim of understanding their structural behavior under seismic action. Depending on the direction of the seismic action, the typical collapse mode was the overturning of the side walls or of the church façade. This often produced the collapse of the roof structure. In many situations, the overturning was facilitated by a weak connection between the load-bearing walls. In this article, the collapse modes of three mediaeval churches are investigated. The article goes into some detail about what considerations are relevant when analyzing a historic masonry construction. The churches object of this study are located in Campi, a hamlet of Norcia, Italy. Between 2000 and 2004, a research team from the Technical University of Milan in collaboration with the Italian Ministry of Culture carried out an extensive investigation on the historic buildings of Campi, providing interesting data about the maintenance level and a summary of the structural state of the churches. These data were used in this article for a critical analysis of the causes of collapse, performed in combination with numerical simulations of the global behavior and local instability.
1 May 2021 in Proceedings of the Institution of Civil Engineers - Structures and Buildings
Historic constructions are common in Europe, but natural hazards can produce significant damage. Shear reinforcement of historic walls, especially in seismic areas, is often necessary and new retrofitting methods have recently been proposed to restore or increase the lateral capacity of shear walls. In this paper the combined use of cross-laminated timber panels and steel wire ropes is proposed to reinforce rubble stone masonry walls with the aim of increasing their lateral load capacity while improving the energy performance of the building envelope. An experimental programme was carried out in the laboratory to assess the mechanical effectiveness of this retrofitting method. The results from a series of quasi-static cyclic shear tests are presented. The test programmes are described and the analysis of test results is included. The potential benefits and limitations regarding the use of the proposed combined method for reinforcing masonry structures are discussed, with an emphasis on the in-plane behaviour.
1 January 2017 in International Journal of Masonry Research and Innovation
The presented research investigates the problem of assessing the seismic resistance of rubble masonry walls to normal lateral forces. Published research on this topic is sparse and reliable data on existing rubble masonry are still lacking. In particular, further studies are required when disconnected rubble walls are rocking out-of-plane with fully cracked sections. This subject was addressed by on-site experimental tests of full-scale elements. The selected case studies are located in Italy, in regions prone to earthquakes, which were sites of devastating seismic sequences in the past. Numerical predictions of the overturning forces and displacements required to cause failures of isolated walls are compared with the results of the quasi-static experiments using force-equilibrium formulations. An improvement in the existing procedures to evaluate masonry vulnerability under seismic loads is presented along with recommendations for the selection of an appropriate level of degradation, especially for rubble works.