This paper investigates the efficient robust design and optimization of a high-temperature superconducting (HTS) linear synchronous motor by using the Taguchi parameter design approach. The manufacturing tolerances of the HTS magnets, primary iron core and the air gap are considered in the robust design to ensure that the optimal design is less sensitive to these uncertainties. To overcome the disadvantages of the conventional Taguchi parameter design approach, a sequential Taguchi robust optimization method is presented for improvement of the motor performance and manufacturing quality. The proposed method is efficient because it holds the advantages of both Taguchi method and sequential optimization strategy. It can significantly increase the average thrust and decrease the thrust ripple of the in-vestigated HTS linear synchronous motor.
The rapid growth of renewable energy and increasing electricity demand pose challenges to the reliability and flexibility of traditional distribution networks. To address these issues, the construction of AC/DC hybrid distribution networks (AC/DC-HDNs) based on existing AC grids has become a promising solution. However, planning the expansion of such networks faces challenges like complex device and line topologies, dynamic fluctuations in distributed generation (DG) and load, and high power electronics costs. This paper proposes a time- and space-integrated expansion planning method for AC/DC-HDNs. The approach builds a distribution grid model based on graph theory, integrating the spatial layouts of AC distribution lines, DGs, main grids, and loads, while capturing dynamic load and renewable energy generation characteristics through time-series analysis. A modified graph attention network (MGAT)-based deep reinforcement learning (DRL) algorithm is used for optimization, balancing economic and reliability objectives. The simulation results show that the modified algorithm outperforms traditional algorithm in terms of both training efficiency and stability, with a faster convergence and lower fluctuation in cumulative rewards. Additionally, the proposed algorithm consistently achieves higher cumulative rewards, demonstrating its effectiveness in optimizing the expansion planning of AC/DC-HDNs.
For an open-type 50 kV A three-dimensional laminated core transformer, this paper establishes a research framework for inter-turn short-circuit faults from the perspective of the power system. First, the B–H curve and magnetostriction curve of the silicon steel sheets were measured using a single-sheet silicon steel magnetostriction measurement system, providing data support for electromagnetic, vibration, and noise analysis. Based on finite element analysis, electromagnetic and vibration characteristics of the three-dimensional laminated core transformer were simulated and analyzed, establishing a steady-state model and verifying its validity. Second, an equivalent circuit model and a finite element model for the transformer winding under inter-turn short-circuit conditions were established. Simulations were conducted to analyze current, leakage magnetic field, and electrodynamic forces. Through simulation, the effects of different short-circuit timings on the transformer’s status were examined, revealing the size and distribution of axial and radial leakage magnetic fields, as well as axial and radial electrodynamic forces under different numbers of shorted turns. Finite element simulation software was used to calculate the magnetic field, vibration, and noise in the three-dimensional laminated core transformer following an inter-turn short circuit. This study delves into the magnetic field, vibration, and noise during normal operation and under varying numbers of shorted turns, analyzing the impact of inter-turn short circuits on the performance and stability of the transformer.
20 June 2022 in IEEE Transactions on Instrumentation and Measurement
DC electronic instrument transformers (DCEIT) are widely used in the voltage source converter based high voltage direct current transmission (VSC-HVDC) system to measure the bus voltage or current, and should be of accurate and quick transient response. The transient performance of the DCEIT need to be calibrated using a calibrator. The existing schemes are difficult to recognize different transient step responses automatically, and usually require human intervention, which limits their flexibility and applicability. Besides, the accuracy of the calculated results is affected by human factors. A self-adaptive algorithm of transient performance analysis is proposed. It recognizes the characteristics of the transient step response based on wavelet analysis, and distinguishes the steady-state and step intervals automatically. Then it evaluates and finds the stable data segments in the steady-state intervals adaptively to calculate the high and low steady-state values. Finally, the data in the step interval are interpolated to search the feature points of the waveform, and then the transient response parameters are calculated according to the coordinates of feature points. In the validation stage, six kinds of step response waveforms are generated by MATLAB to test the performance of the proposed algorithm. Compared with the boundary window method, the proposed algorithm could recognize the characteristics of the tested waveforms automatically and achieve a more accurate analyses of transient performance. In addition, a calibrator prototype based on the proposed algorithm is developed, and some tests are carried out at the National Center for High Voltage Measurement (NCHVM) in China, whose results verify the feasibility of the algorithm.