22 April 2020 in AIP Conference Proceedings
One of the problems when designing an aircraft is flight time estimation. When we design the aircraft, in general, calculating the maximum takeoff weight becomes the priority. The longer flight time required by the aircraft, the more batteries should be added. More batteries mean the payload capacity of the aircraft is decreased. On the other hand, adding more weight will increase the requirement of using more powerful motors. We need to take into our account, that using powerful motors should be calculated carefully because the current consumption is also increased. This problem is circling in the same situation, without any real solution to overcome the problem. As unmanned aircraft has become a critical part of human life for example in surveillance, agricultural, and medicine delivery mission, obtaining the optimum and efficient flight time is vital. In this research, we propose a novel approach of maximum takeoff weight calculation that is needed when designing the aircraft by looking at the complete map of motor specifications. The goal of this paper is to help any aircraft user from hobbyist to professional to determine whether their aircraft design is feasible.
1 February 2019 in International Journal of Electrical and Computer Engineering (IJECE)
Basically, human can sense the active body force trough the soles of their feet and can feel the position vector of zero moment point (ZMP) based on the center of pressure (CoP) from active body force. This behavior is adapted by T-FLoW humanoid robot using unique sensor which is piezoelectric sensor. Piezoelectric sensor has a characteristic which is non-continuous reading (record a data only a moment). Because of it, this sensor cannot be used to stream data such as flex sensor, loadcell sensor, and torque sensor like previous research. Therefore, the piezoelectric sensor still can be used to measure the position vector of ZMP. The idea is using this sensor in a special condition which is during landing condition. By utilizing 6 unit of piezoelectric sensor with a certain placement, the position vector of ZMP (X-Y-axis) and pressure value in Z-axis from action body force can be found. The force resultant method is used to find the position vector of ZMP from each piezoelectric sensor. Based on those final conclusions in each experiment, the implementation of foot pressure sensor modul using piezoelectric sensor has a good result (94%) as shown in final conclusions in each experiment. The advantages of this new foot pressure sensor modul is low-cost design and similar result with another sensor. The disadvantages of this sensor are because of the main characteristic of piezoelectric sensor (non-continuous read) sometimes the calculation has outlayer data.
30 April 2018 in Journal of Physics: Conference Series
Push recovery is one of humanbehaviorwhich is a strategy to defend the body from anexternal force in any environment. This paper describes push recovery strategy which usesMIMO decoupled control system method. The dynamics system uses aquasi-dynamic system based on triple linear inverted pendulum model (TLIPM). The analysis of TLIPMuses zero moment point (ZMP) calculation from ZMP simplification in last research. By using this simplification of dynamics system, the control design can be simplified into 3 serial SISOwith known and uncertain disturbance models in each inverted pendulum. Each pendulum has different plan to damp the external force effect. In this experiment, PID controller (closed- loop)is used to arrange the damp characteristic.The experiment result shows thatwhen using push recovery control strategy (closed-loop control) is about 85.71% whilewithout using push recovery control strategy (open-loop control) it is about 28.57%.