Alexander Novitskiy

Alexander Novitskiy

Auto-generated profile, based on publicly available information

Alexander Novitskiy

Power Systems Department, Faculty of Electrical Engineering and Information Technology at the Ilmenau University of Technology, P.O.B. 100565, D-98684, Ilmenau, Germany

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2012
Verified
Conference Paper
Closed access
ANAlexander Novitskiy
Alexander Novitskiy
DWDirk Westermann
Dirk Westermann
The sharing of the routes for transmission overhead lines operated at different voltages and frequencies is a popular technical solution. Often the circuits of extra high and high voltage lines are installed on the same towers. This causes the electromagnetic interaction between corresponding power transmission systems. Earth fault currents and neutral point displacement voltages can be increased in electrical networks with resonant earthed neutral due to the electromagnetic influence from parallel located power transmission lines. Theoretical mechanism of the interaction, some practical examples based on investigations in German transmission networks and possible measures for the reduction of negative influences will be considered in the offered paper.

1 June 2005
Verified
Conference Paper
Closed access
HSH. Schau
H. Schau
ANA. Novitskiy
A. Novitskiy
The localization of the dominant harmonic distortion source in the electrical network is one of the practical tasks in the consideration of the power quality in electric power systems. The conventional methods of the estimating of the impacts of the utility and the customer to the harmonic distortion at the network node are the harmonic power flow analysis as well as the correlation analysis of the harmonic voltage and current phasors. The practical use of both methods is discussed below by means of the example of the identification of the dominant harmonic source in the LV supply feeder of an industrial consumer. Based on the analysis carried out it is shown that the direction of harmonic active power flows is a more common and reliable criterion in comparison with the correlation analysis for the identification of dominant harmonic sources in electric power systems.

1 June 2014
Verified
Conference Paper
Closed access
IKIrina Konotop
Irina Konotop
ANAlexander Novitskiy
Alexander Novitskiy
DWDirk Westermann
Dirk Westermann
The use of the same right of way for several power lines is a popular technical solution nowadays. The drawback of this solution is the growth of interferences between nearby power circuits of transmission lines, especially in the case of multi-circuit lines positioned on the same pylons. Neutral voltage displacement in the network with resonant earthing caused by the influence of nearby power line is one of known effects of the interaction. The efficiency of the use of local compensation of neutral voltage displacement in the 110 kV resonant earthed network containing the 21 km segment of combined 380/110 kV overhead line is studied in the offered paper. It is shown that the voltage displacement influenced by the combined overhead line can be propagated over full 110 kV network containing several thousand km of overhead transmission lines. Taking into account the earth fault protection requirements it is shown that local compensation devices are not always capable to reduce the neutral voltage displacement down to the permissible level. Possible practical measures for the reduction of the influenced neutral voltage displacement are discussed in the paper.

18 October 2021
Verified
Conference Paper
Closed access
ANAlexander Novitskiy
Alexander Novitskiy
SSSteffen Schlegel
Steffen Schlegel
DWDirk Westermann
Dirk Westermann
The development of modern LV distribution networks is characterized by the growth in the number of converter-interfaced prosumers using electronic elements with switching frequencies in the kHz range. It causes the emission of so-called “supraharmonics” into electrical networks. For the analysis of the propagation of supraharmonics it is necessary to known the corresponding frequency-dependent parameters of LV distribution lines. Modern LV distribution lines are mainly cable lines and designed for the operation at the fundamental frequency (e.g. 50 Hz). The calculation of line impedances at all other frequencies is the subject of special studies. The paper deals with the analysis of positive sequence series impedances of LV sector-shaped cables in the frequency range 2 to 9 kHz. The analysis is based on FEM simulation results. Novel formulas are suggested for the simplified determination of series resistances and inductances of LV 4-core cables with sector-shaped aluminium conductors.