Dimas Pristovani Riananda

Dimas Pristovani Riananda

Auto-generated profile, based on publicly available information

Dimas Pristovani Riananda

Politeknik Elektronika Negeri Surabaya

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016
Verified
Conference Paper
Closed access
RPR Dimas Pristovani
R Dimas Pristovani
WRW. M. Rindo
W. M. Rindo
BHB. Eko Henfri
B. Eko Henfri
KSK.H. Achmad Subhan
K.H. Achmad Subhan
DPDadet Pramadihanto
Dadet Pramadihanto
Basically Biped robots had to walk like human, to generate this system we use basic approach for analysis human walking behavior. Human walking behavior can be analyzed using Zero Moment Point (ZMP). Zero Moment Point (ZMP) is a zero point which total of gravity forces and horizontal inertia equal 0 (Zero). This paper describes about early step to made basic walking trajectory for FLoW robot. To determine the best Zero Moment Point (ZMP) reference, it can use the comparison of distance and time. From this comparison, the walking characteristic of FLoW robot was found and the best Zero Moment Point (ZMP) trajectory also founded. The basic walking trajectory will generate based on the best Zero Moment Point (ZMP) trajectory as a reference. In the FLoW robot, the best Zero Moment Point Trajectory was founded at distance of 14cm with difference of Zero Moment Point Reference and Real Zero Moment Point equal 0.012cm.

1 November 2017
Verified
Conference Paper
Closed access
RPR. Dimas Pristovani
R. Dimas Pristovani
BHB. Eko Henfri
B. Eko Henfri
DSDewanto. Sanggar
Dewanto. Sanggar
PDPramadihanto. Dadet
Pramadihanto. Dadet
Zero moment point (ZMP) is a mathematical formulation to find a point that causes equilibrium of action and reaction momentum (momentum equal to zero). ZMP can be approached using Single Linear Inverted Pendulum Model (SLIPM). In this paper will explain the modeling of walking trajectory based on the mathematical formulation in SLIPM on the “T-FLoW” humanoid robot. In the SLIPM mathematical equation has 2 main components which are position vector of Center of Mass (CoM) and Acceleration (Linear) of CoM. From these two main compositions, there will be two types of walking trajectory models to be used and implemented in the “T-FLoW” humanoid robot. The first walking locomotion analysis is walking trajectory model the position vector of CoM is dominant. The second walking locomotion analysis is walking trajectory model when the acceleration in CoM is dominant. The results of these two walking trajectory models are for modeling and establishing a control system for robot stability based on dynamic characteristic on both walking trajectory models in the next research.

22 April 2020 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PDF file
HPH. M. Putra
H. M. Putra
MFMuhamad Fikri
Muhamad Fikri
DRD. P. Riananda
D. P. Riananda
GNG. Nugraha
G. Nugraha
MBM. L. Baidhowi
M. L. Baidhowi
RSR. A. Syah
R. A. Syah
One of the problems when designing an aircraft is flight time estimation. When we design the aircraft, in general, calculating the maximum takeoff weight becomes the priority. The longer flight time required by the aircraft, the more batteries should be added. More batteries mean the payload capacity of the aircraft is decreased. On the other hand, adding more weight will increase the requirement of using more powerful motors. We need to take into our account, that using powerful motors should be calculated carefully because the current consumption is also increased. This problem is circling in the same situation, without any real solution to overcome the problem. As unmanned aircraft has become a critical part of human life for example in surveillance, agricultural, and medicine delivery mission, obtaining the optimum and efficient flight time is vital. In this research, we propose a novel approach of maximum takeoff weight calculation that is needed when designing the aircraft by looking at the complete map of motor specifications. The goal of this paper is to help any aircraft user from hobbyist to professional to determine whether their aircraft design is feasible.

1 October 2018
Verified
Conference Paper
Closed access
RPR. Dimas Pristovani
R. Dimas Pristovani
BHB. Eko Henfri
B. Eko Henfri
SDSanggar Dewanto
Sanggar Dewanto
DPDadet Pramadihanto
Dadet Pramadihanto
The main parameters to generate and calculate dynamics system models is position of each joint from its origin position. This paper describes about full body calculation position of each joint based on system design of "T-FLoW" humanoid robot using forward kinematics (FK) analysis. The FK analysis is used to transform the rotational value (degree) of each joint into position vector (cartesian space) of each joint. FK analysis in each joint is combined step by step from its origin until reach the last joint number (end of effector - EoE). The result from this combination is position vector of each joint from its origin. From the result shows the full body FK analysis with homogenous transformation method is represent the real pose of T-FLoW humanoid robot. This full body joint position vector is used to complete the dynamics system model calculation of T-FLoW humanoid robot.

1 February 2019 in International Journal of Electrical and Computer Engineering (IJECE)
Verified
Journal Article
Open access
PDF file
RPR. Dimas Pristovani
R. Dimas Pristovani
DSDewanto Sanggar
Dewanto Sanggar
PDPramadihanto Dadet
Pramadihanto Dadet
Basically, human can sense the active body force trough the soles of their feet and can feel the position vector of zero moment point (ZMP) based on the center of pressure (CoP) from active body force. This behavior is adapted by T-FLoW humanoid robot using unique sensor which is piezoelectric sensor. Piezoelectric sensor has a characteristic which is non-continuous reading (record a data only a moment). Because of it, this sensor cannot be used to stream data such as flex sensor, loadcell sensor, and torque sensor like previous research. Therefore, the piezoelectric sensor still can be used to measure the position vector of ZMP. The idea is using this sensor in a special condition which is during landing condition. By utilizing 6 unit of piezoelectric sensor with a certain placement, the position vector of ZMP (X-Y-axis) and pressure value in Z-axis from action body force can be found. The force resultant method is used to find the position vector of ZMP from each piezoelectric sensor. Based on those final conclusions in each experiment, the implementation of foot pressure sensor modul using piezoelectric sensor has a good result (94%) as shown in final conclusions in each experiment. The advantages of this new foot pressure sensor modul is low-cost design and similar result with another sensor. The disadvantages of this sensor are because of the main characteristic of piezoelectric sensor (non-continuous read) sometimes the calculation has outlayer data.

30 April 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
RPR. Dimas Pristovani
R. Dimas Pristovani
RDRaden Sanggar Dewanto
Raden Sanggar Dewanto
PDPramadihanto. Dadet
Pramadihanto. Dadet
Push recovery is one of humanbehaviorwhich is a strategy to defend the body from anexternal force in any environment. This paper describes push recovery strategy which usesMIMO decoupled control system method. The dynamics system uses aquasi-dynamic system based on triple linear inverted pendulum model (TLIPM). The analysis of TLIPMuses zero moment point (ZMP) calculation from ZMP simplification in last research. By using this simplification of dynamics system, the control design can be simplified into 3 serial SISOwith known and uncertain disturbance models in each inverted pendulum. Each pendulum has different plan to damp the external force effect. In this experiment, PID controller (closed- loop)is used to arrange the damp characteristic.The experiment result shows thatwhen using push recovery control strategy (closed-loop control) is about 85.71% whilewithout using push recovery control strategy (open-loop control) it is about 28.57%.