Zhichao Chen

Zhichao Chen

Auto-generated profile, based on publicly available information

Zhichao Chen

State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZCZhichao Chen
Zhichao Chen
DLDeliang Liang
Deliang Liang
SJShaofeng Jia
Shaofeng Jia
LYLin Yang
Lin Yang
SYShuzhou Yang
Shuzhou Yang
As the most common fault of permanent magnet synchronous motor, inter-turn short circuit fault has great harm and develops rapidly. Once it is not diagnosed in time, it will bring secondary damage to the motor system. In the process of early fault diagnosis, the harmonic of the motor often increases the difficulty of fault feature extraction. In order to improve the reliability of the system, a method for early inter-turn short circuit diagnosis of permanent magnet synchronous motors based on data-driven digital twin models is proposed in this paper. Firstly, the three-phase current residuals of the permanent magnet synchronous motor under inter-turn short circuit fault are analyzed theoretically. Secondly, the digital twin model of the target motor in healthy states is established through NARX(Nonlinear Auto-Regressive model with Exogenous Inputs) network. Finally, the early short circuit diagnosis is completed through the analysis of the three-phase current residual. The method proposed in this paper does not need fault data and can complete the diagnosis of minor faults under the condition of large harmonic and certain inherent asymmetry. It has high sensitivity and obvious fault characteristics. Theoretical derivation and experiments verify the effectiveness of the proposed method.

9 May 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
ZCZhichao Chen
Zhichao Chen
DLDeliang Liang
Deliang Liang
SJShaofeng Jia
Shaofeng Jia
SYShuzhou Yang
Shuzhou Yang
The diagnosis of numerous defects in permanent magnet synchronous motors is crucial to the motor system's safe operation. However, fluctuating working conditions can distort current waveforms, making defect diagnosis more difficult. In addition, the closed-loop controller influences the faulty components of current signals. This article proposes a model-based data normalization method to convert raw current data into a standard format in order to address the issue. In this article, the mathematical model is presented under both healthy and different faulty conditions. Luenberger observer is constructed to calculate the current estimation error between the actual motor and the constructed model. The error under interturn short-circuit fault, uniform demagnetization fault, and partial demagnetization fault is theoretically demonstrated as a proof of the effectiveness of the approach. Then, the error is further normalized to eliminate the influence of speed on both signal amplitude and fundamental frequency. The method proposed eliminates the influence of working conditions and controller bandwidth on current signals. After the whole process, the data can be processed to be almost only related to the fault type and fault severity. The effectiveness of the proposed method is verified by theoretical derivation, simulation, and experimentation.

22 November 2024 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
ZCZhichao Chen
Zhichao Chen
ZLZhe Liang
Zhe Liang
DLDeliang Liang
Deliang Liang
SJShaofeng Jia
Shaofeng Jia
As one of the most widespread faults in permanent magnet synchronous motors (PMSM), demagnetization faults can dramatically degrade the performance of the motor system. Extensive research has been conducted on partial demagnetization faults in existing literature, providing the harmonic range of the back electromotive force (EMF) when demagnetization faults occur. In order to enhance the specificity of fault characteristics in practical application scenarios, this paper analyzes the characteristic faulty signature associated with motor topologies in the back EMF and currents for fractional slot PMSMs experiencing partial demagnetization faults. The back EMF reduction model under faulty conditions is constructed. An analysis is conducted on the specific faulty harmonic components of PMSMs with three distinct pole-slot combinations, using the dq-axis reference frame. The research reveals that in concentrated winding fractional slot PMSMs, the specific harmonic order of partial demagnetization fault in the dq-axis is determined by the ratio of the number of slots to the number of pole pairs. The effectiveness of the proposed conclusion is validated by finite element (FE) simulation and experiment results.

27 October 2022 in IET Power Electronics
Verified
Journal Article
Open access
ZCZhichao Chen
Zhichao Chen
DLDeliang Liang
Deliang Liang
SJShaofeng Jia
Shaofeng Jia
SYShuzhou Yang
Shuzhou Yang
LYLin Yang
Lin Yang
In the industry, there is still a substantial amount of old in‐service equipment without a fault warning function. To provide an effective fault monitoring scheme for the in‐service motor drive system inside the equipment, this paper proposes a fault diagnosis method based on the DC‐link current at the power side, which can complete the fault monitoring task only outside the equipment without disassembly and assembly of the equipment and the inside installation of sensors. The effect of open‐circuit faults on DC‐link current is thoroughly examined and classified into four classes. To locate the faulty switching component of voltage‐source‐inverter (VSI), one electric period of DC‐link current is split into six regions according to the current vector position. And the relationship between current vector regions, fault signatures, and fault locations is summarized. Additionally, a low‐pass filter is used to smooth the DC‐link current and reduce the bandwidth limit of current sensors. Open circuit faults can be detected and located by identifying the fault signature in the DC‐link current and rotor position. Finally, the effectiveness and robustness of the proposed method are verified by experiment results.

2 October 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YWYuheng Wang
Yuheng Wang
DLDeliang Liang
Deliang Liang
ZLZhe Liang
Zhe Liang
YLYang Liang
Yang Liang
ZCZhichao Chen
Zhichao Chen
This article proposes a novel robust method for identifying the moment of inertia of rotor shaft in surface-mounted permanent magnet synchronous motor servo systems. Superior to conventional approaches, this method enables stable identification under current control loop or poorly tuned speed loop, and can identify the moment of inertia using low-amplitude speed injection as small as 0.5 rad/s (4.8 r/min), while maintaining minimal errors. The method is based on sinusoidal signal injection and identifies the moment of inertia by analyzing the phase difference between the estimated load torque and motor speed. This approach provides a reliable one-time parameter calibration, largely insensitive to the influence of unknown disturbances, including Stribeck friction, nonlinear load, and speed quantization errors. This method can be applied to rapid autotuning of speed loop and online moment of inertia identification with low-amplitude injection, providing a foundation for high-performance control algorithms. Experimental results validate these characteristics.