Spomenka Telišman

Spomenka Telišman

Auto-generated profile, based on publicly available information

Spomenka Telišman

Institute for Medical Research and Occupational Health, Zagreb, Croatia

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2007 in Environmental Research
Verified
Journal Article
Closed access
STSpomenka Telišman
Spomenka Telišman
BČBožo Čolak
Božo Čolak
Alica PizentAlica Pizent
Alica Pizent
JJJasna Jurasović
Jasna Jurasović
PCPetar Cvitković
Petar Cvitković

1 October 2001 in Environmental Research
Verified
Journal Article
Closed access
STSpomenka Telišman
Spomenka Telišman
JJJasna Jurasovića
Jasna Jurasovića
Alica PizentAlica Pizent
Alica Pizent
PCPetar Cvitkovićb
Petar Cvitkovićb

1 January 2000 in Environmental Health Perspectives
Verified
Journal Article
Open access
STSpomenka Telisman
Spomenka Telisman
PCPetar Cvitkovic
Petar Cvitkovic
JJJasna Jurasovic
Jasna Jurasovic
Alica PizentAlica Pizent
Alica Pizent
MGMirjana Gavella
Mirjana Gavella
BRBoris Rocic
Boris Rocic
Blood lead (BPb), activity of delta-aminolevulinic acid dehydratase (ALAD), erythrocyte protoporphyrin (EP), blood cadmium (BCd), serum zinc (SZn), seminal fluid zinc (SfZn), serum copper (SCu), and parameters of semen quality and of reproductive endocrine ...

15 February 2010 in Science of The Total Environment
Verified
Journal Article
Closed access
RSRoel Smolders
Roel Smolders
Alessandro AlimontiAlessandro Alimonti
Alessandro Alimonti
MCM. Cerna
M. Cerna
EHE. Den Hond
E. Den Hond
JKJ. Kristiansen
J. Kristiansen
Greet  SchoetersGreet Schoeters
Greet Schoeters

1 May 2004 in American Journal of Industrial Medicine
Verified
Journal Article
Closed access
PDF file
STSpomenka Telišman
Spomenka Telišman
Alica PizentAlica Pizent
Alica Pizent
JJJasna Jurasovic
Jasna Jurasovic
PCPetar Cvitković
Petar Cvitković

1 January 1993 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
JJJasna Jurasović
Jasna Jurasović
STSpomenka Telišman
Spomenka Telišman
A sensitive method is described for the determination of Pb and Cd in human seminal fluid by electrothermal atomic absorption spectrometry with Zeeman-effect background correction. The method includes deproteinization of seminal fluid with nitric acid, calibration using matrix-matched standards containing a mixture of Pb and Cd and integrated absorbance measurement using a L'vov platform in a non-grooved pyrolytic graphite coated graphite tube. The detection limits (3σ) are 1.4 µg l–1 of Pb and 0.05 µg l–1 of Cd in seminal fluid. The day-to-day precisions (relative standard deviations) of duplicate determinations in 121 samples are in the range 4–14% at 4–48 µg l–1 of Pb and 4–16% at 0.2–3.6 µg l–1 of Cd in seminal fluid. The recoveries (mean ± standard deviation) are 100.6 ± 3.6% of Pb and 98.8 ± 4.2% of Cd and the characteristic mass values are 11.6 pg of Pb and 0.41 pg of Cd, indicating the absence of interferences. Data are presented on the levels of Pb in seminal fluid in normal subjects and those working with Pb and of Cd in seminal fluid in non-smokers and smokers. Corresponding ‘normal values’(median and range) of Pb and Cd in seminal fluid are 8.6 (4.2–16.6)µg l–1 and 0.54 (0.17–1.67)µg l–1, respectively.