Feng Xue

Feng Xue

Auto-generated profile, based on publicly available information

Feng Xue

China Southern Power Grid Energy Research Department Institute, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2024 in Sustainable Cities and Society
Verified
Journal Article
Closed access
YLYue Li
Yue Li
YLYangxi Lv
Yangxi Lv
ZZZixuan Zhang
Zixuan Zhang
XFXue Feng
Xue Feng
XCXudong Chen
Xudong Chen

17 August 2022 in Journal of Environmental Management
Verified
Journal Article
Closed access
XHXuefeng Hu
Xuefeng Hu
XFXue Feng
Xue Feng
CJChaojie Jiang
Chaojie Jiang
MYMina Yang
Mina Yang

1 November 2026 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
YXYuanxing Xia
Yuanxing Xia
LSLinjun Shi
Linjun Shi
KWKe Wang
Ke Wang
AZAlexis Pengfei Zhao
Alexis Pengfei Zhao
FXFeng Xue
Feng Xue
Feng WuFeng Wu
Feng Wu
Existing local energy markets (LEMs) and local flexibility markets (LFMs) in distribution systems are primarily designed to facilitate energy trading and alleviate congestion. However, they lack explicit mechanisms for modeling nodal power deviations, pricing marginal imbalance costs, and allocating fast frequency response. This paper proposes a local imbalance market (LIM) that introduces a node-level imbalance formulation and distribution locational imbalance prices (DLIPs), internalizing network constraints and the balancing costs induced by power imbalances. The LIM incorporates a multi-timescale clearing structure where the distribution system operator (DSO) computes minute-level balancing decisions and DLIPs. A frequency response sensitivity matrix (FRSM) allocates second-scale fast-response costs to the nodes that caused the deviations. A native ADMM-based LIM clearing algorithm is designed to achieve scalable, privacy-preserving coordination among prosumers, aggregators, and the DSO without revealing private information. The second-scale allocation algorithm ensures cost causality and budget consistency through real-time measurement and expost reconciliation. Case studies on three modified distribution networks demonstrate that the proposed LIM enhances balancing efficiency, preserves participant privacy, and achieves accurate cost attribution under renewable uncertainty. The LIM provides a practical and economically consistent pathway for integrating renewable-rich resources into distribution-level market operations.

20 February 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
FXFeng Xue
Feng Xue
CZChen Zuo
Chen Zuo
DLDong Li
Dong Li
DCDezhi Chen
Dezhi Chen
To assure stable cesium injection for negative ion source, the surface ionization detector (SID) is applied for diagnosis. Consisted of emitter and collector, the SID is operating based on bias voltage setting to drive the ionized cesium ions from emitter to the collector for detection. An analysis model of SID for cesium oven evaporation rate is established, investigating the process of cesium transportation in vacuum, thermionic ionization and cesium ion collection. Cesium transportation from nozzle to SID in vacuum is studied on the basis of free molecule flow model, and the cesium density distribution is obtained after having estimated cesium flux density ratio intercepted by SID from nozzle. The collection period is analyzed by particle tracking model, providing the relationship of SID current and ionized cesium current under adaptive bias voltage along with characteristics between SID current and bias voltage reproduced corresponding to experimental results. The model is adjustable and flexible to deal with different 3D structures, geometry and electric field setting. SID analysis for cesium oven of HUST negative ion source is carried out to monitor oven operation and to provide evaporation rate features under various oven temperatures along with error analysis.

6 November 2024 in Nuclear Engineering and Technology
Verified
Journal Article
Open access
FXFeng Xue
Feng Xue
CZChen Zuo
Chen Zuo
DLDong Li
Dong Li
DCDezhi Chen
Dezhi Chen

1 August 2018
Verified
Conference Paper
Closed access
HHHongyi Huang
Hongyi Huang
YHYue Hu
Yue Hu
FXFeng Xue
Feng Xue
DWDongliang Wei
Dongliang Wei
Point discharge is a typical kind of Partial Discharge (PD) behavior. The microscopic process of particle movement is simulated in this paper by combing particle in cell (PIC) method with Monte Carlo collision (MCC) method, which possesses great significance for researching partial discharge. Simulation results show detailed motion process and the Townsend discharge phenomenon. As a result of simulation process, macro characteristics such as PD currents are analyzed to study discharge property. PD current pulse waveform possesses the trend of steep rising edge follows Gaussian distribution while gentle falling edge obeys Power function. The effect of voltage difference, air-gap size and polarity on PD characteristics are discussed in this paper.