Zhaoxu Zhou

Zhaoxu Zhou

Auto-generated profile, based on publicly available information

Zhaoxu Zhou

Wuhan University

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

16 June 2026 in Physica Scripta
Verified
Journal Article
Closed access
ZZZhaoxu Zhou
Zhaoxu Zhou
QLQiying Liu
Qiying Liu
YCYujia Chen
Yujia Chen
YPYufei Peng
Yufei Peng
XWXinyu Wu
Xinyu Wu
FTFeixiang Tang
Feixiang Tang
To address the significant nonlinear mechanical characteristics of silicone adhesives under complex service environments, this study systematically investigates their viscoplastic behavior by combining tensile-shear experiments, theoretical modeling, and numerical simulation. First, based on the frameworks of irreversible thermodynamics and polymer chain dynamics, the Qian-Liu unified viscoplastic constitutive model was employed. Through a step-by-step decoupling strategy, the saturation and back stress evolution parameters were accurately identified, effectively characterizing the kinematic hardening and rate-dependent properties of the adhesive. The comparison results indicate that the Qian-Liu model offers superior physical interpretability and generalization capability compared to the ‘black-box’ neural network, along with reliable predictive accuracy. Furthermore, a UMAT subroutine was developed within the ABAQUS platform to perform structural simulations, verifying the numerical stability of the constitutive integration algorithm. The simulation results revealed a non-uniform stress distribution within the single-lap joint, consistent with Volkersen’s theory, and quantified the secondary bending effect induced by eccentric loading. It was found that the coupling of significant peel stress and shear stress at the interface edges creates a complex mixed-mode stress state. This stress state is identified as the key mechanical mechanism leading to interfacial debonding or cohesive failure of the adhesive layer.

5 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
QSQianyun Shu
Qianyun Shu
QLQiying Liu
Qiying Liu
ZZZhaoxu Zhou
Zhaoxu Zhou
YCYujia Chen
Yujia Chen
STSuilang Tang
Suilang Tang
SLSheng Liu
Sheng Liu
Resonant MEMS sensors operating in harsh fluidic environments demand high sensitivity and structural robustness, which conventional silicon devices often fail to provide. This paper proposes the design and comprehensive multiphysics calibration of a highly sensitive, photothermally actuated MEMS sensor utilizing a porous Cu-Ni functionally graded material (FGM) microcantilever. Rather than traditional power sensing, this study pioneers its application in trace mass sensing, providing a rigorous mass-loading calibration curve ([[EQUATION]]). The device exhibits an exceptional trace mass sensitivity of 25.5 Hz/ng in air and maintains a highly linear responsivity of 8.5 Hz/ng even in heavily damped aqueous environments. Through rigorous topology optimization, a central (O-type) pore distribution is identified as the optimal configuration to capture target molecules near the physical neutral plane, successfully overcoming the traditional mass-stiffness penalty. Furthermore, fluid-structure interaction analyses confirm the sensor's operational integrity in highly viscous fluids (e.g., gasoline and water), retaining significantly higher Q-factors than conventional counterparts. By validating these device-level metrics using the Modified Couple Stress Theory (MCST) and Temperature-Dependent Material Properties (TDMP), the proposed Cu-Ni FGM sensor offers a robust, high-stability paradigm for next-generation in-situ mass detection in harsh environments.

4 March 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
QLQiying Liu
Qiying Liu
ZZZhaoxu Zhou
Zhaoxu Zhou
XWXinyu Wu
Xinyu Wu
YPYufei Peng
Yufei Peng
SSShaonan Shi
Shaonan Shi
SLSheng Liu
Sheng Liu
High-performance resonant mass sensors are increasingly demanded for the trace detection of volatile organic compounds (VOCs) and hazardous gases in environmental monitoring. A critical challenge in current gas sensors is the inherent trade-off between increasing the specific surface area for gas molecule adsorption and maintaining the structural stiffness required for high-frequency resonance. This paper proposes a novel high-sensitivity micro-resonant gas sensor based on a porous functionally graded material (FGM) sandwich microplate. To accurately calibrate the sensor's dynamic response at the micro-scale, a refined mathematical model is established using the Modified Couple Stress Theory (MCST) with a position-dependent material length scale parameter. Furthermore, a multi-objective topology optimization framework based on the Non-dominated Sorting Genetic Algorithm II (NSGA-II) is developed. Rather than using pre-defined porous patterns, the algorithm autonomously aligns the mass-removal regions with the physical neutral surface of the microplate. By maximizing mass reduction in this low-stress region while preserving flexural rigidity, the optimized free-topology design achieves a 29.9% increase in the fundamental frequency compared to conventional O-type designs. This frequency boost directly translates to a significantly enhanced mass responsivity, providing a rigorous theoretical and design foundation for next-generation trace gas measurement devices.