Arun Kumar Kalidass

Arun Kumar Kalidass

Auto-generated profile, based on publicly available information

Arun Kumar Kalidass

Department of Mechanical Engineering, Karpagam College of Engineering, Coimbatore, Tamil Nadu, India

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2024 in Journal of Studies in Science and Engineering
Verified
Journal Article
Open access
PDF file
MYM. Yuvaperiyasamy
M. Yuvaperiyasamy
N. SenthilkumarN. Senthilkumar
N. Senthilkumar
BDBalakrishnan Deepanraj
Balakrishnan Deepanraj
SRSuresh Kumar Ramalingam
Suresh Kumar Ramalingam
AKArun Kumar Kalidass
Arun Kumar Kalidass
Solar distillation converts salt water into drinkable water, requiring minimal maintenance and energy-saving. However, the desalination process has drawbacks because the system's slow evaporation and condensation rate leads to low freshwater output. Consequently, this method is not widely utilized due to its limited productivity. To address this issue, the study's primary aim was to enhance the productivity of the single-slope solar still. This was achieved by altering the water depth from 3 cm to 6 cm and incorporating an external reflector. The experiments were conducted in Coimbatore, Tamil Nadu, India (11.0168° N, 76.9558° E), with a condensing cover inclined at 11 degrees. The research occurred on varying days between October and November 2023, with water depths ranging from 3 to 6 cm. A comprehensive analysis investigated the influence of different factors on daily production, such as ambient temperature, solar intensity, and inner and outer glass temperatures. The experimental results indicate that the solar still with a single basin, operating at a water depth of 3 cm, achieved the highest water productivity (2.68 L/day) and displayed the best efficiency (30.52%) compared to 4, 5, and 6cm depths. Furthermore, incorporating an external reflector into the solar system still demonstrated a notable elevation in temperature, resulting in a significant boost in water productivity of 3.085 liters per day. This improvement also led to an increase in efficiency of 35.1%.

8 July 2026 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
KKKalidass Arun Kumar
Kalidass Arun Kumar
DSDHARANI KUMAR SELVAN
DHARANI KUMAR SELVAN
NRN. Mohammed Raffic
N. Mohammed Raffic
This study investigated the biocompatibility and wear behaviour of cobalt chromium (CoCr) alloy fabricated using selective laser melting (SLM). A combination of Taguchi L 16 experimental design and multi-criteria decision making (MCDM) methods was employed to analyze the effects of wear parameters, such as load, speed, and time. Optimization was performed with respect to the weighting of criteria using a method based on the removal effect of criteria (MEREC) and multi-attribute border approximation area comparison (MABAC) for ranking the alternatives. The findings indicated that the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay on MG-63 osteoblast-like cells showed excellent cell viability, confirming the biocompatibility of the 3D-printed CoCr alloy. Antibacterial tests indicated a cell viability of 83.4% on the alloy, leading to a stable Cr 2 O 3 passive oxide layer, confirming its suitability for implants. Subsequently, the wear parameter was augmented, and an analysis of variance (ANOVA) was performed to determine the most influential parameter in the wear behaviour at a confidence interval of 95%. The optimal process parameters that enhanced the biological and tribological characteristics of the 3D-printed alloy were a load of 20 N, speed of 600 rpm, and time of 45 min (Trial 2). These resulted in a minimum wear rate of 1.16 × 10 −6 mm 3 /Nm, friction force of 3 N, coefficient of friction (CoF) of 0.05, and average surface roughness of 1.88 µm. The improvements in the wear rate, friction force, CoF, and surface roughness were 12.2%, 13.04%, 12.5%, and 7.84%, respectively, when compared to the worst parameter (Trial 12). Also, the low current density (I) over the potential voltage (V) indicating corrosion resistance was in electrochemical corrosion testing. Wear analyses showed that ploughing tracks, grooves due to adhesive wear, and subsurface crack initiation due to fatigue were induced on the worn surface. This combined biological and tribological assessment provides significant insights for the design and optimization of implants.