Axel  Krieger

Axel Krieger


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 January 2022 in Science Robotics
Verified
Journal Article
Closed access
HSH. Saeidi
H. Saeidi
JOJ. D. Opfermann
J. D. Opfermann
MKM. Kam
M. Kam
SWShuwen Wei
Shuwen Wei
SLS. Leonard
S. Leonard
AKAxel Krieger
Axel Krieger
Autonomous robotic surgery has the potential to provide efficacy, safety, and consistency independent of individual surgeon’s skill and experience. Autonomous anastomosis is a challenging soft-tissue surgery task because it requires intricate imaging, tissue tracking, and surgical planning techniques, as well as a precise execution via highly adaptable control strategies often in unstructured and deformable environments. In the laparoscopic setting, such surgeries are even more challenging because of the need for high maneuverability and repeatability under motion and vision constraints. Here we describe an enhanced autonomous strategy for laparoscopic soft tissue surgery and demonstrate robotic laparoscopic small bowel anastomosis in phantom and in vivo intestinal tissues. This enhanced autonomous strategy allows the operator to select among autonomously generated surgical plans and the robot executes a wide range of tasks independently. We then use our enhanced autonomous strategy to perform in vivo autonomous robotic laparoscopic surgery for intestinal anastomosis on porcine models over a 1-week survival period. We compared the anastomosis quality criteria—including needle placement corrections, suture spacing, suture bite size, completion time, lumen patency, and leak pressure—of the developed autonomous system, manual laparoscopic surgery, and robot-assisted surgery (RAS). Data from a phantom model indicate that our system outperforms expert surgeons’ manual technique and RAS technique in terms of consistency and accuracy. This was also replicated in the in vivo model. These results demonstrate that surgical robots exhibiting high levels of autonomy have the potential to improve consistency, patient outcomes, and access to a standard surgical technique.

24 January 2005 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
AKAxel Krieger
Axel Krieger
RSR.C. Susil
R.C. Susil
CMC. Menard
C. Menard
JCJonathan Coleman
Jonathan Coleman
GFGabor Fichtinger
Gabor Fichtinger
LWLouis Whitcomb
Louis Whitcomb
This paper reports a novel remotely actuated manipulator for access to prostate tissue under magnetic resonance imaging guidance (APT-MRI) device, designed for use in a standard high-field MRI scanner. The device provides three-dimensional MRI guided needle placement with millimeter accuracy under physician control. Procedures enabled by this device include MRI guided needle biopsy, fiducial marker placements, and therapy delivery. Its compact size allows for use in both standard cylindrical and open configuration MRI scanners. Preliminary in vivo canine experiments and first clinical trials are reported.

9 July 2025 in Science Robotics
Verified
Journal Article
Closed access
JKJi Woong (Brian) Kim
Ji Woong (Brian) Kim
JCJuo-Tung Chen
Juo-Tung Chen
PHPascal Hansen
Pascal Hansen
LSLucy Xiaoyang Shi
Lucy Xiaoyang Shi
AGAntony Goldenberg
Antony Goldenberg
AKAxel Krieger
Axel Krieger
Research on autonomous surgery has largely focused on simple task automation in controlled environments. However, real-world surgical applications demand dexterous manipulation over extended durations and robust generalization to the inherent variability of human tissue. These challenges remain difficult to address using existing logic-based or conventional end-to-end learning strategies. To address this gap, we propose a hierarchical framework for performing dexterous, long-horizon surgical steps. Our approach uses a high-level policy for task planning and a low-level policy for generating low-level trajectories. The high-level planner plans in language space, generating task-level or corrective instructions that guide the robot through the long-horizon steps and help recover from errors made by the low-level policy. We validated our framework through ex vivo experiments on cholecystectomy, a commonly practiced minimally invasive procedure, and conducted ablation studies to evaluate key components of the system. Our method achieves a 100% success rate across eight different ex vivo gallbladders, operating fully autonomously without human intervention. The hierarchical approach improved the policy’s ability to recover from suboptimal states that are inevitable in the highly dynamic environment of realistic surgical applications. This work demonstrates step-level autonomy in a surgical procedure, marking a milestone toward clinical deployment of autonomous surgical systems.

25 January 2021 in IEEE Robotics & Automation Magazine
Verified
Journal Article
Closed access
ALAntonio Di Lallo
Antonio Di Lallo
RMRobin Murphy
Robin Murphy
AKAxel Krieger
Axel Krieger
JZJunxi Zhu
Junxi Zhu
RTRussell H. Taylor
Russell H. Taylor
Hao SuHao Su
Hao Su

1 December 2007 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
ASAnurag K Singh
Anurag K Singh
PGPeter Guion
Peter Guion
NSNancy Sears-Crouse
Nancy Sears-Crouse
KUKaren Ullman
Karen Ullman
SSSharon Smith
Sharon Smith
HNHolly Ning
Holly Ning
Background: To assess the feasibility and early toxicity of selective, IMRT-based dose escalation (simultaneous integrated boost) to biopsy proven dominant intra-prostatic lesions visible on MRI. Methods: Patients with localized prostate cancer and an abnormality within the prostate on endorectal coil MRI were eligible. All patients underwent a MRI-guided transrectal biopsy at the location of the MRI abnormality. Gold fiducial markers were also placed. Several days later patients underwent another MRI scan for fusion with the treatment planning CT scan. This fused MRI scan was used to delineate the region of the biopsy proven intra-prostatic lesion. A 3 mm expansion was performed on the intra-prostatic lesions, defined as a separate volume within the prostate. The lesion + 3 mm and the remainder of the prostate + 7 mm received 94.5/75.6 Gray (Gy) respectively in 42 fractions. Daily seed position was verified to be within 3 mm. Results: Three patients were treated. Follow-up was 18, 6, and 3 months respectively. Two patients had a single intra-prostatic lesion. One patient had 2 intra-prostatic lesions. All four intra-prostatic lesions, with margin, were successfully targeted and treated to 94.5 Gy. Two patients experienced acute RTOG grade 2 genitourinary (GU) toxicity. One had grade 1 gastrointestinal (GI) toxicity. All symptoms completely resolved by 3 months. One patient had no acute toxicity. Conclusion: These early results demonstrate the feasibility of using IMRT for simultaneous integrated boost to biopsy proven dominant intra-prostatic lesions visible on MRI. The treatment was well tolerated.

1 January 2008
Verified
Book Chapter
Open access
PDF file
GFGregory S. Fischer
Gregory S. Fischer
AKAxel Krieger
Axel Krieger
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
CCCsaba Csoma
Csaba Csoma
LWLouis Whitcomb
Louis Whitcomb
GFGabor Fichtinger
Gabor Fichtinger
This paper reports an experimental evaluation of the following three different MRI-compatible actuators: a Shinsei ultrasonic motor, a Nanomotion ultrasonic motor and a pneumatic cylinder actuator. We report the results of a study comparing the effect of these actuators on the signal to noise ratio (SNR) of MRI images under a variety of experimental conditions. Evaluation was performed with the controller inside and outside the scanner room and with both 1.5T and 3T MRI scanners. Pneumatic cylinders function with no loss of SNR with controller both inside and outside of the scanner room. The Nanomotion motor performs with moderate loss of SNR when moving during imaging. The Shinsei is unsuitable for motion during imaging. All may be used when motion is appropriately interleaved with imaging cycles.