Paige Mass

Paige Mass

Auto-generated profile, based on publicly available information

Paige Mass

Shiekh Zayed Institute Children’s National Hospital Washington DC

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2020 in JMIR Cardio
Verified
Journal Article
Open access
BKByeol Kim
Byeol Kim
YLYue-Hin Loke
Yue-Hin Loke
PMPaige Mass
Paige Mass
MIMatthew R Irwin
Matthew R Irwin
CCConrad Capeland
Conrad Capeland
AKAxel Krieger
Axel Krieger
Background: The complex 3-dimensional (3D) nature of anatomical abnormalities in congenital heart disease (CHD) necessitates multidisciplinary group discussions centered around the review of medical images such as magnetic resonance imaging. Currently, group viewings of medical images are constrained to 2-dimensional (2D) cross-sectional displays of 3D scans. However, 2D display methods could introduce additional challenges since they require physicians to accurately reconstruct the images mentally into 3D anatomies for diagnosis, staging, and planning of surgery or other therapies. Virtual reality (VR) software may enhance diagnosis and care of CHD via 3D visualization of medical images. Yet, present-day VR developments for medicine lack the emphasis on multiuser collaborative environments, and the effect of displays and level of immersion for diagnosing CHDs have not been studied. Objective: The objective of the study was to evaluate and compare the diagnostic accuracies and preferences of various display systems, including the conventional 2D display and a novel group VR software, in group discussions of CHD. Methods: A total of 22 medical trainees consisting of 1 first-year, 10 second-year, 4 third-year, and 1 fourth-year residents and 6 medical students, who volunteered for the study, were formed into groups of 4 to 5 participants. Each group discussed three diagnostic cases of CHD with varying structural complexity using conventional 2D display and group VR software. A group VR software, Cardiac Review 3D, was developed by our team using the Unity engine. By using different display hardware, VR was classified into nonimmersive and full-immersive settings. The discussion time, diagnostic accuracy score, and peer assessment were collected to capture the group and individual diagnostic performances. The diagnostic accuracies for each participant were scored by two experienced cardiologists following a predetermined answer rubric. At the end of the study, all participants were provided a survey to rank their preferences of the display systems for performing group medical discussions. Results: Diagnostic accuracies were highest when groups used the full-immersive VR compared with the conventional and nonimmersive VR (χ22=9.0, P=.01) displays. Differences between the display systems were more prominent with increasing case complexity (χ22=14.1, P<.001) where full-immersive VR had accuracy scores that were 54.49% and 146.82% higher than conventional and nonimmersive VR, respectively. The diagnostic accuracies provided by the two cardiologists for each participant did not statistically differ from each other (t=–1.01, P=.31). The full-immersive VR was ranked as the most preferred display for performing group CHD discussions by 68% of the participants. Conclusions: The most preferred display system among medical trainees for visualizing medical images during group diagnostic discussions is full-immersive VR, with a trend toward improved diagnostic accuracy in complex anatomical abnormalities. Immersion is a crucial feature of displays of medical images for diagnostic accuracy in collaborative discussions.

17 June 2022 in JMIR Cardio
Verified
Journal Article
Open access
BKByeol Kim
Byeol Kim
PNPhong Nguyen
Phong Nguyen
YLYue-Hin Loke
Yue-Hin Loke
VCVincent Cleveland
Vincent Cleveland
XLXiaolong Liu
Xiaolong Liu
AKAxel Krieger
Axel Krieger
Background: Patients with single ventricle heart defects receive 3 stages of operations culminating in the Fontan procedure. During the Fontan procedure, a vascular graft is sutured between the inferior vena cava and pulmonary artery to divert deoxygenated blood flow to the lungs via passive flow. Customizing the graft configuration can maximize the long-term benefits. However, planning patient-specific procedures has several challenges, including the ability for physicians to customize grafts and evaluate their hemodynamic performance. Objective: The aim of this study was to develop a virtual reality (VR) Fontan graft modeling and evaluation software for physicians. A user study was performed to achieve 2 additional goals: (1) to evaluate the software when used by medical doctors and engineers, and (2) to explore the impact of viewing hemodynamic simulation results in numerical and graphical formats. Methods: A total of 5 medical professionals including 4 physicians (1 fourth-year resident, 1 third-year cardiac fellow, 1 pediatric intensivist, and 1 pediatric cardiac surgeon) and 1 biomedical engineer voluntarily participated in the study. The study was pre-scripted to minimize the variability of the interactions between the experimenter and the participants. All participants were trained to use the VR gear and our software, CorFix. Each participant designed 1 bifurcated and 1 tube-shaped Fontan graft for a single patient. A hemodynamic performance evaluation was then completed, allowing the participants to further modify their tube-shaped design. The design time and hemodynamic performance for each graft design were recorded. At the end of the study, all participants were provided surveys to evaluate the usability and learnability of the software and rate the intensity of VR sickness. Results: The average times for creating 1 bifurcated and 1 tube-shaped graft after a single 10-minute training session were 13.40 and 5.49 minutes, respectively, with 3 out 5 bifurcated and 1 out of 5 tube-shaped graft designs being in the benchmark range of hepatic flow distribution. Reviewing hemodynamic performance results and modifying the tube-shaped design took an average time of 2.92 minutes. Participants who modified their tube-shaped graft designs were able to improve the nonphysiologic wall shear stress (WSS) percentage by 7.02%. All tube-shaped graft designs improved the WSS percentage compared to the native surgical case of the patient. None of the designs met the benchmark indexed power loss. Conclusions: VR graft design software can quickly be taught to physicians with no engineering background or VR experience. Improving the CorFix system could improve performance of the users in customizing and optimizing grafts for patients. With graphical visualization, physicians were able to improve WSS percentage of a tube-shaped graft, lowering the chance of thrombosis. Bifurcated graft designs showed potential strength in better flow split to the lungs, reducing the risk for pulmonary arteriovenous malformations.


