12 April 2017 in IEEE Transactions on Automation Science and Engineering
This paper presents a time efficient finite-control-set model predictive control (FCS-MPC) scheme for the doubly fed induction generator system. In this scheme, the switching states of the rotor side converter are directly taken as control inputs. This way, the optimized control action can be directly applied to the converter. Compared with the existing FCS-MPC approaches, the salient feature of the proposed scheme is the reduction of the computation time. By introducing a set of augmented decision variables, the original intractable binary quadratic programming problem in FCS-MPC can be analytically transformed to a binary linear programming problem, which can be solved efficiently. By this means, the computation time of the proposed scheme is much less than that of the existing schemes. This reduction in computation time enables FCS-MPC with longer prediction horizons, thus yielding better control performance.
26 February 2019 in IEEE Transactions on Power Systems
The injection of a significant amount of wind power tends to increase the rate of change of the grid frequency. Therefore, it is a trend for wind farm to participate in the grid frequency regulation. However, during the frequency control process, individual wind generators in a wind farm may prone to instability due to possible over-deceleration. To address this issue, this paper presents a new nonlinear model predictive control (NMPC) scheme for the wind farm frequency response. By incorporating the nonlinear dynamics of each individual wind generator into the NMPC design, it achieves both objectives of dynamically optimal frequency response and wind generator stability. This scheme has a three-layer structure. Based on the linear model predictive control and moving horizon estimation, a top-layer controller computes the overall wind farm power reference to support the frequency control. This overall power reference is fed to the middle- layer NMPC, and is further distributed among multiple wind generators. The dispatched power references are then sent to the bottom-layer wind generators local controllers for execution. Simulation results verify the effectiveness of the proposed scheme.
13 March 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
As the most common fault of permanent magnet synchronous motor, inter-turn short circuit fault has great harm and develops rapidly. Once it is not diagnosed in time, it will bring secondary damage to the motor system. In the process of early fault diagnosis, the harmonic of the motor often increases the difficulty of fault feature extraction. In order to improve the reliability of the system, a method for early inter-turn short circuit diagnosis of permanent magnet synchronous motors based on data-driven digital twin models is proposed in this paper. Firstly, the three-phase current residuals of the permanent magnet synchronous motor under inter-turn short circuit fault are analyzed theoretically. Secondly, the digital twin model of the target motor in healthy states is established through NARX(Nonlinear Auto-Regressive model with Exogenous Inputs) network. Finally, the early short circuit diagnosis is completed through the analysis of the three-phase current residual. The method proposed in this paper does not need fault data and can complete the diagnosis of minor faults under the condition of large harmonic and certain inherent asymmetry. It has high sensitivity and obvious fault characteristics. Theoretical derivation and experiments verify the effectiveness of the proposed method.
9 March 2018 in IEEE Transactions on Energy Conversion
DC collection grid and high-voltage direct-current (HVDC) transmission lines provide promising solutions for offshore wind farms (OWF). However, due to the decoupling effect of the dc collection grid and HVDC link, an HVDC-connected dc-grid OWF cannot directly participate in the frequency regulation of the onshore ac grid. To address this issue, this paper presents a communication-free control scheme, which allows an HVDC-connected all-dc OWF to contribute to the onshore ac grid fre-quency regulation. This scheme consists of making the offshore dc collection grid voltage and onshore frequency deviations pro-portional. It relies on the HVDC voltage control at the onshore converter, together with the dc collection grid voltage control at the offshore converter. Furthermore, by continuously adjusting the droop of each wind generator in response to its local wind speed, this scheme takes into account the wind speed difference among wind generators, thereby improving the frequency nadir / peak and guaranteeing the wind generator stability. Simulation results verify the effectiveness of the proposed scheme.
8 November 2019 in IEEE Transactions on Sustainable Energy
2 September 2022 in IEEE Transactions on Power Electronics
Harmonics and drifts are found in the position estimation errors of high-frequency signal injection (HFI) methods. To suppress the position estimation error, a hybrid active flux observer with disturbance rejection for both HFI method and model-based method is proposed. It fuses the position information from traditional HFI method and model-based method as the input of a disturbance observer, the estimated disturbance output can compensate measurement error for the two methods. Then a reduced-order natural speed observer is connected in a cascaded form to reject motor mechanical disturbance by estimating the load torque. Besides, a stator resistance identification algorithm is proposed, which is proved stable near zero frequency under persistent excitation condition. A tuning guideline for the whole algorithm is elaborated based on a rigorous stability analysis. Effective experiments and simulations verify the feasibility of the proposed scheme on a 0.75-kW interior permanent magnet synchronous motor drive platform.