Chia-Ming Hung

Chia-Ming Hung

Auto-generated profile, based on publicly available information

Chia-Ming Hung

Department of Electrical Engineering, National Cheng Kung University , Tainan City 70101, Taiwan

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 May 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CCChia-Jung Chang
Chia-Jung Chang
CTCheng‐Chi Tai
Cheng‐Chi Tai
FLFang-Wei Lin
Fang-Wei Lin
CKChung-Ching Kuo
Chung-Ching Kuo
CHChia-Ming Hung
Chia-Ming Hung
This paper presents a newly developed flexible laminated copper coil (FLC) for electromagnetic thermotherapy that has several advantages over traditional hard copper coils. We study the effect of pitch (the distance between coil turns) on the heating performance of the proposed FLC coil. The flexible coil can be wound into different shapes for various purposes. However, the output power of the heating system can be substantiality affected by the coil inductance. This study is aimed toward reducing coil inductance by changing the original flexible coil diameter and pitch in order to enhance the output power of a high-frequency machine, improve treatment, and meet the actual heating requirements. The results of the experiments show that the temperature is six times better when using the flexible coil as compared to when using the traditional hard copper coil, where adjusting the coil pitch can increase the needle temperature by a maximum of 48.3°C in pork liver tissue. In addition, this study simulates distribution of the magnetic field of the flexible coil via a finite element analysis and explores the coil design and heating effect of metal needle heating and liver tissue ablation. The improved features of this proposed method are threefold: (1) The flexible coil can be used to treat different zones of the human body. (2) The flexible coil exhibits better heating performance than a hard copper coil. (3) The coil inductance is lowered, and power is improved, which in turn, leads to better treatment and meets the actual heating requirements.

1 May 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
CHChia-Ming Hung
Chia-Ming Hung
CTCheng-Chi Tai
Cheng-Chi Tai
The heated metal needle used for tumor thermotherapy is considered crucial for enhancing the practicality of cauterization using electromagnetic induction-heating techniques. In this study, a novel coil capable of producing a deep magnetic field is designed. In the proposed design, the coil structure is improved to enhance the intensity of the coil’s deep magnetic field and its suitability for deep-tissue cauterization. Furthermore, a series of experiments are conducted using a single and consistent input current. The heating experiments are conducted at varying depths by placing the needle beneath the coil. The proposed coil significantly increases the induction-heating temperature and provides a solution to the long-standing problem of insufficient needle temperature. This research has also improved the usability of the induction-heating equipment in the field of deep tumor ablation.