27 April 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
XLXiaolong Liu
Xiaolong Liu
NHNarutoshi Hibino
Narutoshi Hibino
YLYue-Hin Loke
Yue-Hin Loke
BKByeol Kim
Byeol Kim
PMPaige Mass
Paige Mass
AKAxel Krieger
Axel Krieger
Objective: Fontan surgical planning involves designing grafts to perform optimized hemodynamic performance for the patient’s long-term health benefit. The uncertainty of post-operative boundary conditions (BC) and graft anastomosis displacements can significantly affect optimized graft designs and lead to undesirable outcomes, especially for hepatic flow distribution (HFD). We aim to develop a computation framework to automatically optimize patient-specific Fontan grafts with the maximized possibility of keeping post-operative results within clinical acceptable thresholds. Methods: The uncertainties of BC and anastomosis displacements were modeled using Gaussian distributions according to prior research studies. By parameterizing the Fontan grafts, we built surrogate models of hemodynamic parameters taking the design parameters and BC as input. A two-phase reliability-based robust optimization (RBRO) strategy was developed by combining deterministic optimization (DO) and optimization under uncertainty (OUU) to reduce computational cost. Results: We evaluated the performance of the RBRO framework by comparing it with the DO method in four cases of Fontan patients. The results showed that the surgical plans computed from the proposed method yield up to 79.2% improvement in the reliability of the HFD than those of the DO method ( $p< 0.0001$ ). The mean values of indexed power loss (iPL) and the percentage of non-physiologic wall shear stress (%WSS) for the optimized surgical plans met the clinically acceptable thresholds. Conclusion: This study demonstrated the effectiveness of our RBRO framework to address the uncertainties of BC and anastomosis displacements for Fontan surgical planning. Significance: The technique developed in this paper demonstrates a significant improvement in the reliability of the predicted post-operative outcomes for Fontan surgical planning. This planning technique is immediately applicable as a building block to enable technology for optimal long-term outcomes for pediatric Fontan patients and can also be used in other pediatric and adult cardiac surgeries.

12 May 2023 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
RKRohan N. Kumthekar
Rohan N. Kumthekar
JOJustin D. Opfermann
Justin D. Opfermann
PMPaige Mass
Paige Mass
JCJacqueline M. Contento
Jacqueline M. Contento
CBCharles I. Berul
Charles I. Berul
Background: Pacemaker implantation in infants and small children is limited to epicardial lead placement via open chest surgery. We propose a minimally invasive solution using a novel percutaneous access kit.Objective: To evaluate the acute safety and feasibility of a novel percutaneous pericardial access tool kit to implant pacemaker leads on the epicardium under direct visualization.Methods: A custom sheath with optical fiber lining the inside wall was built to provide intrathoracic illumination. A Veress needle inside the illumination sheath was inserted through a skin nick just to the left of the xiphoid process and angled toward the thorax. A needle containing a fiberscope within the lumen was inserted through the sheath and used to access the pericardium under direct visualization. A custom dilator and peel‐away sheath with pre‐tunneled fiberscope was passed over a guidewire into the pericardial space via modified Seldinger technique. A side‐biting multipolar pacemaker lead was inserted through the sheath and affixed against the epicardium.Results: Six piglets (weight 3.7–4.0 kg) had successful lead implantation. The pericardial space could be visualized and entered in all animals. Median time from skin nick to sheath access of the pericardium was 9.5 (interquartile range [IQR] 8–11) min. Median total procedure time was 16 (IQR 14–19) min. Median R wave sensing was 5.4 (IQR 4.0–7.3) mV. Median capture threshold was 2.1 (IQR 1.7–2.4) V at 0.4 ms and 1.3 (IQR 1.2–2.0) V at 1.0 ms. There were no complications.Conclusion: Percutaneous epicardial lead implantation under direct visualization was successful in six piglets of neonatal size and weight with clinically acceptable acute pacing parameters.

22 February 2022 in Heart Rhythm O2
Verified
Journal Article
Open access
PMPaige N. Mass
Paige N. Mass
JCJacqueline M. Contento
Jacqueline M. Contento
JOJustin D. Opfermann
Justin D. Opfermann
KSKohei Sumihara
Kohei Sumihara
RKRohan N. Kumthekar
Rohan N. Kumthekar
CBCharles I. Berul
Charles I. Berul
Cardiac procedures in infants and children require a high level of skill and dexterity owing to small stature and anatomy. Lower incidence of procedure volume in this population results in fewer clinical opportunities for learning. Simulators have grown in popularity for education and training, though most existing simulators are often cost-prohibitive or model adult anatomy. Develop a low-cost simulator for practicing the skills to perform percutaneous pericardial access and cardiac ablation procedures in pediatric patients. We describe 2 simulators for practicing cardiac procedures in pediatric patients, with a total cost of less than $500. Both simulators are housed within an infant-size doll. The first simulator is composed of an infant-size heart and a skin-like covering to practice percutaneous pericardial access to the heart. Participants obtained sheath access to the heart under direct visualization. The second simulator houses a child-size heart with 7 touch-activated targets to practice manipulating a catheter through a small heart. This can be performed under direct visualization and with 3-dimensional mapping via CARTO. Participants manipulated a catheter to map the heart by touching the 6 positive targets, avoiding the negative target. Physicians-in-training improved their time to complete the task between the first and second attempts. Physicians experienced with the tools took less time to complete the task than physicians-in-training. This inexpensive simulator is anatomically realistic and can be used to practice manipulating procedure tools and develop competency for pediatric cardiac procedures.