Mehran Abbasi Shirsavar

Mehran Abbasi Shirsavar

Auto-generated profile, based on publicly available information

Mehran Abbasi Shirsavar

Department of Mechanical Engineering, Iowa State University, Ames, IA, 50011, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 February 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Gabriel ClarkeGabriel Clarke
Gabriel Clarke
Brenna HartseBrenna Hartse
Brenna Hartse
AAAmir Ehsan Niaraki Asli
Amir Ehsan Niaraki Asli
MTMehrnoosh Taghavimehr
Mehrnoosh Taghavimehr
NHNiloofar Hashemi
Niloofar Hashemi
Nicole HashemiNicole Hashemi
Nicole Hashemi
Organ-on-chip devices have provided the pharmaceutical and tissue engineering worlds much hope since they arrived and began to grow in sophistication. However, limitations for their applicability were soon realized as they lacked real-time monitoring and sensing capabilities. The users of these devices relied solely on endpoint analysis for the results of their tests, which created a chasm in the understanding of life between the lab the natural world. However, this gap is being bridged with sensors that are integrated into organ-on-chip devices. This review goes in-depth on different sensing methods, giving examples for various research on mechanical, electrical resistance, and bead-based sensors, and the prospects of each. Furthermore, the review covers works conducted that use specific sensors for oxygen, and various metabolites to characterize cellular behavior and response in real-time. Together, the outline of these works gives a thorough analysis of the design methodology and sophistication of the current sensor integrated organ-on-chips.

12 August 2019 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
MAMehdi Ansari
Mehdi Ansari
MGMohammad Golzar
Mohammad Golzar
MBMostafa Baghani
Mostafa Baghani
MAMehran Abbasishirsavar
Mehran Abbasishirsavar
MTMehrnoosh Taghavimehr
Mehrnoosh Taghavimehr
Due to their functional and biological benefits, shape memory polymer (SMP) stents have attracted the attention of researchers in the biomedical science area. The highlights of this article are the evaluation of stent performance including radial force recovery and recovery start temperature (RST) in a constrained state. The effects of polyurethane (PU) mechanical properties and fabrication method are investigated on thermo-viscoelastic properties, sample defect and shape recovery of PU and polycaprolactone (PCL) blend. Thereafter, three tubular stents fabricated with the different diameter to thickness ( d / t ) ratio and their mechanical behavior are examined in loading, relaxation, and unloading. Finally, the radial force recovery of the stents is measured after stimulation in temperatures up to 45 °C. Emerging more peaks in the delta tangent graph implies that samples fabricated with solution-mixing has a better viscoelastic behavior and shows fewer defects compared to the melt-mixing ones. The fabrication method was much more effective on enhancement of the storage and loss modulus compared to double increasing of Young’s modulus of applied PU from 4.3 to 9 MPa. Moreover, an increase in the stent’s d / t from 15 to 10 causes not only an increase in the radial stiffness and force recovery but also leads to the reduction of irreversible deformation and RST. The results of this research reveals the importance of the dimensional and geometric design of SMP stents in controlling the force recovery and RST.

8 October 2018 in Journal of Intelligent Material Systems and Structures
Verified
Journal Article
Closed access
MAM Abbasi-Shirsavar
M Abbasi-Shirsavar
MBMostafa Baghani
Mostafa Baghani
MTM Taghavimehr
M Taghavimehr
MGM Golzar
M Golzar
MNM Nikzad
M Nikzad
DGD George
D George
Shape memory polymer composites have attracted significant attention due to novel properties and great applications. In this article, we focus on the fabrication and simulation of polyurethane/polycaprolactone nanocomposites. The polyurethane/polycaprolactone blends containing ZnO nanoparticles (5 to 30 wt%) are fabricated using a solution mixing and casting method. It is found that significant improvement of polyurethane/polycaprolactone composites in Young’s modulus is achieved by incorporating 20 wt% of ZnO nanoparticles; also, the results of the shape recovery ratio reveal that adding an optimum amount of ZnO (the reinforcement) can increase the shape recovery ratio (for 20 wt% of ZnO). These results could most likely be explained by the fact that some particles restrict the hard segment–soft segment interactions and provide more mobility to polycaprolactone components, while the other nanoparticles can act as the nucleating agent for polycaprolactone chains. A generalized Maxwell model is then used to examine the shape memory behavior of shape memory polymer composites. The dynamic mechanical thermal analysis results are utilized to define the model coefficients and the simulation is carried out to determine the shape recovery ratio. Simulation of this shape recovery ratio for shape memory polymer composites reveals that the numerical results are in good agreement with those of the experimental data.

23 May 2022 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MSMehran Abbasi Shirsavar
Mehran Abbasi Shirsavar
MTMehrnoosh Taghavimehr
Mehrnoosh Taghavimehr
LOLionel J. Ouedraogo
Lionel J. Ouedraogo
MJMojan Javaheripi
Mojan Javaheripi
Nicole HashemiNicole Hashemi
Nicole Hashemi
Reza MontazamiReza Montazami
Reza Montazami

20 September 2021 in Nanotechnology
Verified
Journal Article
Closed access
SASteven De Alwis
Steven De Alwis
MSMehran Abbasi Shirsavar
Mehran Abbasi Shirsavar
SSSarabjit Singh
Sarabjit Singh
Nicole HashemiNicole Hashemi
Nicole Hashemi
A scalable manufacturing method for the production of biocompatible fewlayered graphene nanosheets is developed using hydrodynamic cavitation. Scalable exfoliation is induced by employing hydrodynamic cavitation and a serum albumin protein. Unlike acoustic cavitation, the primary means of bubble collapse in hydrodynamic cavitation is caused laterally, thereby separating two adjacent flakes through a shear effect. In this process, bovine serum albumin, a known protein, was employed to act as an effective exfoliation agent and provide desired stability by preventing restacking of the graphene layers. This method was used to study the effect of time of graphene exfoliation in a novel hydrodynamic cavitation system. The fabricated products were characterized using Raman spectroscopy, Transmission electron microscopy, Fourier transform infrared spectroscopy and differential scanning calorimetry. The results showed that with increasing the time of exfoliation, the number of graphene layers decreased based on theI2D/IGratio but disorder increased based on theID/IGratio. At 3 h, theI2D/IGratio was at 0.39 and theID/IGratio was 0.25, while at 6 h theI2D/IGratio was 0.35 andID/IGratio was 0.29. The results of the theoretical and computational analysis this research outlines are needed to obtain an effective cavitation model that can be used to potentially improve graphene synthesis and quality. The captured images of bubble propagation in the solution imply that this fluidic phenomenon could assist the graphene exfoliation. To prove this, a simple cavitation model using a needle valve was designed. The needle valve cavitation setup was able to identify that cavitation assists in graphene exfoliation and this was proved using the graphene characterization data. Based on these findings, the simulation models were designed in ANSYS and COMSOL. Specifically, through the ANSYS simulation, we were able to calculate cavitation numbers for specific flow rates and fluid temperatures.

19 May 2022 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
MSMehran Abbasi Shirsavar
Mehran Abbasi Shirsavar
AAAmir Ehsan Niaraki Asli
Amir Ehsan Niaraki Asli
Nicole HashemiNicole Hashemi
Nicole Hashemi
Dopamine is critical for the physiological function and plays a crucial role in the discovery of neurological disorders such as Parkinson's disease. Improving the measurement of this neurotransmitter could improve treatment, diagnosis, and prognosis of neurological disorders. Graphene's outstanding biocompatibility and electrical conductivity have caused it to become a widely used material in cellular interfacing and neurotransmitter characterization. However, graphene has been rarely used to investigate cellular systems after introducing trauma. Sensing dopamine on the cellular level and on the microscale can lead to provide a point-of-care diagnostics for traumatic brain injury patients. The sensitivity of graphene biosensor to different concentrations of dopamine was evaluated in the dynamic range of 0.1–100 µM, and the limit of detection of biosensor was estimated to be 180 µM. In this work, a 3D-printed graphene biosensor was used to characterize the dopamine levels as a real-time detector of neurotransmitters. We used cyclic voltammetry (CV) to measure the response of graphene biosensors to neurotransmitter changes, in addition, to evaluate the effect of UV irradiation as the injury stimulant on the electrical properties of graphene biosensors. We demonstrated that the 3D-printed graphene could detect significant changes in the CV profiles of N27 dopaminergic neural cells cultured on the graphene device in the face of trauma.